1 q t i PF2D540 o !0 u !0 !2ywr e !
9 e r t q !3 w !0 @3 @2 !1 !2 !5 !4 y u i o @1 @0 !8 !6 Component Parts Component Parts No. No. Qty Description Material Remarks Description Material Remarks Qty 1 1 Brass Electroless nickel plated Aluminum alloy White anodized Rod cover Cushion spear A q o 1 1 Brass Electroless nickel plated Aluminum alloy White anodized Head cover Cushion spear B w !
9 e r t q !3 w !0 @3 @2 !1 !2 !5 !4 y u i o @1 @0 !8 !6 Description Material Note Component Parts Qty. No. No. Description Material Note Qty. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 1 Rod cover Aluminum alloy Rod seal A NBR White anodized q !
Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. q Symbol Description Body size 20 40 60 30 Nil K Note 1) Without backflow function With backflow function With backflow function w + Nil N Note 2) F Note 3) Thread type Rc NPT G e + 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Port size r + Nil B Note 5) H Note 4) a Without mounting option
ID Construction IDG SFD101-02 SFD102-02 IDK w q r t e q r e w AMG AFF AM AMD AMH Component Parts Component Parts No. Description Note Material Aluminum alloy No.
Applicable manifold base Plug-in type With attachment plug lead wire: Type 51G Description Component parts Manifold block u, Junction box i, Lead wire assembly o Tie-rod y, O-ring e, r, Seal A q VVZS2000-1A-1-Port size (1) Manifold block assembly Manifold block u, Tie-rod y, O ring e, r, Seal A q Non plug-in type: Type 51 VVZS2000-1A-2-Port size (1) Plug-in type With D-sub connector: Type
Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical entry P Port size Model Grommet: G Conduit: C Conduit terminal: T M L K H F E D C B N A U S R Q R Q R Q M4 12.8 14 28 12.5 6.5 31 64 28 4.5 13.5
-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 L L VXA K VN K Conduit terminal: T LVC LVA F (Q) 34 LVH LVD LVQ 25 U LQ R C LVN G1/2 TI/ TIL E B A H D 2-P Port size (S) PA 2-M Thread depth N PAX L PB K (mm) Electrical entry P Port size B C A D E F H K L M N Grommet:G Conduit:C Conduit terminal:T Model Q R Q R Q R S U 13.5 28 64 1/8 31 6.5
Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical entry P Port size Model Grommet: G Conduit: C Conduit terminal: T M L K H F E D C B N A U S R Q R Q R Q M4 12.8 14 28 12.5 6.5 31 64 28 4.5 13.5
ASD Model Meter-out type Rod and applicable tubing O.D. 4 6 8 10 Meter-in type AS1000P-04-04 AS2000P-04-04 AS2000P-06-06 AS2500P-06-06 AS3000P-08-08 AS3000P-10-10 AS1010P-04-04 AS2010P-04-04 AS2010P-06-06 AS2510P-06-06 AS3010P-08-08 AS3010P-10-10 AS AS-FE KE
When the ambient temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.
Metric size*1 Inch size*1 Type 02 2*3 23 3.2*2 04 4 06 6 01 1/8" 03 5/32" 2 Elbow Control type*1 0 Meter-out 1 Meter-in *1 Metric size: Light gray Inch size: Orange *1 Meter-out and meter-in types can be visually identified by the color of the knob. Meter-out: Gray Meter-in: Light blue *2 Use 1/8" tubing. *3 Only polyurethane tubing is applicable for 2.
Terminal q DC (+) w N.C e DC () r IN (1 to 5 V) e w q Power supply/Output connection cable (Accessory) Power supply/Output connector (8P) Pin no. 7 Green 8 Yellow 6 Red 5 Gray 4 White 3 Black 2 Blue 1 Brown i u y t r e w q Pin no.
Applicable model 84 84 03 FGD-CV002-04 06 03 FGD-CV003-04 06 03 FGD-CV004-04 06 03 FGD-CV001-04 06 32 32 FGDT/F FGDT/F FGDC/E FGDC/E Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4).
When the ambient temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Also, take measures to prevent ingress of water and foreign matter from the breathing port of the diaphragm. 5-5-10 1 3 Port Air Operated Valve Series VGA342 How to Order SA 04 VGA342 A VA Port size Passage A Normally closed (N.C.) B Normally open (N.O.) Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O.
VO307 5 D 1 Q CE-compliant CE-compliant Coil rated voltage Coil rated voltage CE-compliant Nil Q CE-compliant Nil Q 1 2 3 Note 1) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 1 2 3 Note 1) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only Note) Electrical