ASSY KIT-5 STA. Product Line: V Product Line Description: VALVE Family Code: 277 Family Description: VS4 CLASS 3) SOL 4/5 PORT Class Code: 22 Part Code: 2 Reference Code: K Click here to report information errorImage shown may not match exact part number
Please contact us for the latest version.sales@ocaire.com, VQD1000-VCL-02-5, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 21, VQD1151 NO SIZE RATING, 0.83775 lb
Part Number Description: MFLD JCT COVER 5-STA Product Line: V Product Line Description: VALVE Family Code: 251 Family Description: VFS2000 SOL VALVE 4/5 PORT Class Code: 22 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
ASSY KIT-5 STA. Product Line: V Product Line Description: VALVE Family Code: 273 Family Description: VS4 CLASS 1) SOL 4/5 PORT Class Code: 22 Part Code: 2 Reference Code: K Click here to report information errorImage shown may not match exact part number
ASSY KIT-5 STA. Product Line: V Product Line Description: VALVE Family Code: 273 Family Description: VS4 CLASS 1) SOL 4/5 PORT Class Code: 22 Part Code: 2 Reference Code: K Click here to report information errorImage shown may not match exact part number
Part Number Description: COND CVR 5-STA UNIT Product Line: V Product Line Description: VALVE Family Code: 254 Family Description: VFS5000 SOL VALVE 4/5 PORT Class Code: 22 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
Part Number Description: NVFS 5-STA WIRE ASSY' Product Line: V Product Line Description: VALVE Family Code: 254 Family Description: VFS5000 SOL VALVE 4/5 PORT Class Code: 21 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
CVR 5-STA UNIT Product Line: V Product Line Description: VALVE Family Code: 252 Family Description: VFS3000 SOL VALVE 4/5 PORT Class Code: 22 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
4/5 PORT SOLENOID VALVE. 5 STA MFLD & VALVE ASSY. 1.10522 lb. VVD.
SHCS, 5/16-18X5/8. ACTUATOR. NCQ2 NO SIZE RATING PART. .00000 lb. 21.
(SI unit side) Valve manifold Output No. 1 3 5 7 9 17 29 31 Solenoid on side B Accessories Bit No. 1 3 5 7 1 1 5 7 Replacement of the SI unit Remove the M3 hexagon screw from the SI unit and release the SI unit from the valve manifold. Replace the SI unit.
Fieldbus system Operation Manual 5 (5)Fix the manifold by tightening the DIN rail fixing screws of the EX600-ZMA2. (M4 x 20) Tightening torque: 0.7 to 0.8 Nm. The tightening torque at the valve side depends on the valve type. Refer to the operation manual of the corresponding valve manifold.
Tighten the screws with the specified tightening torque. (0.6 Nm) Solenoid on side B Output No. 1 3 5 7 9 17 29 31 Technical documentation giving detailed accessories information can be found on the SMC website (URL http://www.smcworld.com). When conformity to UL is necessary the SI unit must be used with a UL1310 Class 2 power supply. 1 3 5 7 1 1 5 7 Bit No.
Hysteresis 6 Red CH3_OUT1 5 Grey CH2_OUT1 4 White CH1_OUT2 3 Black CH1_OUT1 2 Blue DC(-) ON OFF High pressure: For Compound/Positive High vacuum: For vacuum Displays in turn LCD display (Orange) Displays the current status of pressure, setting mode, selected indication unit and error code.
Press the SET button between 3 and 5 sec. Other parameter settings Press the SET button once.
Hysteresis (H_1) Window comparator mode : For vacuum: High vacuum ON OFF 5. Auto shift compensation value setting (PSE3 2(T)/3 5(T) models only) [C_5] and the Auto shift compensated value are displayed in turn. Check the corrected value, then press the button. The pressure settings are completed, and the controller will return to measurement mode.
If a pump is operated by super dry air and N2 gas, etc., the deterioration of the gaskets inside the switching valve will be accelerated and may result in substantially shortening the life span of the product. 5. Operating environment Warning 1.
Numeric data Read or written data with 5 digits regardless of its type. Minus data: (symbol for minus) is displayed at the 1st digit Position of decimal point: Not included in 5 digit data. Ex) The 5 digit numeric data means Ex.
XLC-16 XLC-25 XLC-40 XLC-50-1 XLC-63-1 XLC-80-1 XLC-100-1 XLC-160-1 16 25 40 50 63 80 100 160 560(5150) -5 Pa (abs) 110 l/s 1 5 14 45 80 160 200 300 800 10 (FKM) 1.310 Pam 3/S -11 (FKM) 1.310 KF(NW) KF(NW)K(DN) SUS316LSUS304FKM() 2 MPa (G) 0.30.6 0.40.6 cm 3 3 0.5MPa 38 91 430 280 500 1000 2300 3700 M5 Rc 1/8 Rc1/4 kg 0.28 0.46 1.1 1.4 2.3 4.0 8.7 14.5 1) 2) Y-VAC2 3) 1 7 XL-OMV0002