Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Option 1: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (SI Unit Only), Option 2: R (w/Bracket)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: JT (OUT1: Analogue 1 to 5 V - OUT2: Analogue 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: G (Instantaneous Flow: gal/min, Accumulated Flow: gal.
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 04 (1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket)
Function: 1 (2 Position Single), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal
Size: 4 (Base Mounted), Pilot: 1 (External Pilot), Power Source, Command Signal: 24V, 1~5V, Port Size: 04 (1/2)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve: None; Stop Valve: None, Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Pad Diameter: ø16, Pad Type: B (Bellows), Pad Material: U (Urethane Rubber), Buffer Specifications: K (Non-rotating), Stroke: 10mm, Vacuum Inlet: 04 (ø4 Tubing, One-touch Fitting)
Stations: 4 Stations, Port Thread: T (NPTF), Exhaust Port: 04 (1/2), Exhaust Port & Silencer Location: L (Left Side)
Body Size: 40, Filter Type: D (Antibacterial Filter + Antibacterial Filter + Odor Removal Filter + Bacteria Removal Filter), Thread Type: F (G), Port Size: 04 (1/2), Flow Direction: R (Right to Left)
Body Size: 40, Filter Type: B (Antibacterial Filter + Antibacterial Filter + Bacteria Removal Filter), Thread Type: F (G), Port Size: 04 (1/2)
Filter Type: BFB (Antibacterial Filter, Nominal Filtration: 0.1μm; Antibacterial Activation Value of 4 or Above), Body Size: 40, Thread Type: Rc, Port Size: 04 (1/2)
Filter Type: BFD (Bacteria Removal Filter, Nominal Filtration: 0.01μm; Bacteria Capture Performance LRV ≥ 9), Body Size: 40, Thread Type: N (NPT), Port Size: 04 (1/2), Flow Direction: R (Flow Direction: Right to Left)
Body Size: 40, Filter Type: D (Antibacterial Filter + Antibacterial Filter + Odor Removal Filter + Bacteria Removal Filter), Thread Type: N (NPT), Port Size: 04 (1/2)
Filter Type: BFA (Antibacterial Filter, Nominal Filtration: 5μm; Antibacterial Activation Value of 4 or Above), Body Size: 40, Thread Type: N (NPT), Port Size: 04 (1/2)
Body Size: 40, Filter Type: D (Antibacterial Filter + Antibacterial Filter + Odor Removal Filter + Bacteria Removal Filter), Thread Type: Rc, Port Size: 04 (1/2)
Filter Type: BFC (Odor Removal Filter), Body Size: 40, Thread Type: N (NPT), Port Size: 04 (1/2)
Filter Type: BFD (Bacteria Removal Filter, Nominal Filtration: 0.01μm; Bacteria Capture Performance LRV ≥ 9), Body Size: 40, Thread Type: N (NPT), Port Size: 04 (1/2)
Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: None, Manual Override: A (Non-locking Push Extended Style), Port Specification: B (Bottom Ported), Port Size: 04 (1/2), Thread: T (NPTF)