Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: Voltage, Pipe Port Type: Female Thread, Plumbing Thread Type: M, Plumbing Thread Nominal: M5x0.8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range(%): 35~85, Number

Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: Voltage, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [NPT] NPT, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature Range(°C): -5~50, Operating Humidity

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: -, Adapter: -, Calibration Certificate: -

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: -, Calibration Certificate: -

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: R1/8 Piping Adapter, Side Ported, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certificate: w/Certificate

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certificate: w/Certificate

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certificate: w/Certificate

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: -, Adapter: -, Calibration Certificate: -

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: -, Calibration Certificate: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUM SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER NO SIZE RATING, .03306 lb, ModelRated pressure rangeSet pressure range/Pressure display rangeWithstand pressureMinimum unit settingFluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputDisplayDisplay

L+ power supply C/Q signal P24 power supply Enable Diagnostics is generated. 2 Short Circuit Monitor Unit Disable Diagnostics is not generated. All outputs are turned OFF The process data status is Clear, PD Out valid valid. All outputs hold the values Set the IO-Link communication process data output when the EtherCAT communication error is occurred. of the last received process data.

L+ power supply C/Q signal P24 power supply Enable Diagnostics is generated. 3 Short Circuit Monitor Disable Diagnostics is not generated. All outputs are turned OFF while maintaining the process data output valid. Clear/ PD Out valid Output setting during Communication error (IO-Link) 3 Set the IO-Link communication process data output when the Fieldbus communication is in error.

C PE port Use when supply pressure for vacuum release which pressure is different from the ejector supply pressure is requested. With individual release pressure supply (PD) port type Note 21) D PD port Note 19) When more than one option is selected, list the option symbols in an alphabetical order.

3 Ejector assembly ZK2 EJ A W 10 Nozzle nominal size 07 0.7 10 1.0 12 1.2 15 1.5 Bellows type with groove Flat type with groove 257 ZHP Series Dimensions 30 N 70 Silencer In the case of Flat type P 16.6 EXH. 24.7 P F E D C A PD port 3 6.2 K M Female thread mounting M Male thread mounting Unlocked: 32.2 PD port 2 Locked Unlocked J PD port 1 G H P port L E F 6.2 10 7.8 6.2 Lock screw 14.4 1.4

Positioning Mode: Minimum actuator travel distance of 1[m]. 28 - Recommended Parameter Values [LEY] LEY25/LEYG25 LEY25D/LEYG25D LEY32/LEYG32 LEY32D/LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para. No Initial value Recommended value Number of command input pulses per revolution *3. PA05 100 100 Electronic gear numerator *3.

L+ power supply C/Q signal Enable Generate diagnostics 1 Short Circuit Unit Monitor Disable No diagnostics P24 power supply All outputs are turned OFF and process data outputs remain valid Clear/ PD Out valid Output setting under PROFINET communication fault (IO-Link) 1 Setting for IO-Link output process data behaviour when PROFINET communication errors are detected.

Refer to "LECSC2-T Operation Manual (Simplified Edition)", section 5.7 for how to set the Point table. -30- Recommended Parameter Values [LEY] LEY25/LEYG25 LEY25D/ LEYG25D LEY32/LEYG32 LEY32D/ LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para.

Please change the parameter in the initial setting. *3 The minimum unit of the travel distance of the actuator should be 1 [m]. -27- Recommended Parameter Values [LEY] LEY25/LEYG25 LEY25D/ LEYG25D LEY32/LEYG32 LEY32D/ LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para.

ZSE10/ISE10 compact, digital pressure switch has been reduced in height by approximately 50% when compared to the I/ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions.  VACUUM SWITCH, ZSE50-80. Low Profile Dig Pres Switch. 63.00000 lb.