Mounting: -, Bore: -, Stroke: -, Cushion: -, Rod End Thread: -, Pivot Bracket: -, Rod End Bracket: -, Temperature Options: -
Mounting: -, Bore: -, Stroke: -, Cushion: -, Rod End Thread: -, Pivot Bracket: -, Rod End Bracket: -, Temperature Options: -
Bore Size: 15mm, Port Thread: M thread (ø10, ø15) Rc threads (ø25), Piping: Left Side Centralized Piping, Stroke: 200mm, Adjuster: Both Sides: 25mm Adjusting, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 25mm, Port Thread: M thread (ø10, ø15) Rc threads (ø25), Piping: Right Side Concentated Piping, Stroke: 200mm, Adjuster: Both Sides: 25mm Adjusting, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 10mm, Port Thread: M thread (ø10, ø15) Rc threads (ø25), Piping: Left Side Centralized Piping, Stroke: 200mm, Adjuster: Both Sides: 25mm Adjusting, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: None, Model: G (Steel, 14MPa), Mounting: LA (Transaxial Foot), Bore Size: 63mm, Rod Dimension: B (Series B Rod Size), Stroke: 200mm, Rod End Nut: A (w/Rod End Nut)
Magnet: D (With Magnet), Mounting: CB (Double Clevis), Bore Size: 63mm, Port Thread Type: TN (NPT), Stroke: 200mm, Rod End Nut: A (With Rod End Nut)
CHQ CHK CHN Mounting correctly Mounting incorrectly CHM CHM CHS
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ None N (Example) H7CN 3 m L (Example) M9NWL Since there are other applicable auto switches than listed above, refer to page 14 for details. For details about auto switches with pre-wired connector, refer to the WEB catalog or Best Pneumatics No. 3.
LAT LEJS40 LEJS63 Applicable auto switches D-M9N(V)-900, D-M9P(V)-900, D-M9B(V)-900 D-M9NW(V)-900, D-M9PW(V)-900, D-M9BW(V)-900 LZ *4 Please consult with SMC for non-standard strokes as they are produced as special orders. LC3F2 * Specifications and dimensions for the 25A-series are the same as standard products.
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
(Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ (Example) H7CN Since there are other applicable auto switches than listed, refer to page 1040 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785. D-A9/M9/M9W auto switches are shipped together (not assembled).
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked are produced upon receipt of order. Other than the applicable auto switches listed in How to Order, the other auto switches can be mounted. For detailed specifications, refer to page 1479.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ DSince there are other applicable auto switches than listed, refer to page 697 for details. For details about auto switches with pre-wired connector, refer to pages 1014 and 1015. D-A9/M9/M9W/M9A(V) auto switches are shipped together (not assembled).
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked with are produced upon receipt of order. The D-G5/K5/B5/B6 types cannot be mounted on the bore size 40. D-X Since there are other applicable auto switches than listed above, refer to page 376 for details.
(Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ (Example) H7CN Since there are other applicable auto switches than listed, refer to page 1040 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785. D-A9/M9/M9W auto switches are shipped together (not assembled).
DLead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to pages 1648 and 1649. Normally closed (NC = b contact) solid state auto switches (D-F9G/F9H types) are also available. Refer to page 1593 for details.