Mounting: A (Both Ends Tapped), Bore Size: 40mm, Thread: TN (NPT Thread), Full Stroke: 250mm, First Stroke: 240mm
Mounting: A (Both Ends Tapped), Bore Size: 40mm, Thread: TN (NPT Thread), Full Stroke: 250mm, First Stroke: 10mm
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250/170, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket
Mounting: Both Ends Tapped, Bore Size: 40mm, Thread: NPT Thread, Full Stroke: 250mm, First Stroke: 240mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Mounting: Both Ends Tapped, Bore Size: 40mm, Thread: NPT Thread, Full Stroke: 250mm, First Stroke: 10mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches
L3 (1) Model Port size Max. 1 4 1 2 120 150 AS800 AS900 74 93 204 262 192 250 80 94 1 1 , 2 Note 1) L3: Reference dimensions Note 1) L3: Reference dimensions 655
Vibration resistance allows for normal operation up to 30 m/s2 (45 to 250 Hz), but continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibrations or shocks. I High-temperature type (H0, H4, H5) 1. For models with a heater, take care not to damage the insulation components of the lead wires and the connector section. 2.
OUT 241 402 563 IN 317 528 739 Unit: g Without Auto Swtich 40 OUT 377 628 880 Cylinder stroke (mm) Bore size (mm) IN 495 825 1150 10 60 80 100 125 150 5 15 20 25 30 35 40 45 50 50 OUT 589 982 1370 20 228 254 306 357 422 487 124 111 137 150 163 176 189 202 215 IN 841 1400 1960 25 292 323 386 448 526 603 168 152 183 199 214 230 246 261 277 63 OUT 935 1560 2180 32 451 495 584 673 785 896 273 250
Stroke (mm) Model 60 40 30 25 20 15 10 5 50 70 80 90 100 27 (32) 30 (40) 34 (44) 37 (47) 40 (50) 44 (54) 51 (61) 58 (68) 65 (75) C(D)UW6-D 44 (49) 49 (59) 53 (63) 58 (68) 62 (72) 67 (77) 76 (86) 85 (95) 94 (104) C(D)UW10-D 74 (99) 81 (111) 88 (118) 95 (125) 102 (132) 109 (139) 123 (153) 137 (167) 151 (181) C(D)UW16-D 132 (165) 145 (182) 158 (195) 171 (208) 184 (221) 197 (234) 223 (260) 250
sensor (mm) Ionizer 600 mm Feedback sensor Installation height of feedback sensor Charged plate 640 A Series IZS31 Technical Data 3 Static Neutralization Characteristics 4) Flow rate Pressure characteristics Position Detection Switch Flow Sensor Pressure Control Pressure Sensor 0.7 300 380 620 780 0.6 1100 Supply pressure (MPa) 0.5 1260 1500 0.4 1900 0.3 2300 0.2 0.1 0 0 50 100 150 200 250
Material: T (SCS14 Cover, SS 316 Case, Fluororesin Gasket/O-ring, Fluororesin Seal), Element Length: A (ℓ250), Port Size: 06 (3/4 Rc), Element Type: B (Sintered Metal, Bronze Material), Nominal Filtration Accuracy: 120 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: B [ℓ500 (ℓ250 x 2)], Port Size: 06 (3/4 Rc), Element Type: B (Sintered Metal, Bronze Material), Nominal Filtration Accuracy: 120 μm, Element Seal Material: N (NBR)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: B (Sintered Metal, Bronze Material), Nominal Filtration Accuracy: 120 μm, Element Seal Material: N (NBR), Accessory: B (Bracket), Made to Order: X77 (Differential Pressure Indicator)
Seal), Element Length: A (ℓ250), Port Size: 04 (1/2 Rc), Element Type: S (Sintered Metal, Stainless Steel Material), Nominal Filtration Accuracy: 120 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)
Material: E (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon/Fluororesin Seal), Element Length: A (ℓ250), Port Size: 06 (3/4 Rc), Element Type: S (Sintered Metal, Stainless Steel Material), Nominal Filtration Accuracy: 120 μm, Element Seal Material: T (Fluororesin), Accessory: B (Bracket)
Material: T (SCS14 Cover, SS 316 Case, Fluororesin Gasket/O-ring, Fluororesin Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: B (Sintered Metal, Bronze Material), Nominal Filtration Accuracy: 120 μm, Element Seal Material: T (Fluororesin), Accessory: B (Bracket)
Material: T (SCS14 Cover, SS 316 Case, Fluororesin Gasket/O-ring, Fluororesin Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: S (Sintered Metal, Stainless Steel Material), Nominal Filtration Accuracy: 120 μm, Element Seal Material: T (Fluororesin)
Material: T (SCS14 Cover, SS 316 Case, Fluororesin Gasket/O-ring, Fluororesin Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: S (Sintered Metal, Stainless Steel Material), Nominal Filtration Accuracy: 120 μm, Element Seal Material: T (Fluororesin), Accessory: B (Bracket)