Note 2) The flange can be mounted on the rotary actuator at 60-degree intervals.
Order Made Note) When an auto switch is installed at an intermediate position of a type with auto switch, keep the maximum piston speed at 300 mm/s or below to ensure operation of relays or other devices.
At least 3.5 characters of silent interval are necessary at the beginning and the end of the communication frame. b) Device Address This is a number to identify this product. 1 is the default setting.
At least 3.5 characters of silent interval are necessary at the beginning and the end of the communication frame. b) Slave Address This is a number to identify this product. 1" is the default setting.
Each screw shall be tightened at a torque of approx. 1.0 to 1.2Nm. Follow the procedure below (in order of part number) for assembling the angle adjustment unit. Note 1. Each screw shall be tightened at a torque of approx. Size 15 :1.0 to 1.2 Nm Size 20 :2.5 to 3.4 Nm Size 30 :4.0 to 6.0 Nm 6. Cap Cap 6. Cap 4. Hexagon socket 5.
Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.
How to Assemble and Replace Silencer Assembly (ZL6) The silencer assembly of the ZL6 series is not attached at the time of delivery. Please attach it before use. As shown in Fig. 1, align the hooks of the silencer assembly with the grooves on the body, and push in the direction of the arrow until it clicks.
However, when exceeding a 2000 mm stroke, specify -XB11 at the end of the model number.
(When the value at every 0.01deg.C is input, it is rounded off.)
When mounted with one side attached and one side unattached (basic type and flange type) and operating at high speed, bending moment acts on the cylinder due to oscillation at the stroke end, which may cause cylinder damage.
40 AFF,AM,AMD 80D 1 1/2 404 392 394.5 38 170 160 80 23 40 AFF,AM,AMD 90D 1 1/2 2 470 458 460.5 38 170 160 80 23 40 Model Bracket related dimensions H I J K L M N O P AFF,AM,AMD 70D 124 82 48.4 90 18 9 16 10 2.6 AFF,AM,AMD 80D 148 93.5 58.5 110 22 11 20 12 3.2 AFF,AM,AMD 90D 148 93.5 58.5 110 22 11 20 12 3.2 -22- Doc. no.
Supply Pressure Set the supply pressure at 0.25 to 0.5 MPa. If setting at less than 0.25 MPa, malfunction of the release brake may occur. If line pressure is used directly as supply pressure, any fluctuation in pressure will appear in the form of changes in cylinder characteristics.
Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 42 52 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 56 65 Two mounting screws (for mounting
Thus, in spite of using pneumatic equipment, it performs similarly to a hydraulic unit, operating at a constant speed during starting or in the presence of load fluctuations, and at the same time solving the problems of sticking and slipping associated with low speed operations.
After mounting or repair, connect the power supply to the product and perform appropriate functional inspections to check it is mounted properly. (8) At the overhang mounted impeller fixation There is a possibility that the power at the bending moment damages the electric actuator when moving it at high speed.
11 23 33 23 3 6 [Auto switch] 2-M3 x 0.5 (Bore size) 8.6 5.4 + Stroke 7.5 10 15 17 4 Series MGJ Auto Switches/Proper Mounting Position for Stroke End Detection B A A B (mm) Bore size Operating range 6 10 1.6 1.3 0.9 1.7 3 4 Auto Switch Mounting Watchmakers screw driver Auto switch mounting screw Use a watchmakers screw driver with a handle about 5 to 6 mm in diameter when tightening the
Moreover, position the wrench at the lower part of the hexagonal flats as close to the threads as possible. When a wrench of the proper size for the hexagonal flats is not used, it will cause the hexagonal flats to wear down. 3.
Refer to the manifold dimensions drawings for the L dimension. 25 35 VQZ 5.5 To order a manifold with DIN rail already attached, insert "D" at the end of the manifold part number. The DIN rail is approximately 30mm longer than the length of manifold. 12.5 VZ L dimensions L=12.5n+10.5 35.5 1 23 No.
10 mA (2 V or less at 40 mA) Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating range .
Action in the case of error If any error such as an abnormal sound, smoke, or bad odor occurs, cut off the power at once, and stop supplying and conveying fluid. Please contact SMC or a sales distributor to repair the thermo-con. 3. Regular inspection Check the following items at least once a month.