Note 3) Window comparator mode Since hysteresis is 3 digits, separate P1 and P2 by 7 digits or more. 1 digit is the minimum setting unit (refer to the table above).
Note 3) Window comparator mode Since hysteresis is 3 digits, separate P1 and P2 by 7 digits or more. 1 digit is the minimum setting unit (refer to the table above). 20 For Air Digital Flow Switch Series PFA How to order PFW3 0 0 A Remote Type Display Unit Unit specification Flow rate range Nil M With unit switching function Fixed SI unit Note) 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 1 0
Note ) 2 position double and 3 position cannot be mounted. 40.6 3(R2) 5(R1) P1 Po 1(P) Circuit diagram Plug-in type Plug lead type SUP blocking plate VVQ5000-16A-1 EXH blocking plate VVQ5000-16A-2 18.5 20.2 When 2 or more different pressures are supplied to one manifold, blocking plates are installed between stations under different pressures. 28.8 44.6 R P R R P R R P R SUP/EXH passages
Item Classification pD(Torrcm) /D (Knudsen number) >0.5 <0.01 Viscous flow 0.5 to 0.015 0.01 to 0.3 Intermediate flow <0.015 >0.3 Molecular flow 8 Exhaust time (low/medium vacuum) 4 5 1 2 3 4 1 2 3 The time (gt) required to exhaust a chamber at low vacuum with volume V (l), from pressure P1 to P2, using a pump with pumping speed S (l/sec) is gt=2.3(V/S)log(P1/P2).
Q=14.2Cv 10.2 P l/min G Formula based on effective area (Smm) Q=0.8S 10.2P l/min G Other : Flow rate (l/min) : Pressure differential (P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm) : Cv factor : Fluid specific gravity (water = 1) Q P P1 P2 S Cv G 1. Materials FKM: Fluoro rubber Trade names: Viton, Dai-el, etc. 2.
Pressure Momentary change P1 P2 Set value Anti-chattering function Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the primary pressure.
CKZN SLIM LINE CLAMP CYLINDER, P1, 63MM CKZN SLIM LINE CLAMP CYL, .07612 lb
When P1 (inlet pressure) becomes lower than P2 (outlet pressure), the check valve opens and the pressure in the diaphragm chamber is discharged to the P1 side.
This allows the outlet pressure to flow back rapidly to the inlet side due to the mechanism that opens the main valve.
The AR20K-B to AR60K-B and the AR20K-D to AR40K-D series are regulators with a backflow function.
When P1 (inlet pressure) becomes lower than P2 (outlet pressure), the check valve opens and the pressure in the diaphragm chamber is discharged to the P1 side.
This allows the outlet pressure to flow back rapidly to the inlet side due to the mechanism that opens the main valve.
The AR20K-B to AR60K-B and the AR20K-D to AR40K-D are regulators with a backflow function.
Part Number Description: 63MM MY1B PARTS Product Line: A Product Line Description: ACTUATOR Family Code: 464 Family Description: MY1B GUIDED CYLINDER Class Code: P1 Click here to report information errorImage shown may not match exact part number, 63MM MY1B PARTS, ACTUATOR, MY1B GUIDED CYLINDER, P1
Light gray (GR2) KQG2 Neon pink (P1) Solid purple (PU1) KG Clear purple (PU2) Caution Solid red (R1) KFG2 Clear red (R2) 1. Applicable for general industrial water. Please consult with SMC if using for the other kind of fluid. Also, the surge voltage pressure must be under the maximum operating pressure.
, CLA/CLA2 TIE-ROD CYLINDER, P1, 63MM CLA PART, .00000 lb
P1, 63MM CQ2 PART, 1.21000 lb
CYL, P1, 63MM CY3B PART, 1.39084 lb
Vs: Power supply 24VDC 12 to 15VDC One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2. S1 S2 Preset pressure OFF OFF P1 ON OFF P2 OFF ON P3 ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to 0MPa.
Pressure Momentary change P1 P2 Set value Anti-chattering function Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the primary pressure.
Mist generation pressure differential (MPa) IC EX: How to obtain the mist generating pressure differential if the flow rate obtaine in 1. above is 35 m3/min and the line pressure (inlet pressure P1) is 0.7 MPa: Extend horizontally from the point at which the flow rate is 35 m3/min to obtain the point that intersects with P1 = 0.7 MPa.
Step 20 Step 5 Analog output 4-20 mA 0-10 VDC P4 Set pressure P3 PPA P2 AL P1 0 1023 Digital input data Time Digital signal Digital signal Analog signal Analog signal Analog signal Analog signal Controller Actuator Electro-pneumatic regulator Actuator Electro-pneumatic regulator Controller PLC PWR PWR ERR ERR 1bit 2 bit . . . . 10 bit 010 VDC 420 mA 010 VDC 420 mA Series ITV Series ITV Series
Primary pressure normal Set value P1 P2 Time ON Switch output 1, 2 OFF Time [ ] Switch output response time when auto shift is input. 5 ms or more 10 ms or less Hi Auto shift input Lo 3 types of piping Different piping methods are possible to accommodate the installation location.
Vacuum pressure: P1 Conversely, the size of the ejector or the size of the switching valve of the vacuum pump system can be obtained from the adsorption response time.