SMC Corporation of America
Elite Part Number Search
Search Results "CDQSB16-35DCM-M9NWV"

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Pneumatic, Bore Size: 32mm, Stroke: 35mm, Body Option: Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -

Magnet: None, Mounting: Both Ends Tapped, Type: Pneumatic, Bore Size: 20mm, Stroke: 35mm, Body Option: Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Magnet: None, Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 20mm, Stroke: 35mm, Body Option: C (Rubber Bumper), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT LONG STK, ACTUATOR, CQS COMPACT CYLINDER, GE, 16MM CQS DBL-ACT AUTO-SW, .35137 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT LONG STK, ACTUATOR, CQS COMPACT CYLINDER, GE, 16MM CQS DBL-ACT AUTO-SW, .66138 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT LONG STK, ACTUATOR, CQS COMPACT CYLINDER, GE, 16MM CQS DBL-ACT AUTO-SW, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT LONG STK, ACTUATOR, CQS COMPACT CYLINDER, GE, 16MM CQS DBL-ACT AUTO-SW, .44092 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT, AUTO-SW, ACTUATOR, CQS COMPACT CYLINDER, HE, 20MM CQS DBL-ACT AUTO-SW, 0.76469 lb

Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 35mm, Body Option: Standard, Bumper/Rod End Thread: CM (Rubber Bumper, Rod End Male Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal

Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 35mm, Option: CM (Rubber Bumper,Rod End Male Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 20mm, Stroke: 35mm, Option: CM (Rubber Bumper,Rod End Male Thread), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)

Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 40mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: with Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental

Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: with Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental

Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 25mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: with Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental

Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 32mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: with Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental

Magnet: Built-in Magnet, Mounting: Double Clevis, Bore Size: 32mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: with Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental

Magnet: Built-in Magnet, Mounting: Double Clevis, Bore Size: 40mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: with Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental