SMC Corporation of America
Elite Part Number Search
Search Results "HRS200-A-46-AS"

Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if a surge is applied repeatedly. When directly driving a load which generates surge, such as a relay or solenoid valve, use a type of switch with a built-in surge absorbing element. 8.

As a result, the fingers could become loosened and adversely affect the service life of the unit.

valve VFS41 (single) and a release valve spacer can be used as an air release valve.

Select an air filter with a filtration size of 5 m or smaller. 2. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause a malfunction of pneumatic equipment such as valves.

Use this as a standard when mounting, etc. Auto switches have hysteresis similar to micro switches. Use the table below as a guide when adjusting auto switch positions, etc.

U U Side The side connected to the solenoid valve when the product is connected to a manifold. 9 EX## OMS1015-A Assembly Composing the unit as a manifold : If the unit was purchased as a manifold, the work described in this section is not necessary. (1) Connect the unit to the end plate. The Digital unit, Analog unit can be connected in any order.

Note 2) The dimensions are the same as the standard type. B 1.8 1.6 Groove position of auto switch A 10.4 12.8 Model MHK2-12 MHK2-16 A B Dimensions A and B of other models are same as standard switch grooves. Standard switch grooves 12-6-17

Note 2) The dimensions are the same as the standard type. B 1.8 1.6 Groove position of auto switch A 10.4 12.8 Model MHK2-12 MHK2-16 A B Dimensions A and B of other models are same as standard switch grooves. Standard switch grooves 12-6-17

Use this as a guideline purpose only for model selection because the value varies depending on the material and/or size of a subject.

D-C7m/C80 D-C73C/C80C D-H7m/H7mW D-H7BA/H7NF Band mounting BJ2-010 (A set of band and screw) BJ2-016 (A set of band and screw) BQ2-012(S) (A set of a and b) BQ2-012(S) (A set of a and b) Set screw (Accessory) D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA Note 5) D-M9mAV Note 5) D-A9m D-A9mV Note 4) Rail mounting BQ2-012 BQ2-012S a Auto switch mounting screw b Auto switch mounting bracket Nut (Cylinder

items is handled as a special order product.

When mounting with bracket mounting nuts, tighten them using the tightening torques in the table below as a guide.

The proper tightening torque for pipe fittings is as shown in the table. As a rule, they should be tightened 2 to 3 turns with a tool after first tightening by hand. Be careful not to cause damage by over-tightening. Caution 1. The product cannot be used as a stop valve, of which zero leakage is required. The specifications of the product allow a certain degree of leakage. 2.

Through the availability of a wide range of series in terms of converter capacity and valve unit flow rate control capability, speed as high as 180 mm/s (throttle valve) can be achieved with a 80 cylinder.

Through the availability of a wide range of series in terms of converter capacity and valve unit flow rate control capability, speed as high as 200 mm/s (throttle valve) can be achieved with a 80 cylinder.

Note 2) The dimensions (A + stroke) and (B + stroke) for 10 mm stroke will be the same as those for 15 mm stroke.

Use caution, as there is a danger of being burned if a valve is touched directly. 2. Valves may reach high temperatures when continuously energized. Use caution, as there is a danger of being burned if a valve is touched directly. SOL. AC AC SOL. Without light AC SOL.

When a pressure-center (PAB) type 3-position solenoid valve is used, the table as well as the solenoid valve return to the center position when the power is cut due to blackouts, etc. If the return position must be at a particular rotation end either counterclockwise or clockwise when a blackout occurs, use two 3-port solenoid valves as shown below.

In this case, this product should not be used as a stopper.