(For details, refer to catalog on page 22.) 17 Series SYJ500 Construction c f a e b d c f a e b d N.C. N.O.
8 e Hexagon socket head cap screw CXTM Carbon steel Hard chromium electroplated Cylinder tube Aluminum alloy Hard anodized !
Determination of load's kinetic energy (E) bore size E > Es E Es Determination of bore size Review of larger bore size E = m E 2 a ( ) 2 = (Refer to page 8-16-8.) 1000 P Ps P > Ps Determination of pressure for intermediate stop (p) (Refer to page 8-16-8.)
Determination of load's kinetic energy (E) bore size E > Es E Es Determination of bore size Review of larger bore size E = m E 2 a ( ) 2 = (Refer to page 8-16-8.) 1000 P Ps P > Ps Determination of pressure for intermediate stop (p) (Refer to page 8-16-8.)
Supply port ISA3-C: Rc1/8 ISA3-F: G1/8 1 3 DC () 4 OUT1 Unit: mm Stations 1 2 3 4 5 6 1: Conforming to ISO1179-1 (49) 45 L1 38 76 114 152 190 228 (3.7) 18 L2 62.5 125 162.5 200 237.5 275 L3 73 135.5 173 210.5 248 285.5 Detection port ISA3-C: One-touch fitting ISA3-F: G1/8 1 Piping type C (4 One-touch fitting) C (6 One-touch fitting) F (G thread) H 13 13.6 19 17 3-Color Display Digital Gap
When the cylinder is pressurized from port B, range E can be adjusted by regulating angle adjustment screw C. When the cylinder is pressurized from port A, range F can be adjusted by regulating angle adjustment screw D.
drop [kPa] 8 8 AFJ40-04-80-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 80 m Large flow type Nominal filtration rating: 80 m 0 0 0 100 200 300 400 500 600 800 700 900 Flow rate [L/min(ANR)] 0 100 200 300 400 500 600 800 700 900 Flow rate [L/min (ANR)] 783 AFJ20 to AFJ40 Series Construction AFJ20 AFJ30, AFJ40 OUT IN OUT IN q q r r w w (y) e (y) t e t Component Parts No
CRB2 Counter-clockwise A port Positioning pin hole 5 Adjustment bolt A CRB1 (For counter-clockwise rotation end adjustment) 22 95 .5 e MSU ng Adjustment bolt B ra t (For clockwise rotation end adjustment) en CRJ tm se wi us ck dj a lo CRA1 -c nd B port er se Clockwise e nt wi on Cl ck u lo o oc C ad ti CRQ2 C ta 90 k ju ro wi st 1 se m r ge en ot With Adjustment Bolt at t r an io n an
wire length 0.6 m Nil Grommet type Lead wire length 3 m L NPN open collector, double output Analog, no output, 200 degree setting 17 Lead wire length 0.6 m C Connector type Lead wire length 3 m CL NPN open collector, single output Analog, with output, 3 turn setting 18 Without connector CN NPN open collector, single output Analog, with output, 200 degree setting 19 With connector/How to
Side mounting Panel mounting VM100/Bottom ported only 3 (R) (3 port) Pneumatic indicator 2 (A) 1 (P) Series VM100/200 CAT.ES12-8A a Series VM100/200 Actuator Variations * It is possible to change the actuator assembly and mount to basic type.
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com c B part e f d 2.
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Thread: None, Stroke: 250mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Thread: None, Stroke: 300mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Thread: None, Stroke: 125mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Thread: None, Stroke: 150mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating