SMC Corporation of America
Elite Part Number Search
Search Results "CBA2B100-700-RL"

Double acting, single rod, standard type, Bore sizes (mm): 40, 50, 63, 80, 100, Standard strokes (mm): 25 to 700, Maximum operating pressure: 1.0MPa, Auto switch capable, 80MM CA1 DOUBLE-ACTING, ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, RD, 80MM CA1 DOUBLE-ACTING, 10.47195 lb

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

VP300/500/700 series solenoid valve, offers high flow capacity and?reduced power consumption (1.55W standard, 0.55W with power saving circuit).? The?series may be?used as either a?selector valve, or a divider valve.? It is vacuum applicable up to ?101.2kPa.? Series VP3145/3165/3185 is a large size, 3 port solenoid valve with a rubber seal.?

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

/s2] Note 4)Actuation typeGuide typeOperating temperature range [nC]Operating humidity range[%RH]Motor output/SizeMotor typeEncoderPowerconsumption [W] Note 5)Standby power consumption when operating [W] Note 6)Max. instantaneous power consumption [W] Note 7)Type Note 8)Holding force [N]Power consumption at 20nC [W] Note 9)Rated voltage [V]Stroke rangeLEFS32S3100, 200, 300, 400500, 600, 700

/s2] Note 4)Actuation typeGuide typeOperating temperature range [nC]Operating humidity range[%RH]Motor output/SizeMotor typeEncoderPowerconsumption [W] Note 5)Standby power consumption when operating [W] Note 6)Max. instantaneous power consumption [W] Note 7)Type Note 8)Holding force [N]Power consumption at 20nC [W] Note 9)Rated voltage [V]Stroke rangeLEFS32S3100, 200, 300, 400500, 600, 700

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

pulse 0.05 l/pulse 0.5 l/pulse 1 l/pulse Accumulated pulse flow rate exchange value (Pulse width: 50 ms) Operating fluid temperature Linearity Repeatability Temperature characteristics Note 1) 0 to 50C 3% F.S. or less 5% F.S. or less 3% F.S. or less 2% F.S. or less 5% F.S. or less (0 to 50C, based on 25C) Current consumption (No load) Weight Note 2) 70 mA or less 80 mA or less 520 g 460 g 700

It an accurale speed control is requird or load lorces vary widely, 60-700/0 should not be exceeded -perhaps no more than soyo in vertical applications. Table 6.16 givs the Load Ratio for cylinders from 25 to 1OO mm dia. and various elevations and two triction coetficients tor rolling (0.01) and sliding steel parts (0.2).

Cushion angle With air cushion Rotation time (s/90) Rubber bumper Without cushion 0.25 x 100.2 to 0.7 10 0.39 x 100.2 to 0.7 15 0.12 0.2 to 1 40 0.025 20 0.25 0.2 to 1 40 0.048 30 0.40 0.2 to 1 40 0.081 40 ) Allowable kinetic energy with cushion Maximum energy absorption with optimal adjustment of cushion needle Weight Table (g) Standard weight Size 90 180 120 150 10 220 270 15 600 700

Nil S n Standard stroke Standard stroke (mm) 100, 150, 200, 250, 300 350, 400, 450, 500, 600, 700 Bore size (mm) Type of auto switch 15, 32 Nil Select auto switches from the table below.

High precision guide type CY1HT(2 axes) Fitted with 2 linear guides (2 axes) High precision guide type CY1H (1 axis) Ball bushing type CY1L Fitted with linear guide (1 axis) Ball bushings installed in guides Allowable moment Large Options Individual order made products 700 800 900 1000 XB6 XB9 XB11 XB13 XC18 XC24 XC57 X116 X132 X160 X168 X206 X210 X211 X322 X324 X431 Auto switch Shock absorber

Features 2 Series LJ1 Electric Actuator Series Variations Maximum work load (kg) Maximum speed (mm/sec) Positioning repeatability (mm) Stroke (mm) Motor output (W) Guide type Typical model Mounting position Series Feed screw 100 200 300 400 500 600 700 800 900 1000 1200 1500 Ground ball screw Lead 12mm 0.02 Horizontal Vertical 1) 600 10 Rolled ball screw Lead 12mm 50 0.05 0.1 500 Slide screw