SMC Corporation of America
Elite Part Number Search
Search Results "ISE77G-02-L2-S"

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: Orifice shipped with the Product, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

D2 A L2 H Connection threads Union Tee: KPQT, KPGT (M5) H (width across flats) 2-Applicable tubing Effective area mm D1 Model L1 TPH TPS A Note 1) Applicable tubing O.D. mm Connection threads R (M5) Weight g L2 D2 M M L1 M L1 8 10 14 8 10 14 12 14 KPGT04-M5 KPGT04-01 KPGT04-02 KPGT06-M5 KPGT06-01 KPGT06-02 KPGT08-01 KPGT08-02 KPGT10-02 KPGT10-03 KPGT12-03 KPGT12-04 KPQT04-M5 KPQT04-01 KPQT04

D2 A L2 H Connection threads Union Tee: KPQT, KPGT (M5) H (width across flats) 2-Applicable tubing Effective area mm D1 Model L1 TPH TPS A Note 1) Applicable tubing O.D. mm Connection threads R (M5) Weight g L2 D2 M M L1 M L1 8 10 14 8 10 14 12 14 KPGT04-M5 KPGT04-01 KPGT04-02 KPGT06-M5 KPGT06-01 KPGT06-02 KPGT08-01 KPGT08-02 KPGT10-02 KPGT10-03 KPGT12-03 KPGT12-04 KPQT04-M5 KPQT04-01 KPQT04

D2 A L2 H Connection threads Union Tee: KPQT, KPGT (M5) H (width across flats) 2-Applicable tubing Effective area mm D1 Model L1 TPH TPS A Note 1) Applicable tubing O.D. mm Connection threads R (M5) Weight g D2 M L2 M L1 M L1 8 10 14 8 10 14 12 14 KPQT04-M5 KPQT04-01 KPQT04-02 KPQT06-M5 KPQT06-01 KPQT06-02 KPQT08-01 KPQT08-02 KPQT10-02 KPQT10-03 KPQT12-03 KPQT12-04 KPGT04-M5 KPGT04-01 KPGT04

L1 L2 M Nylon Urethane Weight (g) D 1 8 KGF04-01 KGF04-02 KGF06-01 KGF06-02 KGF06-03 KGF08-01 KGF08-02 KGF08-03 KGF10-02 KGF10-03 KGF12-02 KGF12-03 5.6 15 23 11 16 14 11 13 15 17 13.1 13.1 14 27 31 27.5 31 33.5 29 32.5 33.5 34.5 36.5 35 37 41 4 10 5.6 1 4 17 14 17 19 14 17 19 17 19 17 1 8 15 22 25 17 24 24 27 30 36 31 1 4 12 6 3 8 1 8 1 4 3 8 1 4 3 8 1 4 3 8 11 13 14 14 15 8 18.0 18.5 26.1

(mm) Connection thread Rc T (M) Width across flat M Weight (g) Mounting hole L1 L2 Model H1 H2 KQB2E23-02 KQB2E04-01 KQB2E04-02 KQB2E06-01 KQB2E06-02 KQB2E06-03 KQB2E08-01 KQB2E08-02 KQB2E08-03 KQB2E10-02 KQB2E10-03 KQB2E12-03 KQB2E12-04 KQB2E16-03 KQB2E16-04 3.2 3.4 1/4 1/8 1/4 1/8 1/4 3/8 1/8 1/4 3/8 1/4 3/8 3/8 1/2 3/8 1/2 17 14 17 11 12 31 25.8 30.9 24.2 31.6 33 26.3 32.4 34 31.6 33.6

D2 A L2 H Connection threads Union Tee: KPQT, KPGT (M5) 2 x Applicable tubing Effective area mm2 D1 Model L1 TPH TPS A Connection thread R M H (width across flats) (M5) Note 1) Applicable tubing O.D. mm Weight g L2 M D2 M L1 M L1 D1 8 10 14 8 10 14 12 14 KPGT04-M5 KPGT04-01 KPGT04-02 KPGT06-M5 KPGT06-01 KPGT06-02 KPGT08-01 KPGT08-02 KPGT10-02 KPGT10-03 KPGT12-03 KPGT12-04 KPQT04-M5 KPQT04

Stations 02 Symbol Port size Applicable series 1/4 3/8 1/2 02 03 04 VPA300 VPA500 VPA700 2 stations 20 20 stations Manifold Option Description Part no.

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)

L3 L4 2.10-15 VQZ100/200/300 Body Ported VQZ300 VV3QZ32C Station C10: One-touch fittings for 10 C8: One-touch fittings for 8 C6: One-touch fittings for 6 n-C6, C8, C10, 02 (35) 33 (11) 2-4.5Mounting holes DIN rail clamp screw (5.5) Grommet (G) (7.5) 24 (2.5) U side 02: Rc(PT)1/4 n Manual override 5 A A A A 4 2 2 2 2 (L4) (L3) L2 L1 3 2 P=19 1 21 6 Stations D side 1.8 (C6, C8) 17.5 3.5 20.5