, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 25 32 40 2000 2000 2000 *When the required stroke is longer than the standard stroke , refer to the specifications for Made to Order q (p.5.4-79) longer stroke styles.

actuation 600 500 400 300 200 100 0 SX3140-01 900 800 700 600 500 400 300 200 100 0 SX5140-02 900 800 700 600 500 400 300 200 100 0 SX7140-03 It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.

Speed [mm/s] 1 1 100 0.49 2 2 200 0.74 3 3 300 0.98 4 4 400 1.23 5 5 500 1.47 6 6 600 1.96 7 7 700 2.45 8 8 800 2.94 9 9 900 3.92 10 10 1000 4.90 Note) The factory default setting for the switch is No.1 (100 mm/s).

,500 900 5.600,000 1?.8 61.30 33.r0 ADA775 .98 30 2.J00 s00 6.000.000t3.1 65.30 35.t0 ADATEO l , t 0 r l o n o I .98 32 2,500 i00 6,300,000 14.3 69.35 37.t0 *Note: The maximum load capacity for mounting option K is 650 lbs' A I dimensions in inches. I Rate Controls @grl9.

, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.

Built-in-magnet Accessories Mounting Rod boot Variations Standard stroke (mm) JIS Symbol Standard Rod end nut Option Knuckle joint pin Clevis pin Single knuckle joint Double knuckle joint Trunnion pivot bracket Double clevis pivot bracket Basic Axial foot Front flange Rear flange Single clevis Double clevis Center trunnion 900 1000 Page Bore 50 100 150 200 300 400 500 25 75 125 175 250 350

Power Factor Table Bore Diameter: 34 1 118 112 2 214 212 3 314 4 6 Power Factor: .4 .8 1.0 1.8 3.1 4.0 4.9 7.1 8.3 12.6 28.3 Example: Estimated force needed is 900 lbs. Air pressure to be used is 80 PSI: 80 PSI x Power Factor = 900 lbs. Power Factor = 900 lbs / 80 PSI = 11.25 The power factor just above 11.25 is 12.6.

Power Factor Table Bore Diameter: 34 1 118 112 2 214 212 3 314 4 6 Power Factor: .4 .8 1.0 1.8 3.1 4.0 4.9 7.1 8.3 12.6 28.3 Example: Estimated force needed is 900 lbs. Air pressure to be used is 80 PSI: 80 PSI x Power Factor = 900 lbs. Power Factor = 900 lbs / 80 PSI = 11.25 The power factor just above 11.25 is 12.6.

Bore size System Average speed [mm/s] MB, CA2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 500 mm 40 50 63 80 100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal A 1000 900 800 700 600 500 400 300 200 100 0 B 1000 900 800 700 600 500 400 300 200 100 0 C Bore size System Average speed [mm/s] CS1/CS2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 300 mm 125 140 160

1 Large Flow Air Filter Series AF800/900 Standard Specifications F.R.L.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 900 kPa 900 Output deviation factor (% F .S.) 800 kPa IR 800 0.5 700 kPa Set pressure (kPa) 700 600 kPa VEX 600 Out 500 kPa 500 0 400 kPa AMR 400 Return 300 kPa 300 0.5 ITV 200 kPa 200 100 kPa 100 50 kPa IC 0.4 0.6 0.8 1.0 1 0 1 2 3 4 5 6 0 7 1.2 Flow

Piping: Standard, Bore Size: 32mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 600mm, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

Piping: Standard, Bore Size: 32mm, Port Thread: M Thread: 6, 10, 15; Rc: 20~63, Stroke: 200mm, Switch Rail: without Switch Rail, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Piping: Standard, Bore Size: 32mm, Port Thread: M Thread: 6, 10, 15; Rc: 20~63, Stroke: 700mm, Switch Rail: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Piping: Standard, Bore Size: 32mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 500mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: M (1m)

Piping: Standard, Bore Size: 32mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 350mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)