AS1200-M3 AS1400-M3 AS120-M5 AS220-01AS220-02 AS320-03 AS420-04 10-32UNF Port size M3 x 0.5 2.5, 4, 6 1.05 MPa 0.7 MPa 0.1 MPa M5 x 0.8 1/8 1/4 20, 25, 32, 40 3/8 1/2 6, 10, 15, 20, 25 80, 100 32, 40, 50, 63 Applicable cylinder bore size (mm) 1.5 MPa 1 MPa 0.1 MPa Proof pressure Max. operating pressure Body swivels 360 Swivel type allows free setting of piping.
Applicable cylinder bore size (mm) AS121-M5 Model Port size 4 6 8 10 12 M5 x 0.8 6, 10, 16, 20 Construction 1 8 AS221-01 R 20, 25, 32 1 4 AS221-02 R 20, 25, 32, 40 3 8 AS321-03 R 40, 50, 63 1 2 AS421-04 R 63, 80, 100 Note) marking is electroless nickel plated, provided as standard.
06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR3l00-02 to 03 AMR4l00-02 to 04 AMR5l00-04 to 06 AMR6l00-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.)
Flow Rate and Effective Area VR1211F Model 6 4 3.2 Metric size Applicable tubing O.D. 1/4" 5/32" 1/8" Inch size Flow rate l/min (ANR) 170 150 120 100 INOUT 2.6 2.3 1.8 1.5 Effective area mm Note 1) Flow rate values are at a pressure of 0.5MPa and temperature of 20C.
Solvent resistance (benzene, toluene) Oil resistance (gasoline) Oil resistance (benzol) Item Material Durometer HS( 5) Operating temperature range C Alkali resistance Acid resistance Weather resistance Ozone resistance Abrasion resistance Water resistance X 0 to 120 50 X X NBR X X X 30 to 200 40 X X Silicon rubber X X X X 0 to 60 60 X Urethane rubber X 0 to 250 60 Fluoro rubber X X 0 to 100
) 0.6mm ( for PVQ13) 0.8mm ( for PVQ13) 1.6mm ( for PVQ31, 33) 2.3mm ( for PVQ31, 33) 4.0mm ( for PVQ31, 33) M G Flow rate characteristics PVQ13-5-04 (24VDC type) at 0.45MPa PVQ3-5G-23 (24VDC type) at 0.35MPa 140 8 7 120 6 100 Flow rate (Lit/min) Flow rate (Lit/min) 5 80 4 60 3 40 2 20 1 0 0 30 40 50 60 70 80 75 85 95 105 115 125 135 145 155 165 65 Current (mA) Current (mA) Dimensions
How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 3.2 23 04 06 01 03 07 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2.
Terminal screw (3 positions) Tightening torque 0.2 to 0.25 Nm Housing (Position for light mounting) Terminal block Slot area Grommet type Red (+) Black () Connector part no.: VK300-82-1 Part no. of connector with indicator light Surge voltage suppressor Rated voltage Voltage symbol 100 VAC 100V Part no.
Terminal screw (3 positions) Tightening torque 0.2 to 0.25 Nm Housing (Position for light mounting) Terminal block Slot area Surge voltage suppressor Red (+) Black () Connector part no.: VK300-82-1 Part no. of connector with indicator light Rated voltage Voltage symbol 100 VAC 100V Part no.
+N.C. 8() 04 2xRc1/2 K2 N.C. *1 F06 G3/4 B1 N.0.+N.C. *1 F04 2xG1/2 B2 N.O.
T 100 2 () 100 IDF Series 4-1 4 1 IDX-OM-W026 4 4-2-3 0 OFF 50 1015 ( 1 INOUT IDF Series 4-2 4 2 IDX-OM-W026 4 30 30 (2) IDF Series 4-2 4 3 IDX-OM-W026 4 AD48-A 1 C42FP-260S 1 111692 1 1 20193 20192 SERIAL No.XP AD48 SMC WEB IDF Series 4-2 4 4 IDX-OM-W026 5 5 5-1 3 ON OFF () 3 2 R T 5-2 600mm 1 5-2 5-2 10% 5-2 () ( 60cm 1 ) 10% 3 IDF Series 5-1 5 1
O-ring Port plug Body Ported Base Mounted Blanking plug (For One-touch fittings) KJP-02 A L Dimensions [mm] Applicable fitting size d Model A L D Weight [g] 2 KJP-02 8.2 17 3 0.1 3.2 KQ2P-23 16 31.5 5 1 4 KQ2P-04 16 32 6 1 23 KQ2P-04 D Silencer (For manifold EXH port) Body Ported Base Mounted Silencer is installed in the EXH port.
Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 Flow
FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER, OTHERS, FHG HYDRAULIC FILTER, FX, FHG 1/2INCH (MISC./OTHER), 4.18878 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER, HYDRAULIC, OTHERS, FHG HYDRAULIC FILTER, FX, FHG 1/2INCH (MISC./OTHER), 4.47003 lb
Max Operating Pressure: 21 MPa, Construction: Element Upward Removal, Threaded, Port Size: 3/8 Threaded, Pressure Indicator: Differential Pressure Indicator, Relief Valve: Relief Valve, Fluid: Water-glycol, Emulsion, Element: Micromesh, Filtration: 10μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration
Max Operating Pressure: 7 MPa, Construction: Element Upward Removal, Threaded, Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: Differential Pressure Indication Switch, Relief Valve: Relief Valve, Fluid: Petroleum, Element: Micromesh, Filtration: 10μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration
Max Operating Pressure: 7 MPa, Construction: Element Upward Removal, Threaded, Port Size: 12 [1 1/2 Threaded, 40 (1 1/2) Flange SSA], Pressure Indicator: Differential Pressure Indication Switch, Relief Valve: None, Fluid: Petroleum, Element: Micromesh, Filtration: 10μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: None, Relief Valve: None, Fluid: Petroleum, Element: Micromesh, Filtration: 10μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration