SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2L40TN-125N-D-A93"

DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) D 8 10.5 13.5 16.5 C 11 15 13 15.5 D 9 11.5 14.5 17.5 C 12 16 14 16.5 D 5 7.5 10.5 13.5 C 8 12 10 12.5 B 3.5 6 9 12 A 6.5 10.5 8.5 11 B 6.5 9 12 15 A 9.5 13.5 11.5 14 B 6 8.5 11.5 14.5 A 9 13 11 13.5 32

Materials: 12, 20 Steel 32 to 63 Rolled steel 30 d (mm) Bore (mm) D C H d B C D Part No.

Rail mounting Direct mounting D-F7BA D-F7lW D-F7lF D-J79W D-A7lH/A80H D-A73C/A80C D-F7l/J79 D-F7lV/J79C D-F9BA D-F9lW D-F9lWV D-F7lWV D-A9l D-A9lV D-F9l D-F9lV D-A79W D-A7l/A80 Bore size (mm) D 8 10.5 13.5 16.5 C 11 15 13 15.5 D 9 11.5 14.5 17.5 C 12 16 14 16.5 D 5 7.5 10.5 13.5 C 8 12 10 12.5 B 7 9.5 12.5 15.5 A 10 14 12 14.5 B 10.5 13 16 19 A 13.5 17.5 15.5 18 B 3.5 6 9 12 A 6.5 10.5 8.5

P.336 P.1785 (/) (/) 19 18-2. 12 16 20 25 32 40 50 63 80 100 1 2 1 2 1 15 2 15 1 15 2 15 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 10 15 5 10 5 10 10 5 10 D-A9 D-A9V D-M9V D-M9 10 10 10 10 D-M9W D-M9WV D-M9AVL 15 10 D-M9AL 15 10 5 D-Z7 D-Z80 D-Y59 D-Y7P D-Y69 D-Y7PV D-Y7W D-Y7WV 15 10 10 15 10 5 5 5 10 15 15 10 15 D-Y7BAL 10 20 75 18-3.

D-M9/D-A9 D-M9 D-M9W D-M9AVL D-M9V D-M9WV D-M9AL D-A9 D-A9V A B A B A B A B 50 23.5 9.0 23.5 11.0 23.5 7.0 19.5 10.5 (13.0) 63 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 80 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) ( )D-A96 -15 D-P3DW D-P3DW A B Hs Ht 50 14.5 6.5 41 35 63 16.5 10 47 44 80 30.5 17 55 54 D-P3DW BQ6-032S -16 18 - 7-3. 7-3-1.D-M9D-A9 (-) -17 5~6mm D-A9(V)

Proper Auto Switch Mounting Position (Detection at stroke end) MX A B MTS MY MY3A D-A9, D-A9V (mm) D-F9W, D-F9(W)V (mm) D-M9, D-M9V (mm) CY A B Operating range Bore size 16 25 40 63 A B Operating range Bore size 16 25 40 63 B Operating range Bore size 16 25 40 63 A 088.5 084.5 26.5 084.5 22.0 26.5 2 06.5 3.0 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080

Mounting bolt C D Mounting Bolt Size for NCQ8B056 to 250(Without Auto Switch) (Inch) Model C D Bolt size Model C D Bolt size NCQ8B056-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B075-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B106-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B150-012 025 037 050 062 075 087 100 125 150

Auto Switch Proper Mounting Position (mm) (mm) Auto Switch Mounting Height D-M9 D-M9W D-M9 D-M9W D-A9 Auto switch model Auto switch model D-A9 B A B A Bore size Bore size 20 25 32 40 Hs 30.5 59.5 34 55.5 20 25 32 40 Note) The above values are a guide in the stroke end detection of the mounting positions of the auto switch.

, Shore D 45D TUB-21 Tubing Related Equipment Related Equipment Tube Stand & Reel Series TB/TBR Compact size with a small footprint.

Part number of auto switch mounting bracket D-M9 Applicable auto switches D-M9W D-A9 Bore(mm) 12 to 63 Surface with auto switch mounting slot Auto switch mounting surfaces Mounting of auto switch Tightening torque Auto switch Mounting Screw (Nm) Auto switch model Tightening torque D-M9 D-M9W 0.05 to 0.15 D-A9 0.10 to 0.20 NoteAuto switch mounting brackets and auto switches are enclosed with

Variation: D (2-step Control, Single Acting/Bellows Seal, O-ring Seal), Flange Size: 40, Indicator, Actuator Port Direction: w/o Indicator, Actuator Port Direction on Flange Side, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: A93 (A93--Reed, DC Volt, AC Volt, LED, Horizontal), Lead Wire: L (3m), Number of Switches, Mounting Position: A (2 pcs, Valve Open/Closed)

D-M9B D-M9N, D-M9P D-A93 Load voltage Load current range Indicator light Application 24 VDC (10 to 28 VDC) 28 VDC or less 24 VDC, 100 VAC 2.5 to 40 mA 40 mA or less 5 to 40 mA, 5 to 20 mA 24 VDC relay, PLC IC circuit, Relay, PLC Relay, PLC Solid state auto switch PLC: Programmable Logic Controller Refer to page 920 for the applicable auto switch list. 905 Rotary Actuator 11-CRA1-Z Rotation

How to Order B 40 30 D CQ2X Without auto switch With auto switch CDQ2X A73 B 40 30 D Number of auto switches With auto switch (with built-in magnet) Auto switch type 2 pcs. 1 pc. "n" pcs. Nil S n Nil Without auto switch (with built-in magnet) Microspeed cylinder Select auto switch model number from the table below.

Band Mount: None, Rail Mount: None, Tie-rod Mount: None, Direct Mount: A93--Reed, 24VDC max, 100VAC max, LED, Horizontal

Sensor Type: Contacting, Output Format: N/A, Wiring Method: 2-Wire, Type: Main Body, Lead wire length(m): 0.5, Applicable load: Relay / PLC

Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 1000mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch

Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: L (3m Lead Wire), Number: 2 pcs.

Magnet: D (Built-in), Mounting: D (Double Clevis), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewied Connector: L (3m)

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: D (Lever Type w/Lock Mechanism, Adjustable Absorber Type), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or