52.5 + Stroke 68 + Stroke 32 4-M5 x 0.8 depth 8 10 + Stroke 15 20 Stroke (mm) LT NS LB J LA 5 20 64 4 10 10 20 10 64 4 15 74 25 20 4 20 74 25 4 20 25 40 84 4 30 30 40 30 84 4 40 20 94 50 20 6 50 104 70 25 6 25 60 70 114 6 30 30 36 Compact Slide MXH Series Auto Switch Specifications Auto Switches/Proper Mounting Position for Stroke End Detection A 22 D-A9 D-F9 D-F9 W B W 20 (22) A
Size 25 32 40 50 l 18.2 22.2 26.2 32.2 Size 25 32 40 50 Part no.
50 5 0 Z X Mass and center of gravity of the load 25 Center of gravity 50 Load no.
6 w i o !7 !5 Open Component Parts Component Parts Description Material No. Note No. q w e r t y u i Description Material Note Body 20, 25: Resin Aluminum alloy Hard anodized Cap o Piston 32 to 50: Aluminum alloy Hard anodized Stainless steel Nitriding Pinion gear Carbon steel Shield type Carbon steel Heat treatment Ball bearing !0 !1 !2 !3 !4 !
Construction Component Parts Description No. q w e r t y u i o !0 !1 !
With (1) Without (1) Coil voltage 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC Others (1) With With (Without light) 1 (1) 2 Note 1) DIN is applicable to VQZ 200 and 300.
With double locks: CBG1BN Bore size Stroke W (mm) Bore size (mm) S ZZ 20 92 129 25 92 134 32 91 133 40 101 153 50 119 179 63 119 179 S + Stroke 80 146 220 ZZ + Stroke 100 146 220 With rod boot IJ e JH 8 l f h + l JW ZZ + l + Stroke (mm) Front lock (-R) ZZ Double locks (-W) Rear lock (-H) Bore size (mm) e f h IJ JH JW l ZZ ZZ 20 30 16 55 27 (14.5) (11.5) 138 137 (145) 149 25 30 17 62 32
650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 14 (2, 4 port) 112 93 12 Y 25 (14 port) PE port 5 3 37 25 22 14 1 25 25 9 1/8 12 port 3/8-2 port 3, 5 port 1/4, 3/8 1 port 14 port 1/8 1/4, 3/8-2 port 2, 4 port EVS7-6-FG-D-M0 EVS7-6-F G-D-M0 H J I 186 196 89 89 13 (4 port) 50 50 13 (2 port) 13 (4 port) 50 50 13 (2 port) B A B A 50 62 50 62 38 14 38 12 14 12 Manual
w w t t t q q q e IN OUT IN OUT IN OUT y y y e e r r r u u u Drain Drain Drain Parts list Material No.
(Values at the initial period) Solenoid Specifications Electrical entry Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 12, 24 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz 3.5 VA/50 Hz, 3.3 VA/60 Hz 3 VA/50 Hz, 2.8 VA/60 Hz 4 W (Standard), 2 W (Low power consumption type) 4.3 W (Standard), 2.3 W (Low power consumption type) Varistor Diode (Varistor for 12 VDC
Operating pressure range 101.2 kPa to 0.1 MPa Apparent power/AC Inrush Holding 7.9VA (50 Hz) , 6.2VA (60 Hz) 5.8VA (50 Hz) , 3.5VA (60 Hz) Power consumption/DC 2 W, 2.2 W (With indicator light) 30 ms or less (at the pressure of 0.5 MPa) Response time (1) Note1) Refer to Response time of standard specifications.
Applicable air cylinder bore size 18 6.8 16 6 42 6.5 10 YA-03 32, 40 20 9 20 8 50 6.5 12 YA-05 50, 63 26 11 25 10 62 8.5 16 YA-08 80 32, 40 50, 63 80 100 03 05 08 10 Mounting bracket 31 14 30 12 76 10.5 18 YA-10 100 A type mounting bracket YA YB YU Bore size (mm) B type mounting bracket Joint Weight (g) W V U Part no. 56 55 18 6 32, 40 YA-03 67 100 22 8 50, 63 YA-05 83 195 28 10 Allowable
(Values at the initial period) Dustproof Solenoid Specifications Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 12, 24 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz Electrical entry AC DC Rated voltage (V) Base mounted Allowable voltage fluctuation Inrush Holding Apparent power (AC) Diode (12 VDC or less: Varistor) Varistor 4.3 W (Standard), 2.3 W (Low wattage
SW Enable SW SW 12 Unit name W 1 W-AREA1 W 1 AREA ON (mm) W 12 AREA ON + *W 1>=W 2 ,PARA W 1=W 2=0 AREA OFF W 2 W-AREA2 W 2 + ORG Correct * Sensor type * 1 (CC-Link () 1 (CC-Link ) ) () Option 1 1 (1 ) 14 (Occupied number of stations of CC-Link) 2 (2 ) 4 (4 ) CC-Link (CRC ) 11 CC-Link 11 CC-Link CC-Link 0 () UndefineN o.11 0,10 (Operation setting at CC-Link communication
5 OUT side passage IN q IN q w y Bleed Bleed !1 !3 !2 e w r Exhaust SUP(1) OUT(2) SUP(1) OUT(2) u !0 !2 !0 t Valve guide Valve guide Replacement Parts IR100 IR200 IR300 IR2120 IR3120 Part no. No.
Power consumption (W): For AC, W = VAcos. For DC, W = VA. Note) cos shows power factor. cos 0.9 3. Symbol When the valve is closed, flow is blocked from port 1 to port 2. However, if the pressure in port 2 is higher than port 1, the valve will not be able to block the fluid and it will flow from port 2 to port 1. 2.
7 It is used only in the case of w/ cushion type.