SMC Corporation of America
Elite Part Number Search
Search Results "FH340-03-100-P010"

Piping adapter Spacer with Bracket Mounting Position Dual residual pressure release valve (-X538) Dual residual pressure release valve with soft start-up function (-X555) (Max. 10) 201.8 82.9 (14) (14) 201.8 (Max. 10) 82.9 IN OUT IN OUT d c b a d a b c Model a b c d Note Model a b c d Note VP544-5DZ1-03-X538 33.9 57.2 95.7 220.7 AW30-03G-A Y300T-A E300-03-A VP544-5DZ1-03-X555 33.9 57.2 129.2

T NPTF Coil rated Electrical entry 3 8 G F 1 100 VAC, 50/60 Hz Grommet Nil T Conduit terminal Standard 4 1 2 Option 2 200 VAC, 50/60 Hz Port size Manual override P None Nil Option WTB Dripproof conduit terminal 3 110 VAC, 50/60 Hz 1 4 Rc 3 8 Rc 1 2 Rc 3 4 Rc 02 03 04 06 TZ Conduit terminal w/ surge voltage suppressor 4 220 VAC, 50/60 Hz How to Calculate the Flow Rate 5 24 VDC 9 Other TL

For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500

Metric size Type (recommended flow rate) Symbol Tubing size Applicable model 04 ZFC100 ZFC100 ZFC200 ZFC200 4 Flow rate l/min (ANR) (SCFM) Symbol Tubing size 100 200 101 201 Max. 20 (0.70) Max. 50 (1.75) Max. 20 (0.70) Max. 50 (1.75) Metric size (release button: light gray) 06 6 08 8 Inch size (release button: orange) Inch size Symbol 03 Applicable model ZFC101 ZFC101 ZFC201 ZFC201 Tubing

150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read the graph The sonic range pressure to generate a flow rate of 500 l/min (ANR) is P1 0.14 MPa for a 6 orifice (VX2 4), and P1 0.3 MPa for a 4.5 orifice (VX23). 3 2 For Saturated Steam [663] (179

Metric size Type (recommended flow rate) Symbol Tubing size Applicable model 04 ZFC100 ZFC100 ZFC200 ZFC200 4 Flow rate l/min (ANR) (SCFM) Symbol Tubing size 100 200 101 201 Max. 20 (0.70) Max. 50 (1.75) Max. 20 (0.70) Max. 50 (1.75) Metric size (release button: light gray) 06 6 08 8 Inch size (release button: orange) Inch size Symbol 03 Applicable model ZFC101 ZFC101 ZFC201 ZFC201 Tubing

Metric size Type (Recommended flow rate) Symbol Tubing size Applicable model 04 ZFC100 ZFC100 ZFC200 ZFC200 4 Flow rate (/min (ANR)) Symbol Tubing size 100 200 101 201 Max. 20 Max. 50 Max. 20 Max. 50 Metric size (Release bushing: Light gray) 06 6 08 8 Inch size (Release bushing: Light gray) JIS Symbol Inch size Symbol 03 Tubing size 5/32" Applicable model ZFC101 ZFC101 ZFC201 ZFC201 Element

Symbol Note 1) Drain guide is NPT1/4 (applicable to AW30 to 40) Note 2) Drain guide is G1/4 (applicable to AW30 to 40). 20 30 40 30 40 01 02 03 04 06 1/8 1/4 3/8 1/2 3/4 02 03 04 06 1/4 3/8 1/2 3/4 Option Note 3) Option Note 3) Description With bracket Applicable model AW30, 40 AW30, 40 AW30, 40 Symbol Nil B G Note 4) H Description With bracket Applicable model AW20 to 40 AW20 to 40 AW20

Note) Metric size 23 04 06 08 10 12 Inch size 3.2 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 Made to Order (For details, refer to page 622.)

6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AM AFF2B 1 8 1 4 3 8 166 187 187 218 218 241 241 277 334 24 27 27 32 32 37 37 39 55 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 150/50 (5) Grommet, DlN terminal VT Standard 100, 200 VAC, 50/60 Hz; 24 VDC 220, 110, 48, and 24 VAC (50/60 Hz) 100, 48, and 12 VDC Coil rated voltage VP Option 15 to 10% of rated voltage Allowable voltage fluctuation Coil insulation type VG Class B or

min Size (port size) Size (port size) For Air Series variations Flow rate Remote type Output specifications Port size (Rc, NPT, G) Integrated measurement Analog output Accumulated display type Switch output pulse output 1/8 1/4 3/8 1/2 11/2 1 2 Display unit Sensor unit range l/min PFA510 550 511 521 551 PFA710 750 711 721 751 703H 706H 712H P P P 1 to 10 PFA30m P P P 5 to 50 P P P 10 to 100

Japanese N ...North American No Of Needle Revolutions 10 Turns / 8 Turns (AS1001F) Applicable Tube Material Nylon, Soft Nylon, Polyurethane A P P L I C A B L E T U B E OD B O D Y S I Z E mm 23 32 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 100 ...M5 (04, 06) 200 ...1/8 (04, 06) 205 ...1/4 (06, 08) 300 ...3/8 (06, 08, 10, 12) 400 ...1/2 (10, 12) W I

(mm) 4 6 8 10 12 (1) AS221FE-01 AS231FE-01 20, 25, 32 R 1/8 AS221FE-02 AS231FE-02 20, 25, 32, 40 R 1/4 AS321FE-03 AS331FE-03 40, 50, 63 R 3/8 AS421FE-04 AS431FE-04 63, 80, 100 R 1/2 Note 1) Elbow type only Note 2) Distinction between meter-out/meter-in types by appearance Those are distinguished by the lock nut.

3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.

AS331F-03 R 3/8 63, 80, 100 AS421F-04 AS431F-04 R 1/2 Note 1) Elbow type only Note 2) Meter-out and meter-in types can be visually differentiated by the lock nut.

With One-touch fitting Needle Valve/Flow Characteristics ASP330F ASP430F 400 200 3 6 Flow rate (l/min (ANR)) Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) 300 06 07,08,09 2 4 200 100 1 2 100 0 0 0 5 10 0 5 10 Number of needle rotations Number of needle rotations ASP530F

(Applicable to all models) (Ex.)A731 D-A731 Ac ces s sorie sl Part s Li st 056 (e^6) 075 (3/4) 106 0n/16) 150 (1-1/2') 2OO (2') 25O (2-1t2',) 300 (3') 400 (4"' Jam Nd JM.O1 JM-02 JM-03 JM.O4 JM.O5 JM-05 JM-08 JM-10 Single Rod Clevis RCS-015 BCS-02 RCS-03 RCS-04 HCS-o5 RCS-05 RCS-08 RCS-10 Double Rod Clevis RDS-o15 RDS-02 RDS-03 RDS-04 RDS-05 RDS{5 RDS.08 RDS-10 w/ dn(l). rcteinino rin6{21

For Water Digital Flow Switch Series PFW How to order PFW7 20 03 27 Integrated display type Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Unit specification Thread type Nil M With unit switching function Fixed SI unit Note) Rc NPT G Nil N F Wiring specification Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l 3m lead wire with connector Without lead wire