tank New New 20 9.2 4 AV2000-A Current model 30 13.1 7.4 Up to 50% shorter 40 19.2 12.2 50 (Port size 3/4) 34.8 22.6 AV2000-A New New Fill time 50 (Port size 1") 41.3 24.4 Current model For 1(P) R 2(A) Improved adjustability at low speed air supply Needle Valve Flow Rate Characteristics Inlet pressure: 0.5 MPa 400 Air flow rate [L/min (ANR)] 350 Current model 300 250 200 New New AV2000-A 150

End Plate Model EX245-EA2-1 EX245-EA2-2 Bracket Yes No Weight 200 g 150 g EX245-EA24 EX245 Series Dimensions SI Unit End Plate EX245-SPN1 EX245-EA2-1 120 6.5 14 22.1 28.6 6.6 5.6 98.8 148.5 133.5 61.5 1.6 6 85 10 EX245-EA2-2 37 18 120 14 61.5 44 50 130 23 35 Digital Input Module Digital Output Module EX245-DY1 EX245-DX1 22 22 27 13.5 61 120 120 81 27 54 54 61 5 Fieldbus System: For Input/

Hopping Spread Spectrum (FHSS) Frequency 2.4 GHz (2403 to 2481 MHz) Wireless communication Number of frequency channels 79 ch (Bandwidth: 1.0 MHz) Communication speed 250 kbps Communication distance 10 m (Depending on the operating environment) Radio Law certificate Japanese radio law (Japan), RE (EU*2), FCC (USA) For control/input (US1) Power supply voltage 24 VDC 10% Current consumption 150

Function Series AR20K-B to AR60K-B Flow-rate Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa AR10-A M5 AR20(K)-B Rc1/4 AR25(K)-B Rc3/8 AC AF+AR+AL AW+AL AF+AR AF+AFM+AR AW+AFM AF Attachment AFM / AFD AR AL AW 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 0 00 25 50 75 100 125 150

Indoor Outdoor Temperature control accuracy 0.01 to 0.03C Users equipment 1 Temperature sensor Users equipment 2 Heat source Users equipment 3 Thermo-chiller for facility water circuit HRSH Series HRS100/150 Series Water-cooled thermo-con HECR-W If the external temperature sensor is installed directly on the heat source, the learning control function may not work properly due to a large heat

It is particularly impossible to use liquid including metallic powder such as iron powder. pH (at 25C) 6.5 to 8.2 Electric conductivity (25C) [S/cm] 100*1 to 800*1 Chloride ion (Cl) [mg/L] 200 or less Sulfuric acid ion (SO42) [mg/L] 200 or less Standard item Acid consumption amount (at pH4.8) [mg/L] 100 or less Total hardness [mg/L] 200 or less Calcium hardness (CaCO3) [mg/L] 150

Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40

0.1 B L H G Effective thread depth J 2-Port size D I NB NB T N K W N S + Stroke F F NA R ZZ + Stroke 43 35 29 22 20.5 27.8 D Model Port size K NN B L MM x J N NA H 16 15 10 I 46 36 30 NB 19 17 17 T S 11 9 8 G ZZ 10 8 8 R 60 50 50 W 16 16 13 F 40 40 30 X 12-REA40 12-REA32 12-REA25 Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 70 60 46 M26 x 1.5 M26 x 1.5 M32 x 2.0 21 17 15 50 40 34 19 15 13 150

ON: 5 or less, OFF: 4 or less Response time (DC) ms Note 1) 20 Max. operating frequency (Hz) Manual override Non-locking push type, push-turn locking slotted type Not required Lubrication Unrestricted Mounting position 150/30 Impact / vibration resistance (m/s2) Note 2) Dust tight Enclosure Note 1) Based on dynamic performance test, JIS B 8374-1981 (Standard type :Coil temperature 20C, at

operated poppet valve Air/Inert gas 0.7 MPa 0 MPa/101.2 kPa ON: 4 ms 1, OFF: 2 ms 1 10 to 50C Note 2) Valve specifications Electrical specification Minimum operating pressure / Vacuum Response time Note 1) L plug connector Base mounted L plug connector Body ported Ambient and fluid temperature Lubrication Manual override Impact / Vibration resistance Note 3) Not required Non-locking push type 150

Representative values) Working Principle: AL10 Type AL10 M5 AL40-06 Rc 3/4 Needle fully opened 0.1 Open 1.5 turn Open 1.0 turn Open 2.0 turn Open 0.5 turn 0.1 P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.7 MPa Pressure drop (MPa) Pressure drop (MPa) 0.08 0.08 Needle Section AA P1 = 0.1 MPa 0.06 0.06 0.04 0.04 0.02 0.02 Conditions: P1 = 0.5 MPa Needle: One side fully opened 0 0 2000 4000 6000 8000 0 0 50 100 150

10, ALDU900-12 to 20 Float switch mounting position Mounting thread M12 R 3.2 S 40 Q IN P M N M L A B C E E F G K J (Bracket mounting dimensions) H D S Bracket (Option) Panel (Option) 6 x 17 A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 289 291.2 453 453 476 24.5 13.6 51 45.5 14.5 69.5 78.2 89 94.5 102.5 4 3 55.5 344 487 145 90 150

AMV15 SP ZCUK 0.015 Inlet pressure (MPa) AMJ AFJ 0.01 AMV AMV AMV15 AMV160 AMV75 AMV37 AMV6 AMV3 ZH -X185 0.005 Related Products 0 100 200 500 1,000 2,000 5,000 10,000 20,000 Flow rate (L/min [ANR]) Dimensions AMV3, 6, 15, 37 AMV 75, 160 B Exhaust Exhaust A A B Port size IN IN C E 8 x d Flange part Model Port size A 231 305 410 710 562 860 B 123 153 210 210 500 500 C 80.7 105.3 d 19 19 E 150

Lockable by installing the AP PL210 to the actuation port of air operated valve (only available for N.C. with actuation port connection NPT 1/8 inch) Prevent accidental valve opening by manually shutting off actuation pressure Lockable only in the closed position Accept standard pad lock with 1/4 inch shackle Actuation port connection:10-32 UNF thread Actuation port pressure rating: Maximum 150

Lockable by installing the AP PL210 to the actuation port of air operated valve (only available for N.C. with actuation port connection NPT 1/8 inch) Prevent accidental valve opening by manually shutting off actuation pressure Lockable only in the closed position Accept standard pad lock with 1/4 inch shackle Actuation port connection:10-32 UNF thread Actuation port pressure rating: Maximum 150

(Individual IN) IN (Common IN) SRP SRF Symbol Model Dimensions ITV C 34 43 D 21 28 E 18 27 F 56 70 G 16 20 H 9 11.5 J 18 24 K 19 28 M 52 66 P 9 11.5 Q 11.5 16.5 R 4.8 4.8 A 4.5 4.5 B 25 34.5 ARM1000 ARM2000 IC ITVH Dimensions by the Number of Stations Manifold stations (n) ITVX Model Symbol 1 36 27 48 39 2 55 46 76 67 3 74 65 104 95 4 93 84 132 123 5 112 103 160 151 6 131 122 188 179 7 150

MPa Flow rate 20 L/min (ANR) Condition: Inlet pressure 0.7 MPa Flow Characteristics (Representative values) Pressure Characteristics (Representative values) ARP20(K) ARP20(K) Rc 1/4 0.50 0.25 0.45 ARJ 0.40 AR425 to 935 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 ARX 0.20 0.25 AMR 0.20 ARM 0.15 0.10 ARP ARP 0.05 IR 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150

Flow rate 20 L/min (ANR) Condition: Inlet pressure 0.7 MPa Flow Rate Characteristics (Representative values) Pressure Characteristics (Representative values) ARP20(K) ARP20(K) Rc 1/4 0.50 0.25 0.45 ARJ 0.40 AR425 to 935 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 ARX 0.20 0.25 AMR 0.20 ARM 0.15 0.10 ARP ARP 0.05 IR-A 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150

Inlet pressure 0.5 MPa Outlet pressure 0.2 MPa Flow rate 20 l/min (ANR) Condition: Inlet pressure 0.7 MPa Flow Characteristics (Representative values) Pressure Characteristics (Representative values) ARP20(K) ARP20(K) Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150

A digital pressure gauge is recommended for such situation or as deemed necessary. 451 AR10-A to AR40-A Series Flow Rate Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa AR10-A M5 AR20-A Rc1/4 0.6 0.6 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 0 25 50 75 100 125 150 0 200 400 600 800 Flow rate L/min (ANR) Flow rate L/min