Air filter (5 m or less) IR (Precision regulator) W D0.5 to 500 MQQL Anti-lateral load type (Built-in ball bushing) 0.005 to 0.7 When using a solenoid valve, use a metal seal type (Series VQ/VQZ/SQ, etc.).

Timing of Wireless Communication 20 / 40 / 100/ 200 / 500 / 1,000 / 2,000 / 5,000 msec 500 msec Activated only when protocol V.2.0 is used If wireless communication (including retries) does not succeed due to obstacles or for other reasons, it is judged to have failed after a set amount of time and disconnected. Afterwards, the Base and the Remote are reconnected.

TS0425G-500-X3 20 m roll Inch size: Suffix -X4 to the end of part number. Ex.) TISA01BU-20-X4 Made to Order Availability Length Model Part no.

mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal

500 0 0 0 10 20 30 40 0 10 20 30 40 Circullating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-11 Heating capacity (HRR050-A/W-20-) 9.5.2 HRR050-A/W-402000 2000 Ambient temp Ambient temp 1500 1500 Heating capacity[W] Heating capacity[W] 40 40 32 32 25 25 1000 1000 5 5 500 500 0 0 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature[] Circulating fluid temperature

CXSW6 1 0.5 0.4 0.3 0.2 0.1 0.05 Bore size (mm) 6 to 32 100 200 300 500 1000 0 50 CXSWM (Slide bearing) Cylinder speed Vp (mm/s) 0.1 CXSWL (Ball bushing bearing) 34 Dual-Double-Rod Cylinder Series CXSW Made to Order Auto Switches Precautions Compact Type CXSJ Standard Type CXS With Air Cushion CXS With End Lock CXS Construction CXSWM Slide bearing CXSWM6 CXSWL Ball bushing bearing CXSWL6

rotations Meter-in Type (Inlet Pressure: 0.5 MPa) ASQ530F ASQ430F ASQ630F 20 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) 400 Effective area mm2 Effective area mm2 Effective area mm2 6 12 1000 15 300 8 4 500 10 200 500 4 2 5 100 10 5 0 10 5 0 10 5 0 Number of needle rotations Number of needle rotations Number of needle rotations Pressure Characteristics (ASR) ASR430F,

Pressure 0.5 MPa Load rate: 50% Stroke 60 mm Series MB/CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series MB/CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ7140-02 Cylinder is in extending.

Buffer Specifications Model MXS6 MXS8 MXS12 MXS16 MXS20 MXS25 6 8 12 16 20 25 Bore size (mm) Horizontal mounting 2-20 in/s (50~500 mm/s) 2-12 in/s (50~300 mm/s) Piston speed Buffer stroke (mm) 5 10 At 0mm stroke At max. stroke 0.67 1.12 2.25 2.92 3.82 4.72 Buffer stroke load (lbf) 1.35 1.80 2.92 3.82 5.62 6.52 Note) Refer to P. 14 for cautions on buffer.

For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500

mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read

S = 38mm VCA21 200 300 400 500 600 700 VCA21 VCA31 VCA31 VCA41 VCA41 VCA41 Other 200 400 400 600 800 1000 1200 1. Material HNBR: Nitrile hydride rubber 500 700 500 1000 1500 800 1000 1200 1000 500 Flow rate Q l/min (ANR) Viewing the graph The sonic range pressure to generate a flow rate of 500l/min (ANR) is P = 0.64MPa for a 3 orifice, and P = 0.35MPa for a 4 orifice.

aqueous solution Karman vortex IP65 3-color display 0.1 L/min 5 40 10 100 1 L/min 50 250 2 L/min PVC piping type 1 L/min 10 100 Water, Ethylene glycol aqueous solution IP65 3-color display Karman vortex 2 L/min 30 250 PF2D 0.05 L/min 0.4 4 Deionized water (pure water), Liquids which do not corrode nor erode fluoropolymer IP65 1-color display Karman vortex 0.1 L/min 1.8 20 4 40 0.5 L/min

Annual cost reduction effect [Calculation conditions] Electric power cost: 1.55 yen/m3 [Work model] Working hours: 6000 h (250 days/year) Supply pressure: 1.0 MPa Set pressure: 0.2 MPa Comparison between IR3000-A and the current IR3000 Comparison between IR1000-A/IR2000-A and the current IR1000/IR2000 300 300 Annual cost of power consumed by compressor [1000 yen/year] 250 250 When 20 units

ISA2-G ISA2-H Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Standard pressure: 100 kPa Standard pressure: 100 kPa Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 0.4 0.6 Standard pressure Standard pressure 0.5 mm 0.25 mm Detection distance (mm) Detection distance (mm) 0.5 0.3 0.4 0.2 0.3 0.15 mm 0.15 mm 0.2 0.1 0.1 0.03 mm 0.01 mm 0 0 50 0 250 200 150 100 250

73 330 177 100 56 9.7 108 145 2 x M10 x 1.5 18 25 (1B) 32 (1 1/4B) 0 50 342 87 435 255 100 56 12.8 108 150 4 x M12 x 1.75 22 40 (1 1/2B) 50 (2B) 0 60 450 94 545 356 120 70 20.4 126 180 4 x M12 x 1.75 22 0 209 62 285 147 90 51 6.9 98 120 2 x M10 x 1.5 18 0 1 0 1 0 1 0 1 0 1 15 (1/2B) 4 x M10 x 1.5 4 x M10 x 1.5 4 x M12 x 1.75 4 x M12 x 1.75 4 x M16 x 2 4 x M16 x 2 20 (3/4B) 0 250 73 330

Solid state switches marked with a "p" symbol are produced upon receipt of order. 2 Series MLGP Cylinder Specifications Action Fluid Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed Cushion Lubrication Stroke length tolerance Double acting Air 1.5MPa (217 psi) 1.0MPa (145 psi) 0.15MPa (22 psi) -10C to 60C (14 to 140F) 50 to 500

mm (For the ZNC80) The values are for when the connection is as follows: Fitting min. hole diameter: 4.5, Tubing size: 6 x 4, Length: 500 mm *4 No freezing or condensation.

210 MXF16 690 500 360 MXF20 1370 1060 750 600 8-6-3 4 Series MXF Table Deflection (Reference values) Table Displacement due to Pitch Moment Load Table Displacement due to Yaw Moment Load Table Displacement due to Roll Moment Load Table roll deflection arrow A due to static roll moment applied at arrow F when Lr = (see table) and table is retracted.