L2 + (3 x P) L2 + (3 x P) K axis (T axis) J axis Q1 = M L1 = L1 + (3 x P) L2 = The maximum dimension L1 is, as a rule, twice the thread size. (Example) For M3: L1 = 6 mm The maximum dimension L2 is, as a rule, twice the thread size. (Example) For M3: L2 = 6 mm However, for M5 with T shaft, the maximum dimension L2 is 1.5 times the thread size.
65 60 Inrush Frequency (Hz) 50 45 55 50 65 60 50 60 50 60 50 60 50 60 50 60 50 60 9 7 19 16 30 25 11 8 20 18 32 27 VX21 VX21 VX22 VX22 VX23 VX23 Note) The values are for an ambient temperature of 20C and at the rated voltage.
Table 8-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L]
Note1) Applicable model HRR012/018-A/W-10-T/MT HRR012/018/024/030-A/W-20-T HRR012/018/024/030-A/W-20-MT Rated flow50/60Hz Note23 L/min 7(0.36MPa)/10(0.42MPa) 10(0.42MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Maximum pumphead 50/60Hz m 50 50 50 Pump Output W 320 550 Circuit protector A 15 15A10A for standard Recommended earth leakage breaker capacity A 15 Cooling capacity Note 4 W The cooling
50 Band, Rail, Tie-rod Mounting Water Resistant 2-color Indication Type P. 10-20-54 Band, Rail, Tie-rod, Direct Mounting With Timer P. 10-20-60 Band, Rail, Tie-rod, Direct Mounting Magnetic Field Resistant 2-color Indication Type P. 10-20-64 Rail Mounting Wide Range Detection Type P. 10-20-65 Band Mounting Made to Order Specifications P. 10-20-66 ML2B C J G5-S CV MVGQ CC RB J D-X
Water Resistant 2-color Indication Type P. 6-16-50 Band, Rail, Tie-rod, Direct Mounting With Timer P. 6-16-55 Band, Rail, Tie-rod, Direct Mounting Magnetic Field Resistant 2-color Indication Type P. 6-16-58 Rail Mounting Wide Range Detection Type P. 6-16-59 Band Mounting Made to Order Specifications P. 6-16-60 NCA D-X 20Data Technical Data 1, 2 P. 6-16-63 6-16-1 2 SMC Auto Switch
However, the piston speed at this time should be adjusted to the minimum speed. 15 65 10 (n = 2, 4, 6 ) 65 + 50 (n 2) (n = 2, 3, 4, 5 ) 20 + 50 n 2 2 20 65 10 D-H7LF (n = 2, 4, 6 ) 15 + 50 n 2 2 D-B5 D-B6 15 75 10 (n = 2, 4, 6 ) Mounting 75 + 55 (n 2) (n = 2, 3, 4, 5 ) 20 + 50 n 2 2 Caution D-B59W 20 75 15 (n = 2, 4, 6 ) 1.
Type P. 9-15-23 Band, Rail, Tie-rod Mounting CNS CLS CLQ MLGP RLQ MLU P. 9-15-26 Solid State Switches ML1C DGeneral Purpose Type P. 9-15-27 Band, Rail, Tie-rod, Direct Mounting Normally Closed Type P. 9-15-39 Direct Mounting 2-color Indication Type P. 9-15-42 Band, Rail, Tie-rod Direct Mounting 2-color Indication Type with Diagnostic Output P. 9-15-50 Band, Rail, Tie-rod Mounting
Description Material AS800 AS900 y u i JIS B 2401 P-7 JIS B 2401 P-7 AQ NBR O-ring u O-ring O-ring Spring NBR NBR Stainless steel JIS B 2401 P-12 JIS B 2401 G-50 14115 JIS B 2401 P-16 JIS B 2401 G-65 14124 JIS B 2401 P-48 JIS B 2401 P-38 NBR O-ring ASV i AK ASS Dimensions: AS420/500/600 Dimensions: AS800/900 ASR ASF 2-Port size 2-Port size Dimensions Dimensions L1 L2 L4 Min.
60 1 2 100 VAC, Hz 200 VAC, Hz 50 60 50 60 3 4 5 6 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 7 240 VAC, Hz 50 60 Port size 50 60 Note 1) CE-compliant: Electrical entry is applicable only for the DIN terminal.
D-M9 D-A9 Ports Ports Compact Guide Cylinder Variations Series Bearing Bore size [mm] Cushion Piping Standard stroke [mm] 12 16 20 25 32 40 50 Basic type MGPK Slide bearing 12, 16: 10 to 150 20, 25: 20 to 200 32 to 50: 25 to 200 Ball bushing Rubber Top/Side ported Top ported (12 and 16 only) CONTENTS How to Order p. 3 Dimensions p. 8 Specifications p. 4 Model Selection p. 10 Weight
Max. load current or current range (mA) None 5 to 50 5 to 50 5 to 25 5 to 12.5 20 50 25 12.5 30 D-A53 PLC 24VDC 24VDC 100VAC 200VAC 4 to 8VDC 24VAC/DC or less 100VAC 200VAC Max. 24VDC D-A54 Relay, PLC None IC circuit D-A56 None D-A64 Relay, PLC D-A67 None None (2 color indication) IC circuit, PLC D-A59W 5 to 40 24VDC Relay, PLC 5 to 50 5 to 50 5 to 25 5 to 12.5 50 40 20 5 to 40 5
400 300 300 200 200 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 100 100 80 0.3 4 5 10 3 2 0.4 1 0.2 80 5 10 20 50 4 3 2 1 m3 max m3 max m2 max m1 max m2 max m1 max Load weight kg Load weight kg Horizontal impact: P = 0.5 MPa MY3B40 Horizontal impact: P = 0.5
(Piping port) G E G NN ( I ) D X NA R Mounting nut N W K N S + Stroke F F ZZ + Stroke H B E G Mounting nut NN NA F N CY3B15 (mm) Model CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 B 35 36 46 60 70 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 D 16.6 21.6 26.4 33.6 41.6 ZZ 103 132 137 156 182 E 3 2 2 2 3 N 11 18 18.5 20 26 F 10 13 13 16 16 MM M4 x 0.7 M4 x 0.7
page 12 for dimensions. 200, 220, 230, 240 VAC (50 Hz), 200 to 260V (60 Hz) 2 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase 380, 400, 415 VAC (50 Hz), 380 to 420V (60 Hz) 3 Compound 420, 440, 480 VAC (50 Hz), 420 to 520V (60 Hz) 4 Please refer to page 11 for dimensions.
CN1(P.18) 4.2 CN2CN3: LE-CA-CN3 CN2 4.3 CN4I/O 1 CN4 3m 16 - 2 (USB ) 120.3 120.3 mm mm 200 200 mm/s mm/s USB A-miniB type 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN4 4.4 CN5I/O PLC I/O CN5 PLC 6.4 I/O (P.27) 6.3 (P.24) 17 - 5.
(X867: Side porting type) 496 MGPW Series Compact Guide Cylinders, Series Variations Bore size (mm) Page Series Bearing type 6 63 80 100 20 25 32 40 50 10 12 16 Basic type/MGP P.432 Slide bearing With air cushion/MGP-A Ball bushing P.452 High precision ball bushing With end lock/MGP-H/R P.469 LOCK Slide bearing Wide type/MGPW Ball bushing P.498 High precision ball bushing Clean series/12/
186 q Installation Distance and Discharge Time p. 182 Alarm p. 186 w Static Neutralization Range p. 183 Mode Switch Setting p. 187 e Pressure Flow Rate Characteristics p. 184 Wiring p. 187 Dimensions p. 188 How to Order p. 185 Accessories (for Individual Parts) p. 185 Related Products p. 189 Specifications p. 186 AC Adapter Specifications p. 186 Specific Product Precautions p. 190 Parts
Base mounted Body ported 2(A) 1/4 3/8 P. 1558 8.9 (P)1 3(R) VPA700 For vacuum N.C.
Nil: Non-locking push type Manual override Body option B: Locking type B (Slotted) 0: Pilot valve individual exhaust type Manual override Manual override Rated voltage 1 2 3 4 5 6 7 9 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Other C: Locking type C (Manual) R port P/E port Manual override Light/Surge voltage suppressor