Unrestricted Base mounted 300/50 SA Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 25 VX3 3/8" 47.5 28 H 21 24 23 29.5 1/2" VXA 50 29.5 1/2" VN 58.5 39 26 32 29 36 3/4" 60 LVC 36 3/4" 75 LVA M 25 1 49 36 46 39.5 44.5 1" 78.5 LVH Class 6 LVD Inch sizes (E) shows the reference of the inserted tubing from the end of the nut.
to 525 75 to 525 +0.75 to +5.25 V 0..20 mA 0 to 2100 0 to 2100 +0.00 to +21.00 mA 4..20 mA 300 to 2100 300 to 2100 +3.00 to +21.00 mA 1: Follow the methods below when assigning the user set upper and lower limit by E.O.
(Energized closed) Voltage 1 2 3 4 5 6 7 8 9 100V AC 50/60Hz 200V AC 50/60Hz 110V AC 50/60Hz 220V AC 50/60Hz 24V DC 12V DC 240V AC 50/60Hz 48V AC 50/60Hz Other (Contact SMC seprately) Options Standard F, G, L, T are available option. Refer to p.4.0-11 "Applicable Fluid Check List".
Fig. 12-1 EX245-DY1 EX245-DY1 EX245-DY1-37 75 No.EX##-OMY0006CN 12.2. Table 12-1 EX245-DY1 (W x L x H) mm 54 x 120 x 61 280 g , PBT 24 V DC 1.6 V 50 mA 4 x M125 A code 2 / , US2 30 V /1 0.5A /1 2 A 1 1 8 PNP 76 No.EX##-OMY0006CN 12.3. /SI IP65M12 M12,5 , Table 12-2 EX245-DY1 (TOP View) 1 N.C.() 2 2 DO ( n+1) 3 5 1 3 0 V (/) 4 DO ( n) 4 5 FE/ 12.4.
Lead wire length Nil 0.6 m Example) ZSE1-00-15CN-X129 ZS-20-5A-50 1 pc. 1 pc. 30 3 m 50 5 m 13-8-8 9 Ejector Valve Unit Series ZYY/ZYX How to Set the Pressure How to Use the Connector Hysteresis Hysteresis is the difference between the pressure at which the output signal turns ON and the pressure at which it turns OFF. It turns ON at the set pressure. 1.
535 1 5 10 20 50 1 5 10 20 50 16-11-13 10 For details about certified products conforming to international standards, visit us at www.smcworld.com.
JIS symbol Double acting Minimum Strokes for Auto Switch Mounting Stroke Long stroke (2) (mm) Max stroke (mm) Number of switches Bore size (mm) Standard stroke (1) (mm) Auto switch model 2 1 D-C7/C8 D-B5/B6 D-H7 D-G5/K5 25, 50, 75, 100, 125, 150, 200 201 to 350 20 15mm 10mm 301 to 400 25 301 to 450 32 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 15mm 1500 301 to 800 40 D-B59W 301 to 1200
Coil rated voltage VP7 1 2 3 4 5 6 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC VP4 VQ VQ4 Wiring Specifications VQZ The lead wires are connected to the valve as shown below. Connect each to the power supply side.
Series Variations Model Bearing Bore size Stroke [mm] Cushion Piston speed Port size Mounting direction JMGP 12 (10 x 2) 10, 20, 30, 50, 100 M3 x 0.5 16 (12 x 2) 20 (16 x 2) 20, 30, 50, 100, 150 M5 x 0.8 25 (20 x 2) 50 to 300 mm/s Top 32 (25 x 2) Rubber bumper on both ends Slide bearing Bottom 40 (32 x 2) 1/8 (Rc, NPT, G) 50 (40 x 2) Rear 25, 50, 100, 150, 200 63 (45 x 2) 80 (56 x 2) 50 to
V L4=50+T+X 50 SMC H H L L O O S S U U C C P P K K 8 U 57 (at knob locked) DIN rail part no.
Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.
(mm) Proper tightening torque (Nm) Cylinder stroke (mm) Model 5 10 15 20 25 30 40 50 6, 10 16 20, 25 32 M3 M4 M5 M6 1.08 10% 2.45 10% 5.10 10% 8.04 10% 22 (27) 25 (35) 28 (38) 31 (41) 34 (44) 37 (47) C(D)U6-D 36 (41) 40 (50) 44 (54) 48 (58) 52 (62) 56 (66) C(D)U10-D 50 (75) 56 (86) 62 (92) 68 (98) 74 (104) 80 (110) C(D)U16-D 95 (128) 106 (143) 117 (154) 128 (165) 139 (176) 150 (187)
53 20 32 43 48 52 57 61 66 70 75 79 83 16 40 69 75 81 87 93 99 105 111 117 123 1.0 12 50 127 137 147 157 167 177 187 197 207 63 180 190 200 210 220 230 240 250 260 0.4 80 329 344 359 374 389 404 419 433 448 0 10 20 30 40 50 100 545 565 586 607 628 649 670 690 711 Cylinder stroke [mm] Weight [g] Without Magnet for Auto Switch [g] With Magnet for Auto Switch Bore size [mm] Cylinder stroke
0.8 8 OUT1 80 mA 65 180 45 104 79 65 Rc11/2, NPT11/2, G11/2 Rc2, NPT2, G2 46 M6 x 1 9 Load Black 0 V or 75 220 55 114 89 75 56 M6 x 1 9 50 msec 50 msec PF2A7H-(-M) 68 69 Analog output 1 to 5 VDC 4 to 20 mADC 20 5 Analog output [V] Analog output [V] 1 4 Min. measured flow rate value Max. measured flow rate value Real-time flow rate [l/min] Max. measured flow rate value Real-time flow rate
-06 3/4 75 172.5 20 70 14 50 54 25 8.5 10.5 70 2.3 73 198 Float type Courtesy of Steven Engineering, Inc. !
Load Weight Allowable Moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
B 0.2 A 0.2 Bore size [mm] A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 7.
Note 7) The display unit is comformed to CE mark. 4 Series PF2A Flow Characteristics (Pressure Loss) PF2A710,510 PF2A750,550 PF2A711,511 3.0 1.0 10 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 2.5 0.8 8 2.0 6 0.6 1.5 0.4 4 1.0 0.2 2 0.5 Flow rate (l/min) 0 100 10 25 50 75 5 2.5 7.5 0 5 10 15 20 25 30 40 35 45 50 0 1 10 Flow rate (l/min) Flow rate (l/min) PF2A721,521 PF2A751,551