Recommended proper torque Nm Connection threads 1/2 M5 1/8 1/4 3/8 3/4 1 28 to 30 1.5 to 2 7 to 9 12 to 14 22 to 24 28 to 30 36 to 38 Torque 2. Twisting moment or bending moment other than the dead weight of the equipment should not be applied. To avoid damage, external piping should be supported separately from the product. 3.
Recommended proper torque Nm Connection threads 1/2 M5 1/8 1/4 3/8 3/4 1 28 to 30 1.5 to 2 7 to 9 12 to 14 22 to 24 28 to 30 36 to 38 Torque 2. Twisting moment or bending moment other than the dead weight of the equipment should not be applied. To avoid damage, external piping should be supported separately from the product. 3.
Recommended tightening torque Unit: Nm Connection thread 3/4 28 to 30 1/8 7 to 9 1/4 12 to 14 3/8 22 to 24 1/2 28 to 30 1 36 to 38 Torque 5-8-23
B C d H MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M NTJ-015A NT-015A NT-02 NT-03 NT-04 8 9.2 6 15.5 5 9.2 M5 x 0.8 4 10 20.5 10 8 8 9.2 8 16.5 6 11.5 M6 x 1.0 5 16 22.5 16 10 8 9.2 10 18.5 6 15 M8 x 1.25 5 20 24.5 20 13 10 11.5 12 22.5 11 19.6 M10 x 1.25 6 25 33.5 25 17 14 16 16 28.5 12 25.4 M14 x 1.5 8 30, 40 40.5 30, 40 22 Applicable bore size (mm) Part no.
Copper Tube Where corrosion, heat resislance and high rigidity ar required, coppertubing up to a nominal diameter of 40 mm can be used, but will be relatively costly ovet 28 mm. Dia. Compression fittings used with annealed quality tubing provide easy working tor installation.
Copper Tube Where corrosion, heat resislance and high rigidity ar required, coppertubing up to a nominal diameter of 40 mm can be used, but will be relatively costly ovet 28 mm. Dia. Compression fittings used with annealed quality tubing provide easy working tor installation.
A B C D VXA22 52 60 02 03 , 1 4 3 8 22 11 67 77 27 VXA226 -04 2 0 1 2 28 14.5 73 83 30 Fixing with thread is also possible. 4.1-61 VVXA21/22 How to Order/Manifold VXA22 VXA21 00 Model Connection 00 (No connection screw) For manifold Select a model from the highest operating pressure difference and the characteristic figure of flow rate in p.4.1-60 Options Select an option symbol by "Applicable
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12
Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
Stations 02 2 stations IN port direction ... ...
LVQ Model VXA212 VXA213 VXA21 VXA22 VX070-020 LQ 1 8 1 4 1 4 3 8 1 2 01 ( / ) 02 ( / ) 02 ( / ) 03 ( / ) 04 ( / ) VXA223 VXA224 VXA225 VXA226 VX070-022 LVN VX070-029 TI/ TIL PA Ordering example (Example) Series VXA21, Orifice size 4.5 mm, Normally closed, Rc 1/4 (Part no.) VXA2130-02 PAX PB 17-3-95 4 The VX series will be revised shortly.
E 3 Auto-drain Pressure gauge mounting Port size 02 03 04 06 10 ARJ MR unit 1 None With auto drain 0 Flow direction: Right to left Nil Flow direction: Left to right Applicable model 1/4 3/8 1/2 3/4 1 Nil E2 E3 E4 E6 E10 R 3 4 5 6 AMR3 00-02 to 03 AMR4 00-02 to 04 AMR5 00-04 to 06 AMR6 00-10 AR425 to 935 Adapter assembly port size (2 pcs.)
L1 L2 L3 L4 L5 L6 L7 L8 D Model Bore size ASS AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 40 56 30 30 45.5 5 5 5.25 17 23 25 10 11.5 13.2 15.5 17 20.6 54.5 56 68 50 51.5 61 16 20 26 4.5 4.5 5.5 1 4 1 4 ASR Effective thread depth 6 8 3 Dimensions: AS5000 ASF 2-1/4 to 1/2 2-M4 x 0.7 Effective thread depth 7 15-9-31
Type 40 Applicable solenoid valve SYJ514-SYJ514M-SYJ524-SYJ524M-How to Order SS3YJ5--40-05 -M5 R port 1/8 P port 1/8 P, R port thread type Stations A port size 02 : 20 2 stations : 20 stations Applicable blanking plate assembly SYJ500-10-3A Nil A A Rc G NPT NPTF M5 01 M5 x 0.8 1/8 F N T A port M5 x 0.8, 1/8 Note) For more than 9 stations, supply air to both sides of P port and exhaust air
-L2 0x0013 (19) 0 R ID ISE70G-02-L2 0x0014 (20) 0 R Pressure sensor 8 0x0015 (21) 0 R No.
L 21 22 23 24 25 26 27 28 29 30 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 No. L 31 32 33 34 35 36 37 38 39 40 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 No.
Bonnet Common IN Individual IN Common IN Individual IN Polyacetal 2 Regulator Regulator ARM2500-A-02 ARM2500-B-02 ARM3000-A-03 ARM3000-B-03 9 1 Replacement Parts End plate R 10 1 Description Material Part no. End plate L 11 1 No.
32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.