SMC Corporation of America
Elite Part Number Search
Search Results "MXY12-250"

Lx = 250 mm, Ly = 180 mm, Lz = 1000 mm 4.

Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.

Ethernet POWERLINK 2 A Plug-in Compact 5-Port Solenoid Valve JSY1000/3000/5000 Series The EX600-W series is compatible with wireless systems. p. 63 MNoise resistance MHigh-speed connection MCommunication response Uses the 2.4 GHz ISM frequency band Frequency hopping: Every 5 ms Wireless communication signal Response time: 5 ms From the remote power supply ON to start of communication: Min. 250

(Rail mounting hole pitch 12.5) (Station n) (Station 1) Block separation lever (DIN rail dimension) (mm) (Push type) 2 stations 3 4 5 6 7 8 9 10 stations Stations n L1 L2 L3 L4 273 260.5 260.5 248 235.5 223 210.5 198 198 262.5 250 250 237.5 225 212.5 200 187.5 187.5 175.5 165 154.5 144 133.5 123 112.5 102 91.5 12.5 11.5 17 16 15 14 13 12 17 SS5X3-45S3DStations BC4 C6 Note) The L1 to L4 dimensions

Bore Size: 12mm, Stroke: 400mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: Z (5m)

Bore Size: 12mm, Stroke: 400mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 4 pcs.

Bore Size: 12mm, Stroke: 400mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 12mm, Stroke: 200mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal

Bore Size: 12mm, Stroke: 150mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 12mm, Stroke: 150mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Bore Size: 12mm, Stroke: 400mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 12mm, Stroke: 200mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Bore Size: 12mm, Stroke: 150mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal

Bore Size: 12mm, Stroke: 200mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)

Bore Size: 12mm, Stroke: 400mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector)

The MXY series is a long-stroke type of the series MXP air slide table. The MXY comes with a built-in magnetically coupled rodless cylinder. Integrated with a linerar guide, the MXY provides a rigid, compact and lightweight design. "Cylinder. GUIDED CYLINDER. N lb. MXY.

Bore Size: 12mm, Stroke: 50mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical

Bore Size: 12mm, Stroke: 100mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc.

Bore Size: 12mm, Stroke: 100mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 12mm, Stroke: 150mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -