SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-N02-L2-AT"

VX2 24 VDC GDM2A-G-S5 100 VAC VXK 110 VAC 200 VAC VXD None 220 VAC GDM2A-R 230 VAC VXZ 240 VAC 24 VAC VXS VXS 48 VAC 24 VDC GDM2A-G-Z5 100 VAC GDM2A-R-L1 110 VAC GDM2A-R-L1 200 VAC GDM2A-R-L2 220 VAC GDM2A-R-L2 230 VAC GDM2A-R-L2 240 VAC GDM2A-R-L2 24 VAC GDM2A-R-L5 48 VAC GDM2A-R-L5 VXB VXE With light VXP VXR VXH VXF Gasket Part No. for DIN Connector VCW20-1-29-1-F VX3 VXA Bracket Assembly

(Value at the initial state) Impact resistance Conditions when tested with a drop tester in the axial direction and at a right angle to the armature, one time each in energized and deenergized states. No malfunction occurred when tested.

(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.

(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.

(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.

Note 3) The maximum operating pressure is the value at 20C. Refer to the operating pressure curve for other temperatures.

(d) ( FR-BSF01FR-BLF) () 0.5MHz5MHz [mm] 2(AWG12)) (L1L2L3) (UVW) 4 4 2 FR-BSF01(3.5 (110) 95 0.5 25 (22.5) 11.25 0.5 (65) 33 MC MCCB 1 L1 L2 L3 (65) 4.5 (4 ) 2 2(AWG10)) FR-BLF(5.5 MC MCCB 7 L1 L2 L3 31.5 130 7 85 80 35 (4 ) 160 180 2.3 11 23 11. (e) ( FR-BIF) 10MHz 200V: FR-BIF [mm] FR-BIF 4 mA 300 LECSS2-T MC MCCB 29 L1 42 4 5 L2 L3 29 7 58 44 11 24 11.

(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.

(Station n) (Station 1) VVEX4-1 (Internal pilot) 83.3 A A 62.8 47.5 P R 13.5 38.5 P=46 n x Port 2(A): 1/4, 3/8 L Dimensions L1=46n+31, L2=46n+15 n: Stations Station L dimension 2 3 4 5 6 L1 123 169 215 261 307 L2 107 153 199 245 291 1736 VEX3 Series Specific Product Precautions 1 Be sure to read this before handling the products.

Additionally, make the piping work so that the piping lengths (L1 and L2) to two mechanical valves from the air supply also have no significant difference. If the difference between the piping lengths is significant, a time lag occurs during pressure increase of P1 and P2. This may cause the output to malfunction even when operated at the same time.

MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed MHK2-16S 16 23 6 14.6 20.6 114 DL1 MHK2-20S 20 34 10 16 26 237 L2 MHK2-25S 25 58 14 19 33 443 20MHK2-12C 12 12 4 9 13 76 MHK2-16C 16 25 6 14.6 20.6 115 MHK2-20C 20 44 10 16 26 237 MHK2-25C 25 73 14 19 33 443 Series MHKL2/Long Stroke Type Note) Width at opening (mm) L2 Width at closing (mm) L1 Effective gripping force per finger (N)

MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed MHK2-16S 16 23 6 14.6 20.6 114 DL1 MHK2-20S 20 34 10 16 26 237 L2 MHK2-25S 25 58 14 19 33 443 20MHK2-12C 12 12 4 9 13 76 MHK2-16C 16 25 6 14.6 20.6 115 MHK2-20C 20 44 10 16 26 237 MHK2-25C 25 73 14 19 33 443 Series MHKL2/Long Stroke Type Note) Width at opening (mm) L2 Width at closing (mm) L1 Effective gripping force per finger (N)

Order Made Power Saver Power consumption is decreased by 1/3 of standard product by reducing electrical power at holding. (This is effective when energizing time exceeds 62ms at rated voltage of 24V DC.) Specifications Operating principle 1 2 3 4 1 2 3 4 SY1 T SY1 AT SY Series Power consumption at holding is decreased with the below indicated circuit, for energy savings.

Orange Calculation of Connected Plug and Socket Dimension Overall length of connected plug and socket B = Plug (L1 L2) + Socket (L2) + 0.5 Plug Socket Example) Overall length of KK3P-01MS (plug) and KK3S-01MS (socket) when they are connected.

L1 8 VNH L2 4 x 9 (for M8 mounting) VND 2 port valve 3 port valve Cleaning valve + Gate valve < >: Pilot port is C6.

Output 1 Output 2 A B C Dimensions L5 D2 M2 IN L3 L2 L4 OUT IN D1 M1 M1 Applicable tubing O.D. d L1 D3 Metric sizes Weight g Model d D1 D2 L3 L2 D3 L1 L4 L5 M1 M2 3.2 11.4 8.4 52 6.2 25.7 36.1 17.5 12.7 12.9 26.4 VR1211F-23 14.8 4 12.8 10.4 56 26.6 38.5 21.9 15.7 15.8 30.4 VR1211F-04 6.8 6 12.8 12.8 53.2 28.8 41.9 25.2 16.8 16.8 25.0 VR1211F-06 Inch sizes Weight g Model d D1 D2 L3 L2 D3 L1

Output Output 3 B Output 1 Output 2 A B C A B A Dimensions (mm) 1in = 25.4mm 1g = 0.0353 oz D3 Metric sizes: Light gray Inch sizes: Orange D2 L5 M2 IN Blue L3 L2 L4 OUT IN D1 M1 Applicable tubing O.D. d M1 L1 Metric sizes: Light gray Inch sizes: Orange Metric sizes Weight g Model d D1 D2 L3 L2 D3 L1 L4 L5 M1 M2 VR1210F-23 3.2 11.4 8.4 52 6.2 19.4 29.8 17.5 12.7 12.9 21.4 VR1210F-04 4 12.8