SMC Corporation of America
Elite Part Number Search
Search Results "CD75E40-50C-B"

port regulator) ARB310-00-B ARB210-00-B Can be made into manifold with series VV72.

Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Port size Weight Valve model Grommet C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT307 VT307V (Vacuum spec. type) VT307E (Continuous duty type) VT307Y (Energy-saving type) VT307W (Energy-saving, Vacuum spec. type) VT307 VT307V (Vacuum spec. type) VT307E

Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT325 VT325V (Vacuum spec. type) VT325 VT325V (Vacuum spec. type) 0.55 kg (For AC) 0.60 kg (For DC) Note) Values for a single valve unit.

) The IN air passes the check valve to pressure boosting chambers A and B.

Note 2) 400 V type is provided with an earth leakage breaker -B as standard.

Symbol (B) 2 (A) 4 1 (P) 3 (R) Flow Rate Characteristics C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 14/2(PA/B) 4/25/3(A/BEA/EB) Flow rate characteristics Valve model Port size Body ported 10-VQD1121(V)-L M-M5 10-VQD1121 -L M-M5 10-VQD1151(V)-L M-M5 10-VQD1151W-L M-M5 0.05 0.07 0.06 0.07 Base mounted (With sub-plate) 0.22 0.27 0.22 0.27 0.16 0.24 0.10 0.25 0.05 0.07 0.05 0.07 0.19 0.28 0.22 0.27

Endurance 10 G; X, Y, Z directions, 3 times each Impact resistance 350 g or less Weight 1) 90 phase difference input Multi-counter/Dimensions A phase I 24-M3 x 0.5 B phase J A B C D A COM COM COM B 12 VDC GND F.G.

Effective area (mm2) Weight (g) Dimensions (mm) 20 35 1 5 9.5 20 1 3.3 22.5 38 9 17 11 A B 13 6 8 Note) NPT thread for AN101 and AN110 is alsoavailable.

(Values at the initial period) Note 3) At rated voltage Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Weight Valve model Grommet C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT317 VT317V (Vacuum spec. type) VT317E (Continuous duty type) 0.29 kg 2.4 0.26 0.62 2.6 0.34 0.67 2.8 0.25 0.67 2.5 0.37 0.66

Replacement method Standard replacement period Refrigerating compressor 1 B 20,000 hours (6 years) Plate type heat exchanger 1 B 20,000 hours (6 years) Water regulating valve 1 B 20,000 hours (6 years) High pressure switch 1 B 20,000 hours (6 years) Low pressure switch 1 A 20,000 hours (6 years) Magnetic contactor 1 A 20,000 hours (6 years) Programmable controllers 1 A 20,000 hours (6 years

Circulating fluid return port When heating the circulating fluid, the high-pressure, high-temperature refrigerant gas is bypassed into the evaporator by expansion valve B to heat the circulating fluid. The combination of the precise control of expansion valve A for cooling and expansion valve B for heating allows for high temperature stability.

Optuon B ventilation air outlet Earth leakage breaker Handle Lid for circulating fluid fill port (There is a handle on the other side too.)

Cv b Cv b Cv b Cv Grommet VTA315 1.6 0.30 0.39 1.7 0.39 0.45 1.9 0.38 0.49 1.7 0.36 0.45 0.16 VOA315 1.4 0.12 0.33 1.2 0.18 0.29 1.5 0.16 0.35 1.2 0.13 0.28 Construction/Dimensions Precautions Breathing port of diaphragm Pilot port Rc 1/8 Be sure to read before handling.

For driving air operated valves for fluid control N.C N.O N.C N.C Air operated style fluid control valve Vacuum valve Vacuum pad A, B 1(P) A, B 1(P) A, B 1(P) A, B 3(P) 3(R) 3(R) 3(R) 1(R) Vacuum releasing air Atmospheric pressure or micro pressure The characteristic values shown in the catalog are representative values, not warranting the performance. 4-3-1 2 Series SY100 Precautions Be

Y 0 16 IN313-DN1-B, IN313-PR1, IN313-AB1/AB2 Three major protocols are available: DeviceNetTM (IN313-DN1-B), Profibus-DP (IN313-PR1), Allen Bradley RIO (IN313-AB1, & IN313-AB2) Controls up to 16 (32 in case of IN313-AB2), single solenoid valves. (A combination of single and double solenoid valves as long as the maximum number of solenoids does not exceed 16 (32 for IN313-AB2.)

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 12 V Body size Port size Rc Option Symbol P/A port R port B (Bracket) F (Foot) G (Pressure gauge) N (Silencer) 00 M5 00 M5 01 00 01 02 00 02 03 04 Symbol Mounting Without sub-plate M5 Without sub-plate M5 D B 1 8 Without sub-plate Base mounted 1 8 1 4

The proof pressure is double the operating pressure range. -69No.LV50***-OMQ0002-G Analogue output Flow/Analogue output Output A B C Voltage output 1 V 1.1 V 5 V C Current output 4 mA 4.4 mA 20 mA Rated flow[L/min] B Model Minimum Maximum A LFE1 0.5 20 Flow rate 0 Minimum rated flow Maximum rated flow LFE2 2.5 100 LFE3 5 200 Out of range -70No.LV50***-OMQ0002-G Dimensions Note) The electrical

The proof pressure is double the operating pressure range. -70No.LFE*-OMZ0011 Analogue output Flow/Analogue output Output A B C Voltage output 1 V 1.1 V 5 V C Current output 4 mA 4.4 mA 20 mA Rated flow [L/min] Model B Minimum Maximum A LFE1 0.5 20 LFE2 2.5 100 Flow rate 0 Minimum Maximum rated flow LFE3 5 200 rated flow Out of range -71No.LFE*-OMZ0011 Dimensions Note) The electrical entry

Approx. 1.00 mm Colours Brown, blue, black, white, grey Sheath Material Heat and oil resistant plastic Finished O.D. 3.5 mm -63No.LFE*-OMZ0013 Analogue output Flow/Analogue output Output A B C Voltage output 1 V 1.1 V 5 V C Current output 4 mA 4.4 mA 20 mA Rated flow [L/min] Model B Minimum Maximum A LFE1 0.5 20 LFE2 2.5 100 Flow rate 0 Minimum Maximum rated flow LFE3 5 200 rated flow Out