Function: 1 (2 Position Single), Body Option: 30 (Body Ported/Common Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: F (G)
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: U (Light & Surge Suppressor Non-polar), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: F (G)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: E (Push-turn Locking Lever Style), Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: Rc, Option: F (Bracket)
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: LO (L-type Plug Connector w/o Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: F (G), Actuation Type: A (N.C.,
Series: 1 (VFA1000), Actuation: 2 (2 Position Double), Body: 20, A, B Port Size: 01 (1/8), Thread: T (NPTF), Bracket: F (w/Bracket), Pilot Port Direction: P (Lateral)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 7 (240 VAC, 50/60 Hz, Semi-Standard), Electrical Entry: G (300mm Lead Wire), Light_Surge Voltage Suppressor: S (with Surge Voltage Suppressor, Grommet Type Only), Port Size: 01 [1/8 (6A)], Thread Type: N (NPT), Bracket: F (with Bracket)
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 03 (Side, 3/8), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD6N (Serial Kit for PROFIBUS DP), End Plate: 2 (M12 Connector Power Supply, Max.
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: K (Operation Manual, Calibration Certificate)
psi, °F, Pressue Gauge: MPa/psi Dual Scale)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: Individual EXH, Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LN (L Plug Connector w/o Lead Wire), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: N (NPT), Bracket: F (Bracket)
Type: 332 (Body Ported), Valve Option: Standard Type, Rated Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: None, Port Size: 01 [Rc 1/8, (Base Mounted w/Sub-plate)], Thread: F (G)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8)
Body Type: T (Body Ported), Valve Option: E (Continuous Duty Type, Semi Standard), Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 2 (200 Vac, 50/60 Hz), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor, DIN Terminal Type Only), Port Size: 01 [1/8 (6A)], Thread Type: Rc, Bracket: F (with Bracket)
Size: 01(Size 26mm), Stations: 2 Stations, A, B Port: Side, 3/8, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: AS-i, 4 In/Out, 2 Power Supply Systems, End Plate: w/o SI Unit/End Plate, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: None, X Option: X1, CE Compliant: -
Size: 01(Size 26mm), Stations: 3 Stations, A, B Port: Side, 3/8, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: AS-i, 4 In/Out, 2 Power Supply Systems, End Plate: w/o SI Unit/End Plate, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: None, X Option: X1, CE Compliant: -
Size: 01(Size 26mm), Stations: 5 Stations, A, B Port: Side, 3/8, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: AS-i, 4 In/Out, 2 Power Supply Systems, End Plate: w/o SI Unit/End Plate, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: None, X Option: X1, CE Compliant: -
Size: 01(Size 26mm), Stations: 6 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: -COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 4 Stations, A, B Port: Side, 3/8, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: AS-i, 4 In/Out, 2 Power Supply Systems, End Plate: w/o SI Unit/End Plate, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: None, X Option: X1, CE Compliant: -
Size: 01(Size 26mm), Stations: 6 Stations, A, B Port: Side, 3/8, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: AS-i, 4 In/Out, 2 Power Supply Systems, End Plate: w/o SI Unit/End Plate, SI Unit COM: -COM, Number of Input Blocks: w/o Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: None, X Option: X1, CE Compliant: -