Piping: Standard, Bore Size: 40mm, Port Thread: TN (NPT), Stroke: 800mm, Switch Rail: N (without Switch Rail), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: M (1m), Number: S (1 pc.)

Bore Size: 8mm, Opening & Closing Stroke: 1 (Middle Stroke), Body Option: Axial Direction Ported, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: M (1m), Number: S (1 pc.), Option: X83 (With an Adjustable Opening/Closed Finger Positioning), Stroke Adjustable Side: A (Both Sides), Stroke Adjustable Width: 2 (Long Adjuster)

Series NCM stainless steel cylinder offers space savings, high performance, and interchangeability with other stainless steel cylinders. A wear ring extends the seal life and a bronze rod bushing is standard on all bore sizes. The NCM is available in 4 mounting styles * as well as double rod and spring return or spring extend models. The NCM is auto-switch capable without any change in cylinder

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 20mm, Stroke: 25mm, Rod End Thread: Male Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: M (1m), Number: S (1 pc.), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)

Magnet: D (Built-in), Series: J2, Mounting: B (Basic), Bore Size: 16mm, Stroke: 30mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: M (1m), Number: S (1 pc.), Auto Switch Mounting Type: B (Band Mounting)

Magnet: D (Built-in), Series: J2, Mounting: B (Basic), Bore Size: 16mm, Stroke: 30mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: M (1m), Number: S (1 pc.), Auto Switch Mounting Type: A (Rail Mounting)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 15mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 15mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 15mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 4mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 15mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)