motor (S3) 200 W AC servo motor (S2) 200 to 230 VAC 50/60 Hz AC servo motor (S4) 400 W AC servo motor (S3) Power supply voltage AC servo motor (S6) 100 W AC servo motor (S4) 1 2 100 to 120 VAC, 50/60 Hz 200 to 230 VAC, 50/60 Hz Absolute AC servo motor (S7) 200 W AC servo motor (S6) 100 to 120 VAC 50/60 Hz AC servo motor (S8) 400 W AC servo motor (S7) Pulse input type (For absolute encoder
20 20 0.15MPa 0.15MPa 0.15MPa 10 10 10 0.2MPa 0.2MPa 0.2MPa 100 200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
I I I 3.886 4.661 5.436 6.2t1 Table 6.19 Theoretical Air Consumption ot double acting cylinders from 20 to 100 mm dia, in liters per 100 mm stroke Example 1.
I I I 3.886 4.661 5.436 6.2t1 Table 6.19 Theoretical Air Consumption ot double acting cylinders from 20 to 100 mm dia, in liters per 100 mm stroke Example 1.
to 500 100 to 500 200 to 600 Work load [kg]*1 Horizontal 12 25 30 20 45 50 25 55 65 Vertical 0.5 7.5 15 4 10 20 2 2 23 In-line Stroke range Up to 500 20 to 1100 12 to 750 6 to 400 24 to 1200 16 to 800 8 to 400 30 to 1200 20 to 850 10 to 300 Speed*1 [mm/s] 501 to 600 30 to 1200 20 to 850 10 to 300 Actuator specifications Parallel Stroke range Up to 500 20 to 900 12 to 600 6 to 300 24 to 800
) Max. 5.6 (142.2) (When selecting option code P) 0 20 40 60 80 100 120 140 160 180 200 Flow rate (slpm, N2) AZ1000 100 psig (0.69 MPa) 40 psig (0.28 MPa) Inlet pressure: 80 psig (0.55 MPa) 20 psig (0.14 MPa) 1.5 (38.1) 50 0.34 2.25 (57.2) 40 0.28 Delivery pressure (MPa) Delivery pressure (psig) 30 0.21 0.69 (17.5) 20 0.14 2.00 (50.8) 10 0.07 A 0 0.00 0.88 (22.4) 0 20 40 60 80 Flow rate (
Load rate: 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ5140-01 Cylinder is in extending.
3-Color Display Digital Flow Switch for Large Flow RoHS IP65 Applicable fluid Air, N2 Flow range: Max. 12000 L/min Flow ratio*1 100:1 *1 The flow ratio is 20 : 1 for the current model (PF2A7H/Large flow type).
(4) v = 150 mm/s or less v = 200 mm/s or less Graph (7) Graph (8) 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 MGF100 10 MGF100 MGF100 50 40 50 40 MGF63 Load weight m0 (kg) Load weight m0 (kg) MGF63 Load weight m (kg) Load weight m (kg) 30 30 MGF63 10 20 20 MGF63 5 10 10 MGF40 5 4 3 5 4 3 MGF40 MGF40 MGF40 5 MGF40 2 2 3 5 2 1 1 10 20 30 40 50 100 200 300 400 10 20 30 40 50 100 200
Double acting, Single rod Double acting, Double rod CE1 50 63 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 CE2 80 100 ML2B C J G5-S CHQB CHQWB CV MVGQ CC For details, refer to the catalog CAT. E111.
Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 40 50 63 80 100 125 140 160 180 200 Average speed Series (mm/s) 1000 Perpendicular, upward actuation 900 800 700 600 500 400 300 200 100 Horizontal actuation VQ7-6-FG-S-A02 0 1000 900 800 700 600 500 400 300 200 100 0 Courtesy of Steven Engineering, Inc.-230
Additional weight with air cushion 0.01 0.01 0.02 0.02 Additional weight for long stroke 0.01 0.01 0.02 0.03 No. of auto switches mounted Auto switch model Calculation: (Example) CLG1LA20-100 (Foot, 20, 100 st) Basic weight Additional weight Air cylinder stroke Additional weight of air cushion 0.72 + 0.05 x 100/50 + 0.01 = 0.83 kg 1 2 D-B5/B64 D-C7/C80 D-H7 D-G5/K5 0.72 0.05/50 st 100
PS 24 27 GR-S-010(10g 14 30 1216 30 1216 30 2025 100 3263 100 15 17-2.
Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB, CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Average speed Series (mm/s) VQC 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SQ VQ0149-C4 VQ0 VQ4 800 700 600 500 400 300 200
50 100 40 20 R: 0.35, H: 0.42 R: 7, H: 7.5 25 R: 0.56, H: 0.65 R: 7, H: 7.5 100 32 Total load weight (kg) 32 0.91 7.5 100 25 40 1.8 8.7 10 50 3.4 11.8 100 20 High kinetic energy generated by large loads and high speed operations can be absorbed by compressing air at the stroke end thus preventing shock and vibration being transmitted to the machine.
DATA OUT 1 2 3 SET 1 2 SET MONOSASHI-KUN AC100V OUT1 COM OUT2 COM COM OUT3 Series Guide Series CE1 Bore size (mm) Available stroke range Standard stroke (mm) Series CEP1 Standard stroke (mm) Bore size (mm) 12 equiv. 250 400 500 300 175 200 150 125 100 75 50 100 25 75 50 25 12 25 to 150 20 equiv. 20 25 to 300 32 25 to 400 40 25 to 600 50 25 to 600 63 25 to 600 CEU1 CEU5 Output transistor system
Burst pressure Min. bending radius (mm) 100 15 20 30 60 75 75 60 48 36 24 25 13 20 to +60C (Water: 0 to 40 C) (No freezing) Operating temp. Nylon 12 Material Precautions How to Order Be sure to read before handling.
, 25, 30, 35 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 Surge voltage suppressor Diode (Non-polar: Varistor) 32 1 Indicator light LED Note) The S and Z types of surge voltage suppressor have an internal circuit allowing voltage drop, so use within the following allowable voltage range
C 8 8 8.5 8.5 D 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 Mounting bolt M3 X 50l M3 X 60l M3 X 50l M3 X 60l M5 X 75l M5 X 85l M5 X 75l M5 X 85l M5 X 85l M5 X 95l M5 X 75l M5 X 85l M6 X 95l M6 X 130l M8 X 100l M8 X 130l MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20 MKB50-50 MKB63-20 MKB63-50 PTo attach and detach