From a point indicating 500 mm/s on the axis of abscissas, extend a line upward and find a point where it intersects with a line for the 63 mm bore size. Extend a line from the intersection to the left and find a load mass 80 kg.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
B A B A B A B A B A HS HS HS HS RE A B 20 20 27 27.5 24.5 72 62 15 17.5 12 16 10.5 19.5 14 14.5 9 8.5 20.5 14 25 25 29.5 30 27 74.5 64.5 15 17.5 12 16 10.5 19.5 14 14.5 9 8.5 20.5 14 REC 32 32 33 33.5 30.5 78 68 15 19.5 12 18 10.5 21.5 14 16.5 9 8.5 22.5 16 40 40 37.5 38 35 82.5 72.5 20 24.5 17 23 15.5 26.5 19 21.5 14 13.5 27.5 21 CX 50 50 43 43.5 40.5 88 78 18 28.5 15 23.5 13.5 27 17 22
23 28.2 48 18.5 5/16" 28.2 20.6 15.2 8 12.9 59 23 45.4 40.4 40 35 3/8 AS331F-03-10 AS331F-02-11 69 21 16.2 43.7 23 32.6 53.9 18.5 43.7 52.4 21 3/8" 32.6 23 18.5 10 63 19 16.2 AS331F-03-12 AS331F-03-07 56 17 12.9 38.7 20.6 25.6 45.4 13.2 44.9 54.2 22 1/4" 34.4 23 20.9 12 65 AS431F-04-10 AS331F-03-09 59 28.2 40.2 35.2 18.5 12.9 39.7 20.6 45.4 40.4 48 15.2 49.4 23 57.1 21 5/16" 32.6 25.8 18.5
B 7 2 12 6.6 11 12 A B 34 16 34 16 H Cross section AA Cross section BB (NN-1) X H G (mm) Refer to "Dimensions" of MXS25 on p.3.11-23 for one with shock absorber as symmetric.
To use a single knuckle joint or a double knuckle joint concurrently with a rod end nut, extend dimensions A/H. (To extend dimensions A/H, refer to the table below, and specify the product as Order Made -XAO.) Single/Double knuckle joint mounting A, H dimensions at using both single/ double knuckle joint and rod end nut Symbol Bore (mm) Applicable knuckle joint part No.
A A A A A Speed Home position A B C Speed no. Time Two pattern combination example (A five point movement of absolute move A and incremental move B) Acceleration no.
3 q u t y u o A !9 r e @0 !0 !2 !5 !6 !4 i A w A-A Component Parts No. Description Material Note No.
(For mounting) L6 L7 5.5 L2 (Rail mounting hole pitch: 12.5) 5 L1 One-touch fitting [4(A), 2(B) port] U side D side Applicable tube O.D.: 3.2, 1/8" 4, 5/32" 6, 1/4" One-touch fitting [1(P), 3/5(E) port] Applicable tube O.D.: 8, 5/16" (Station 1) (Station n) 59.5 P P 1 B 1 45.5 2 2 B 2 B 2 B 2 B 24.6 3/5 E 3/5 E 23 A 4 A 4 A 4 A 4 A 4 10 8.6 11.8 (For DIN rail mounting) 7.5 (Pitch) P = 10.5
Voltage Symbol Voltage 23 Single-phase 230 VAC (50 Hz) 30 Three-phase 200 VAC (50 Hz) 200/220 VAC (60 Hz) Options Symbol *1 Nil C G L M R T V With a timer controlled solenoid valve type auto drain (Voltage symbol 23 only) (applicable to moderate pressure *2) 22E V V V V V V V V With a terminal block for power supply, operating, and error signals *3 With Chinese labels and a Chinese operation
B A B A B A B A B A B A B 20 33 24 (32) 29 20 (28) 28.5 19.5 (27.5) 29.5 20.5 (28.5) 25 16 (24) 23.5 14.5 (22.5) 26.5 17.5 (25.5) 25 32.5 24.5 (32.5) 28.5 20.5 (28.5) 28 20 (28) 29 21 (29) 24.5 16.5 (24.5) 23 15 (23) 26 18 (26) 32 34 25 (33) 30 21 (29) 29.5 20.5 (28.5) 30.5 21.5 (29.5) 26 17 (25) 24.5 15.5 (23.5) 27.5 18.5 (26.5) 40 39 27 (36) 35 23 (32) 34.5 22.5 (31.5) 35.5 23.5 (32.5)
With auto switch Bore size (mm) A B A B 82 23 33 72 82 10 to 50 75, 100 33 32 Rod end nut 38.5 Rear flange type: CLQG32 54.2 48 34 7 32 B + Stroke 8 A + Stroke 4-5.5 65 56 Rear flange type (mm) Stroke range Without auto switch With auto switch Bore size (mm) A B A B 80 23 33 70 80 10 to 50 75, 100 33 32 Rod end nut 28.5 Double clevis type: CLQD32 10 hole H10 Shaft d9 5 4-M5 x 0.8 Cap bolt
(P/R port) (Mounting holes) 70.6 (GZ, GS: 71.3) [72.3] 8 P R P R SY A A A A 39 23 SYJ 10.5 VK (Lead wire length) G: 300 H: 600 VZ (Pitch) L1 L2 P=19 15 VT 5 Manual override Depress and turn to operate and lock override.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
A 10 () (+) White Black AXT100-DS25-030 Station 10 SOL. B 23 () (+) Gray Red 11 () (+) White Red AXT100-DS25-050 SOL. A When using a standard commercial connector, use a type 25P female connector conforming to MIL-C-24308. Station 11 SOL. B 24 () (+) Black White 12 () (+) Yellow Red SOL. A Station 12 SOL.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Normally open Normally closed Model Grommet Electrical entry Conduit Conduit terminal Bracket H F E D C B f M L K J A e 57 62 67 b 39 45.5 49.5 Q 39 39 41.5 Q 23 23 25.5 N 61 (68) 69 (76) 79 (89) d 47 52 57 a 34 51 58 N 69 (76) 77 (84) 87 (97) N 61 69 79 c 65 78 86 Q R 57 74 81 VXP2142 , 30 30 35 20 20 23 34 43 47 29 37 43 28 35 40 3 8 8 63 80 90 59 59 62 104 (116) 118 (136) 133 (150) 26
22 20 23 22 23 22 27 23 22 27 25 24 27 25 24 27 4 2.5 10 10 27.5 20.8 13 15.5 1.5 19.3 3 10 27.2 20.5 13 19.3 10 6 4 12 3 15.2 12 14 12 23 23.3 30.2 23.5 15.7 16 17 15.7 16 17 15.7 17 15.7 18.8 17 15.7 18.8 19 17.7 18.8 19 17.7 18.8 30.2 23.5 4 5 24.3 23 23.3 24.3 23 24.3 23 27.3 24.3 23 27.3 27.5 26.2 27.3 27.5 26.2 27.3 19 30.2 23.5 8 16.2 12 14 16 30.2 23.5 5 6 25 30.2 23.5 27 12 31.8