SMC Corporation of America
Elite Part Number Search
Search Results "NCDJ2L10-600-B"

500 100 200 300 400 600 Load (N) Load (N) Load (N) 8-7-5 6 Long Stroke Slide Table Series MXW 8, 12, 16, 20, 25 How to Order MXW 16 100 B M9N S Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.

(OUT) Metric size None Bracket Nil B G ARJ310-01 4 mm 6 mm 04 06 Pressure gauge Note 2) For products with pressure gauge, pressure gauge is shipped together with product.

0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure 0.2MPa Flow rate Q = 20l/min (ANR) 0.30 Downstream pressure MPa 0.25 Starting point 0.20 0.15 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Upstream pressure MPa Construction ARJ310-01 ARJF310F-01 y

(ZS-24-B) W1: Rc1/8 01: R1/8 (with M5 female threads) T1: NPT1/8 (with M5 female threads) Rc1/8 Reverse pressure two directions B R1/8, NPT1/8 M5 x 0.8 female threads Panel mount (ZS-22-A) Rc1/8 E M5: M5 x 0.8 (female threads) C4: With 4 One-touch fitting C6: With 6 One-touch fitting Wall mount Wall mount Panel mount + Front protective cover (ZS-24-C) M5 x 0.8 F 4, 6 One-touch fitting

(ZS-24-B) W1: Rc1/8 01: R1/8 (with M5 female threads) T1: NPT1/8 (with M5 female threads) Reverse pressure two directions B R1/8, NPT1/8 Rc1/8 M5 x 0.8 female threads Panel mount (ZS-22-A) Rc1/8 E * M5: M5 x 0.8 (female threads) * C4: With 4 One-touch fitting * C6: With 6 One-touch fitting Wall mount Wall mount Panel mount + Front protective cover (ZS-24-C) M5 x 0.8 F 4, 6 One-touch fitting

D-A7lH, A80H D-A73C, A80C D-F7l, J79 D-F7lV, J79C D-A79W D-F9l D-F9lV D-F9lWV D-F9lW D-F9BAL D-P5DW D-A9l D-A9lV D-A7, A8 Model B 6.5 7 6 8.5 11.5 14.5 A 28.5 29 33 24 28.5 28.5 B 7 7.5 6.5 9 12 15 B 4 4.5 3.5 6 9 12 B 11 11.5 10.5 13 16 19 B 4.5 7.5 10.5 B 5 7.5 10.5 13.5 B 9 11.5 14.5 17.5 A 34.5 25.5 30 30 B 8 10.5 13.5 16.5 A 19.5 24 24 A 28 28.5 32.5 23.5 28 28 A 25.5 26 30 21

Local Area: (800) 258-9200-www.stevenengineering.com Pump chamber B Pump chamber A Check valve Shaft Suction port (FLUID IN) Diaphragm B Diaphragm A Drive chamber A Drive chamber B Control unit 1.

Applicable model Rated current [A] Sensitivity of leak current [mA] Short circuit display method HRSH100--20-B 30 Earth leakage breaker HRSH150--20-B HRSH200--20-B 40 HRSH250--20-B 50 HRSH300--20-B 30 Mechanical button * 400 V type is equipped as standard.

Side support B MY-SB Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-J C D A B (mm) A 61 70 87 B 75 84 105 C D E F G H J Part no.

Side support B MY-SB 2-J C D A B (mm) A 61 70 87 B 75 84 105 C D E F G H J Part no.

x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8m/s] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Guide central axis Cylinder

(mm) A B C D E F G H J L Port size Bracket part no.

B) Under the above conditions, adjust shim so that the space between the workpiece and the clamping block is about 0 mm. Theoretically there is no clamping force for holding a workpiece under this condition. C) In order to generate clamping force from the state described in step B, insert additional shim.

Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT325 VT325V (Vacuum spec. type) VT325 VT325V (Vacuum spec. type) 0.55 kg (For AC) 0.60 kg (For DC) Note) Values for a single valve unit.

x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8 m/s2] M2 M1 M3 m x g m x g Guide shaft mounting surface Guide central axis m x g Cylinder

CNS D-H7C D-B5, D-B6, D-B59W CLS HS HS Auto switch Auto switch 12 8.5 CLQ 24.5 16 MLGP A B A B 33 38.2 RLQ MLU Proper Auto Switch Mounting Position Auto Switch Mounting Height ML1C Auto switch model D-C7/C80 D-H7 D-H7W D-H7NF D-H7BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7/C80 D-C73C D-C80C D-B5/B64 DD-B5/B64 D-B59W D-G5NTL D-H7C D-C73C D-C80C D-G5NTL D-B59W -X Bore size (mm) A B A B A B A B

H4 S y m b o l Initial power / Power consumption (W) 100 VAC 200/40 200/50 400/100 600/150 200 VAC 800/40 800/50 1600/100 2400/150 Heater assembly number XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 XL1A25-60S-3 XL1A25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs.

-1.8WDC WF333O Exhaust Conter NVF343O GNced Center (B) (A) (B) (a) 01 c2 \ t \ T I'f E I J E Z (R2)(PxFl) (R2XPXR1) Prssure Center NVF3530 (B) (A) Spej;ifications -, Flurd-Art f Operatangprssurcrange2Positionsingle2O-12gPSlS(1.5-9kgF) U 2 pooition double-1 5 1 28 PSI (1 9kgf/cm'?

Outside Inside the controller 10k (a) 1k (a) IN0 to SVON (b) (b) COM Caution Unused input terminals should not be in an unconnected (open) state.