On the other hand, in ordinary counters, no. 1 is set to 9.98 and no. 2 is set to 10.06, and if no. 1 is ON and no. 2 is OFF, an acceptance decision is made. 2 points of output are used in order to check whether or not the product is within dimension tolerances. In this example, one preset of the CEU5 performs the same function as two presets of an ordinary counter.
On the other hand, in ordinary counters, no. 1 is set to 9.98 and no. 2 is set to 10.06, and if no. 1 is ON and no. 2 is OFF, an acceptance decision is made. 2 points of output are used in order to check whether or not the product is within dimension tolerances. In this example, one preset of the CEU5 performs the same function as two presets of an ordinary counter.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 46 3/8" 24 52 28 23 21 44 1/2" M 55 1/2" H 29 62.5 39 32 26 53.5 3/4" 72 3/4" 25 1 39.5 81 49 46 36 71 1" Class 6 Inch sizes (A) shows the reference dimension after connection.
For mounting D-A9(V), M9(V), M9W(V), M9A(V) with 32 to 50 to a surface other than the port surface, order an auto switch mounting bracket separately.
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: AK (w/Caster Adjuster-foot and Fluid Fill Port)
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Caster Adjuster-foot and w/Fluid Fill Port, Manual Fill
Cooling Capacity: 25 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 28 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 20.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 15.7 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 10.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: w/Caster Adjuster-foot and Fluid Fill Port
Cooling Capacity: 15.7kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 20.5kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 25kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 28 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 10.5kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 250 (25 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AK (A + K)
Cooling Capacity: 300 (28 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AK (A + K)
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AK (A + K)