Store away from direct sunlight at 40C or less. 2. Open the inner package of double packaging in a clean room or other clean environment. 12 to 14 R 1/4 22 to 24 R 3/8 28 to 30 R 1/2 Mounting 3. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. Position the wrench on the base as close as possible to the threads.
Evaluation criteria for ozone resistance SMC's evaluation criteria for ozone resistance in its products can be defined as follows: Products meeting a 5-year (or 43,800 hours) resistance rating (or equivalent) under working conditions that include 40C ambient and fluid temperatures and an ozone concentration of 0.03ppm in 0.5MPa compressed air.
Min. bending radius (mm)(2) 10 15 20 27 35 10 Operating temperature 0 to 40C Burst Pressure Characteristics Curve Conductive polyurethane Material 104 to 107 Surface resistance Note1) Refer to burst pressure characteristics curve for other temperatures. Avoid abnormal temperature rises. Note2) The value at temperature of 20C.
Store away from direct sunlight at 40C or less. 2. Open the inner package of double packaging in a clean room or other clean environment. 12 to 14 R 1/4 22 to 24 R 3/8 28 to 30 R 1/2 Mounting 3. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. Position the wrench on the base as close as possible to the threads.
Store away from direct sunlight at 40C or less. 2. Open the inner package of double packaging in a clean room or other clean environment. 12 to 14 R 1/4 22 to 24 R 3/8 28 to 30 R 1/2 3. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. Position the wrench on the base as close as possible to the threads.
weight Output signal capacity Open drain output (Max.30 VDC or less, Max. 20 mA) Nominal size Basic weight Emergency stop, Output deviation, Power supply deviation, Driving deviation, Temperature deviation Stroke deviation, Motor deviation, Controller deviation Emergency detection items 16 2.24 0.14 0.01 General Specifications 25 3.95 0.21 0.02 How to calculate/Example: E-MY2C25-300TAN 5 to 40C
GXL-8F GXL-8FI GXL-8FB GXL-8FIB GXL-8FU GXL-8FUB N.O (A contact) N.C (B contact) AC servomotor (30w) Motor N.C (B contact) N.O (A contact) Lead screw Positioning repeatability Lead Speed Ball screw 8mm 0.03mm 2mm 50mm/s 10 (4)kg 5 (4)kg N.C (B contact) Refer to page 318 for detailed specifications of proximity switches. 5mm 100mm/s 10 (4)kg 5 (4)kg High rigidity direct acting guide 5 to 40C
Example) LXPBABC-100SB-F9N1F9G1-X12 Brake Home position switch Note 2) Without brake With brake Nil B None Yes (cable length 0.3m) Nil S Specifications Motor AC servomotor (30w) Lead screw Positioning repeatability Ball screw 8mm 0.03mm Lead Speed 2mm 50mm/s 5mm 100mm/s Horizontal Vertical 6kg 5kg 6kg 5kg Ball bushing 5 to 40C (with no condensation) Work load Guide type Operating temperature
Front matter 5 (4) Test method By attaching the equipment for testing with the test circuit shown in Fig. (3) and running water at 5 to 40C, measure the flow rate with a pressure difference of 0.075 MPa. However, the pressure difference needs to be set with a large enough difference so that the Reynolds number does not go below a range of 4 x 104.
Fluid 5 to 40C (41 to 104F) Operating temperature C 0.2M to 1 x 10 -6 {1.5k to 7.5 x 10 -9} Operating pressure Pa {Torr} 5 8 5 8 Conductance l/s 1.3 x 10 -8 {1 x 10 -7} at ordinary temperatures, excluding gas permeation 1.3 x 10 -11 {1 x 10 -10} at ordinary temperatures, excluding gas permeation Internal External Leakage Pa m3/s {Torr l/s} KF16 KF25 KF16 KF25 Flange type/size Principle materials
Series IDF can accommodate an inlet temperature of 40C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger.
Products are tested from -40F to 200F (-40C to 93C) per FMVSS 49CFR571.106. How to Order TIV 07 B 33 Length per Roll Conversion 33 77 153 305 Tube Model Feet Feet Feet Feet Meters 33 77 153 305 108 252 500 1000 Meters Meters Meters Meters = = = = See Packaging Table below. Not Available in all sizes and all colors.
Operating Pressure Specifications Fluid Air/Water 20C 0.8 5.0 Max. operating pressure (MPa) 40C 0.65 Max. operating pressure (MPa) 4.0 60C 0.5 Applicable fittings FR one-touch fittings: KR-W2 series 3.0 Ambient and fluid temperature 20 to +60C Water: 0 to 40C (No freezing) Internal tubing Polyurethane 2.0 Material Outer layer Polyolefin (Equivalent to UL-94 standard V-0) Note) The color of
Operating Pressure Max operating pressure (MPa) 40C 0.65 60C 0.5 Applicable fittings One-touch fittings 5 Max. operating pressure (MPa) Min. bending radius (mm) 18 24 30 36 10 4 Operating temperature 20 to 60C Material Polyurethane 3 How to Order 2 1 TUH0644 B 20 0 -20 0 20 40 60 Operating temperature (C) Length per roll Tubing model Length 20 m roll 100 m roll Symbol 20 100 Precautions Be
Measure 2R when the tube breaks or is crushed. 40C 0.65 60C 0.5 Fixed end One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Applicable fittings Min. bending radius (mm) 4 10 15 20 27 35 10 15 23 27 35 45 20 to +60C (Water: 0 to 40C) (No freezing) Operating temperature Material Polyurethane 465 TU/TIUB Series How to Order 20 TU0425 BU Length per roll Tubing model
Grease Grease-free R Clockwise L Counterclockwise Body material A2017 Weight (g) 12.5 49 114 206 310 * Air purication rating: JIS B 8392-1 (ISO8573-1) Quality Degree 4, 4, 2 or more 2A 3A Low profile cyclone type Outer body diameter (mm) 20 25 Piping port size 1.6 Fluid Air* XT661 X260 2A R Operating pressure 0.01 to 0.5 MPa Proof pressure 0.75 MPa Ambient and operating temperature 5 to 40C
The HAA can cool high temperature compressed air from compressors down to 40C or less while efficiently removing moisture from the air.? The series does not require cooling equipment, and is free from concerns such as water supply cut-off or freezing.?
MHZ2-40C, ACTUATOR, MHZ2 GRIPPER, PARALLEL, M1, 40MM MHZ2, 1.54880 lb
The HAA can cool high temperature compressed air from compressors down to 40C or less while efficiently removing moisture from the air. The series does not require cooling equipment, and is free from concerns such as water supply cut-off or freezing.
The HAA can cool high temperature compressed air from compressors down to 40C or less while efficiently removing moisture from the air. The series does not require cooling equipment, and is free from concerns such as water supply cut-off or freezing.