SMC Corporation of America
Elite Part Number Search
Search Results "JA100-26-150"

Refer to p.0-26 and 0-27 for Safety Instructions and common precantions on the products mentioned in this catalog, and refer to p.4.0-5 to 4.0-7 for precantions on every series. Please refer to p.4.5-7 for with pressure differential gauge (GD40-2-01). 4.6-6

No.PS-OMR0001CN-J // ISA3 1 2 7 8 14 15 2 (ISA3) 15 () 16 (2 ) 16 17 20 26 26 29 34 38 3 41 42 44 44 44 45 45 4 46 46 46 () 58 59 60 5 61 62 62 -1No.PS-OMR0001CN-J 1 (ISO/IEC)(JIS) 1) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety

180 Flange Type Port size: 65F, 80F Electrical entry hole: G1/2 Manual override (Non-locking) 4 x 2-18 mouting hole (80F: 8 x 2-18) Model Applicable flange 65 80 H F E D C B A 1 4 1 4 405.5 441.5 VNC81 -65F VNC91 -80F 65 80 140 150 204 235 175 185 305.5 341.5 210 240 17-4-26 7 Series VNC Coolant Valve: Air Operated/External Pilot Solenoid Precautions Be sure to read before handling.

Finger closing port 14 14 Finger opening port M3 x 0.5 2-4.5 D0.8 0.8 E-E Close: 0 +0.1 0 20Open: 161 Use the attached hexagon socket head screws for mounting holes. 4-M3 x 0.5 thread depth 4 26 4-M2.5 x 0.45 thread depth 3 Attachment mounting thread Mounting thread Auto Switch Mounting Groove Dimensions M2.5 x 0.45 4 1.3 12 26 15 4 Accessory option: Hexagon socket head screw (special screws

26 26 3H9 +0.025 0 depth 3 MHZ MHF MHL 4-M4 x 0.7 thread depth 10 MHR 4 4 94 Mounting thread MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-M4 x 0.7 thread depth 5 M5 x 0.8 Finger closing port Mounting thread MHS 40 104 MHC 90 20 MHT E 7.7 MHY 14.8 15 19 25

35 47 N 8.4 8 10.5 Q 2.3 2.3 2.3 L 22 23 26 P 40 53 70 W 34.5 41 A NPT 1/4 NPT 3/8 NPT 1/2 C 40 53 70 F 40 53 70 E 10 14 18 G 57 73 H 18 16 17 J 30 41 50 T M4 X 0.7 M4 X 0.7 M5 X 0.8 K 27 40 54 S 32 44 60 AF20 AF30 AF40 Auto Drain mm Dimensions Mounting Bracket Kit (Optional) AF30P-050AS-X480 AF40P-050AS-X480 Model Port Size D 158 194 M 6.5 8.5 R 35 47 N 8 10.5 Q 2.3 2.3 L 23 26 P 53 70

PV SV HRS Series 5.18 Communication function 5-59 HRX-OM-R016 Chapter 5 Display and setting of various functions 26. Select response delay time (simple communication protocol) from the table below with [] key or [] key, and confirm by pressing SEL.

PV SV HRS Series 5.19 Communication function 5-59 HRX-OM-W038 Chapter 5 Display and setting of various functions 26. Select response delay time (simple communication protocol) from the table below with [] key or [] key, and confirm by pressing SEL.

Hs 8.5 16 16 A 26 B Auto switch A 29 (36) B Dimensions inside ( ) are for D-H7LF. D-C73C, D-C80C D-H7C Approx. Hs Approx. Hs 8.5 8.5 Auto switch Auto switch 16 16 A 36.7 B A 38.2 B D-B5, D-B6, D-B59W D-A3, D-G3, D-K3 Approx. Hs Auto switch 36 Approx.

) 258-9200-www.stevenengineering.com (3-NPT1/4) 3-Rc1/4 M5 x 0.8 Pilot port Breathing port M3 x 0.5 PB 13 46 PA 72 41 22.5 30 6.5 52.5 2-M5 x 0.8 Depth 6 20 17-5-26 24 Manually Operated Series LVH How to Order Valve (Single Type) VC Applicable tubing size Body class Body class 2 3 4 Connecting tubing O.D.

PV SV 5.21 Communication Function HRS Series 5-74 HRX-OM-W032 Chapter 5 Display and Setting of Various Functions 26. Set responce delay time (simple communication protocol) with [] key or [] key, and press [SEL] key to enter.

-01-3--F P = 26 (Applicable cable O.D.)

The terminal number indicated in the connection schematic of connector, as show in the reference, means a correlation of 1, 2, 3 26 from the triangle mark side on the flat cable of connector. 24 25 26 Reference For more than 10 stations, both poles of the common should be wired. For single solenoid, connect to the solenoid B side. The maximum number of stations is 12.

800/220 1200/350 / AC200V 2400/150 3200/220 4800/350 Ass'y XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 Ass'y 2 3 4 H5 AC100V 800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1)/ 2)16 PTC() 200V 200 PTC 150 100V PTC Ass'y 0 5 10 15 20 25 30 Ass'y ( Ass'y 30 8 XL-OMV0002 4 4-1.162540 Assy SUS304 SUS316L ( SUS304) ( A6063) C D C E E (KF ) Fn J H B A G A mm A B C

800/220 1200/350 / AC200V 2400/150 3200/220 4800/350 XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 2 3 4 H5 AC100V 800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1 PTC 200V PTC 200 150 100V PTC 0 5 10 15 20 25 30 ( 30 10 XL-OMY0002 . 1 S 12 ( SUS304 M 3 M SUSU316L 8 11 SUS304 2 7 A6063 6 9 6 9 10 9 5 SUS304 4 5 10 4 10 S O S O XLD-25 XLD-40,XLD-

Refer to p.0-26 and 0-27 for Safety Instructions and common precautions on the products mentioned in this catalog, and refer to p.4.0-5 to 4.0-7 for precautions on every series. ORIENTATION Design Caution q Design the layout so that the mist separator is installed in an area that is less susceptible to pulsations.

Micromist separator AMD900, 1000, 901 Model Connect (Flange) 2B 2B/3B/4B 400 A 280 B 6B C 550 D 150 E 270 F 823 G 3 H 797 J 620 AMF801 AMF901 445 12B 570 300 520 1093 3 867 AMF800/900/1000 Mounting Caution q Verify the direction of the flow of the compressed air and the "e" mark that indicates the inlet of the product before connecting.

L dimension 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 VS VFN Silencer (For manifold EXH port) Silencer is installed in the EXH port. 63 38 22 Dimensions 13 Silencer part no.