PG PH 1 2 U D B Tie-rod base manifold: SS5V1-10 D (S, R, RS) Stations (-D) When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
With control unit Centralized wiring/Supply port left Individual wiring/Supply port right Centralized wiring air catch sensor ISA2-HE41P Terminal box Individual wiring air catch sensor 2 port solenoid valve 2 port solenoid valve ISA2-GE41 Regulator 3 0 3 0 3 0 3 0 3 0 3 0 Supply port Supply port P P P P P P T T T T T T U U U U U U E E E E E E L L L L L L S S S L L L S S S L L L 6 9 6 9 6
P Q R 6 6 8 24.3 26.2 16.8 18.7 S 12.8 15.2 8 Applicable tubing O.D.
Stations J kit (Flat ribbon cable) G kit (Flat ribbon cable with terminal block) P kit (Flat ribbon cable) F kit (D-sub connector) Cylinder port Kit U S A U S P 26P 20P J U S U S F 15P U S P 16P U S B P 20P U S C P A 10P F 25P G Type Negative common specifications Max. points 24 14 24 18 14 8 16 16 Electrical entry Cable length M kit T kit (Terminal block box) S kit 0 1 2 With cable (0.6
Stations J kit (Flat ribbon cable) G kit (Flat ribbon cable with terminal block) P kit (Flat ribbon cable) F kit (D-sub connector) Cylinder port Kit U S A U S P 26P 20P J U S U S F 15P U S P 16P U S B P 20P U S C P A 10P F 25P G Type Negative common specifications Max. points 24 14 24 18 14 8 16 16 Electrical entry Cable length M kit T kit (Terminal block box) S kit 0 1 2 With cable (0.6
Locking type/Tool required SUP/EXH block plate Push type/Tool required SYJ Restrictor spacer Locking type/Manual External pilot 50/60 Hz 50/60 Hz Manifold SZ Grommet Plug-in VF VP4 VQ 1/2 VQ 4/5 VQ 4/5 VQC 1/2 VQC 4/5 VQZ P.481 P.482 P.476 P.476 P.477 P.477 P.477 P.477 P.478 P.478 P.479 P.480 (Except S kit) (Except S kit) (Except S kit) (Except S kit) SQ VFS VFR VQ7 P.527 P.522 P.522 P.523
VQC 4/5 S kit (Serial transmission [Fieldbus system]) EX600 P.562 VQZ VQC1000/2000 SQ S kit (Serial transmission) EX250 P.566 VFS VQC1000/2000 VFR S kit (Serial transmission) EX260 P.567 VQ7 VQC1000/2000 S kit (Serial transmission) EX126 P.570 VQC1000/2000 F kit (D-sub connector) P.572 VQC1000/2000 P kit (Flat ribbon cable) P.574 VQC1000/2000 T kit (Terminal block box) P.576 VQC1000/2000
Nil : : P R 20 20 stations A A S + + + + P, R port thread type R port A port size R P A port M5 x 0.8, C4 P port 1/8 Nil Rc M5 M5 x 0.8 P port F G A 1/8 1/8 C4 One-touch fitting for 4 N NPT R port N3 One-touch fitting for 5/32" A port M5 x 0.8, C4 1/8 T NPTF Note) For more than 8 stations, supply air to both sides of P port and exhaust air from both sides of R port. 667 Manifold specifications
H B C 8mm 12mm 20mm Non-standard motor switch P N S Ground ball screw Rolled ball screw Slide screw Motor output: 100W None N.C. (B contact) 2 pcs.
W = P x S x 0.1 x 1/t W = 1 g = 0.0098 N 0.0098 = P x 0.13 x 0.1 x 1/4 S = P/4 x (0.4)2 = 0.13 cm2 P = 3.0 kPa t = 4 (Horizontal lifting) According to the calculation, 3.0 kPa or more of vacuum pressure can adsorb the workpiece. (3) Based on the workpiece shape and type, select: Pad type: Flat Pad material: Silicone (4) According to the results above, select a vacuum pad part number ZP3-04US
VS7 S kit (Serial transmission) Kit F kit (D-sub connector) T kit (Terminal block) P kit (Flat cable connector) U S F 15 pin U S P 26 pin U S A S U S P 20 pin U S P 16 pin U S P A B C 10 pin F 25 pin T2 T1 Model Max. number 16(1) 14 8 8 16 16 16(1) 14 16(1) Note 1) Due to the limitation of internal wiring.
The labels shown below are used on manifold stations containing SUP/EXH block disk(s) to show their location. (3 pcs. each) L (7.5) VZ3000-123-1A 8 Label for EXH block disk Label for SUP/EXH block disk Label for SUP block disk (35) (25) P R P R P R P R P R 5.5 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors [Rail mounting pitch
Flat pad P. 11 3.5 x 7 4 x 10 4 x 20 4 x 30 5 x 10 5 x 20 5 x 30 6 x 10 6 x 20 6 x 30 8 x 20 8 x 30 W P. 17 Oval pad 3.5 x 7 2 x 4 4 x 10 U H P. 33 HT P. 33 Heavy-duty pad HB P. 35 HW P. 36 U P. 27 Mark-free pad H P. 28 Related pad S Sponge pad P. 30 Resin attachment K P. 29 Pad with ball spline buffer U P. 24 H P. 37 Heavy-duty ball joint pad HB P. 43 Cyclone pad (Non-contact pad) Made
0.02 P.1214 50, 63, 80, 100 0.01 CS2Y 125, 140, 160 0.005 P.1228 REA REB Low Speed Cylinder Low Speed Cylinder CJ2X/CUX/CQSX/CQ2X/CM2X P. 1243 REC Action Series Bore size (mm) Minimum operating speed (mm/s) Page CY CY CJ2X CX CX P.1246 10, 16 1 MQ CUX 10, 16 1 RHC P.1256 20, 25, 32 0.5 RZQ CQSX 12, 16 1 P.1261 Double acting 20, 25 0.5 CQ2X P.1268 32, 40, 50, 63, 80, 100 0.5 CM2X DP.1280 20
Mounting Through-hole Piston speed 5 to 50mm/s 50 to 500mm/s Standard Stroke Note 1) Refer to p.0-43 for precautions. Note 2) For applications involving lateral loads, refer to the "Lateral Load Resistant Style" on p.2.3-118.
Grease pack part number: GR-S-010 (10 g) CS2 Basic (B) P Bore size Stroke 20 25 20 CM2B P P (Head side pressure port) (Head side pressure port) P P (Rod side pressure port) (Rod side pressure port) Effective thread length FL Width across flats B2 Width across flats B1 H1 H2 32 to 40 P Width across flats KA E (Head side pressure port) I G G NA D Q MM NN AL N N F K H A P QY NA ZZ + Stroke S
D D t D t t c e c c e e u u s u s s d i d i d i g g g o o o n n n r r r P P P A A A 1 1 9 9 9 9 9 9 w w 9 w 9 9 m I m I n n 9 9 9 u d u d a a a r u r u o s o F s tr F i e tr i e 9 9 9 D r r D r r r e e e e v v s 1 d d s 1 1 d o o i i n g n g n n n n a a H H n P n P g g r r o o i i s s d d e e u u D D c c t t d A d A r r w w a a 12-11-1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way,
S S S () 0 r / m i n 0 r / m i n L S P L S P O N O N O F F L O F F L S N S N 1 S S S S 0 r / m i n 0 r / m i n L S P L S P O N O N O F F O F F L L S N S N 2 S S S S S S 0 r / m i n 0 r / m i n L S P L S P O N O N O F F L S N O F F L S N 3 S S S S S S S 0 r / m i n 0 r / m i n L S P L S P O N O N L S N O F F L S N O F F 6 39 6 6.4.4 (PC31PC34) PD20 PD20 0 1
p p p m m m m m m m p p p p p p p p m m m m m M m M m R p m p p p m m m M m R m p R M p m p p m p m p M m m m m M m p p M m M p p m m m m p m M M m R m m m p m m p m m p p m p m p m p m m R p m m p m p m m M M m m m m p m m p M m p m p m m m m p m M p p m m R p p p p p p p p R p p p m m p m m R p m p m p m m p M p m m m m p p m p p m p m m p R m p p p R m p p p R p p m m p m m p p p p p p
PG PH U D B C4, N3 C6, N7 C8, N9 1 2 Cassette base manifold: SS5V2-16 D Stations (S, R, RS) When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.