Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.
Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.
Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), MFLD, BLOCK, VALVE, SS5V1 MANIFOLD SV1000, U1, SS5V1 BUILT IN FITTING 1/4), .03744 lb
L-type block (75) (50) W R P Q Port size Weight (kg) d K W Y AE (mm) (75) (50) W J W (mm) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 47 47 47 50 50 50 50 50 70 70 70 85 85 85 105 105 9 9 9 9 9 9 9 9 62 62 62 65 65 65 65 65 3.5 3.5 3.5 6.2 6.2 6.1 11.9 11.9 Port size Weight (kg) E J P Q Port size Weight (kg) E 69
-1A-C6 $24.05 This product is obsolete.
Model VV3Z2-20 VV3Z2-30 VV3Z2-50 -S50 Part no.
40 55 9 18 7 50 65 AC40A-06-D 3/4 1/8 155.2 149.1 93 38.4 77.6 110 35.5 50 40 55 9 18 7 50 65 AC50A-D 3/4, 1 1/8 191.2 234.1 155 98.1 110 45 70 50 70 11 20 8 60 80 AC60A-D 1 1/8 196.2 234.1 155 98.1 110 45 70 50 70 11 20 8 60 80 Model Optional specifications Semi-standard specifications PC/PA bowl Metal bowl Metal bowl with level gauge Square embedded type pressure gauge Round type
143 28 50 110 14 7 35 41 55 28.5 64 13 184 7 4 71 0 146 31 50 110 7 14 35 55 41 66 30.5 7 4 71 10 3.5 187 183 36 75 145 9 18 72.5 40 50 35 74 12 222 9 4 88 3.5 185 36 75 155 9 18 40 77.5 50 35 12 74 224 9 4.6 88 3 264 43 20 186 20 11 50 70 93 44.5 84 16 303 11 6.4 115 3.3 277 43 20 191 11 20 50 98 70 84 44.5 11 6.4 117.5 16 3.3 316 280 46 20 196 11 20 98 50 70 44.5 84 13 319 11 6.4
50 68.5 76.5 145 86.5 155 50 50 68.5 13 (port B) 13 (port A) 13 (port B) 13 (port A) Manual override Manual override B A B A B B 38 50 62 38 50 62 Indicator light R1 P R2 R1 R2 Indicator light 2-6.5 Mounting hole 2-6.5 Mounting hole 42.5 42.5 42.5 42.5 G1/2 (cable 6.8 to 10) G1/2 (cable 6.8 to 10) 125.5 137.5 125.5 137.5 37 93 37 93 25 (port X) 25 (port X) 5 3 3 5 22 22 14 14 1 1 2-Rc3/8
Abnk pbr .8dy DXT201-15-1A Side ported NW325.41-O-O Applicau Yelv .
Abnk pbr .8dy DXT201-15-1A Side ported NW325.41-O-O Applicau Yelv .
Material 16 25 40 50 Standard AS568-122V AS568-129V AS568-140V AS568-231V External seal e AS568-122 AS568-129 AS568-140 AS568-231 XLAQ XLDQ Special Standard B2401-V15V B2401-V24V B2401-P42V AS568-227V Valve seal w B2401-V15 B2401-V24 B2401-P42 AS568-227 Special S valve seal assembly r XLD40-2-9-1A XLD50-2-9-1A Standard XLD50-2-9-1A XLDQ XLD40-2-9-1A Special Note 1) Add a suffix for the
For a 10 orifice (VXS23/Port size 1/4), P 0.05 MPa The optimum size for a pressure differential of P 0.2 MPa and a flow of 50 L/min will be the VXS23 (10 orifice, port size 3/8). 500 400 VXS26 25 Cv = 12 300 VXS25 20 Cv = 9.2 200 VXS24 15 Cv = 5.3 Flow rate Q [L/min] 100 VXS23 Port size 3/8 10 Cv = 2.8 VXS23 Port size 1/4 10 Cv = 2.4 50 40 30 25 20 10 0.01 0.02 0.03 0.04 0.05 0.1 0.2 0.3
The standard output pressur for moving part air logic is 50 PSIG (3.44 Bar). The 25 PSIG pllot pr$sure required to shlft this valve gives approximately th samo response lo shitl and to return when the pllot pressure applled is 50 PSIG (3.44 Bar). The minimum volume of iho pilol chamber and the small swept volume disptaced by the short.slroke apool also aid in tast response.
(Example) 2000mm lead wire length Coil 6 10 15 20 25 30 50 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm Black(--) Non polarity type ( U) <12V,24VDC only> For DC SYJ3120-5LO-M3 SY100-30-4A-20 For AC SYJ3120-1LO-M3 SY100-30-1A-20 (+)(--) Coil (+)(--) Correctly connect the lead wires to + (positive) and (negative) indications on the connector.
Equipment Type of actuation 53-SY5000 53-SY7000 53-SY9000 Uo (or Voc) lo (or Isc) Po Co (or Ca) Lo (La) Ui li Pi Ci + Ccable Li + Lcable 2-position single 26 or less 38 or less 50 or less 2-position double 22 or less 30 or less 50 or less 3-position 38 or less 56 or less If the cable capacitance and inductance are unknown, use the following values: Ccable = 60 pF/ft., Lcable = 0.2 H/ft.
Blanking plate assembly (Manifold option) Part no: V100-77-1A Place notch mark on the blanking plate to 2 port side when assembling.
ISA2 Note) 5 With LED light (24 VDC, Red) 50 20 to 50 l/min Note) 6 With LED light (24 VDC, Green) IS Note) LED light is available for 5, 6, 7, 8 (with terminal box for 24 VDC).