Supply pressure [MPa] Flow Rate Characteristics Relief Characteristics Supply pressure: 1.0 MPa Supply pressure: 1.0 MPa 1.0 1.0 0.9 0.9 0.8 0.8 Set pressure [MPa] Set pressure [MPa] 0.7 0.7 0.6 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0 500 1000 1500 2000 0 100 200 300 400 500 600 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 960 ITVH2000 Series 3.0 MPa Maximum Supply Pressure
JIS symbol Double acting Minimum Strokes for Auto Switch Mounting Stroke Long stroke (2) (mm) Max stroke (mm) Number of switches Bore size (mm) Standard stroke (1) (mm) Auto switch model 2 1 D-C7/C8 D-B5/B6 D-H7 D-G5/K5 25, 50, 75, 100, 125, 150, 200 201 to 350 20 15mm 10mm 301 to 400 25 301 to 450 32 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 15mm 1500 301 to 800 40 D-B59W 301 to 1200
06, 07 10 6 4 500 5 2 0 5 10 0 0 0 5 10 Needle rotation (Turns) Needle rotation (Turns) 4.1-14 Speed Controller with Residual Pressure Release Valve Series ASlFE With One-touch Fittings Model Residual pressure can be easily released with one push of button.
(Except for 1E to 3E) (Except for 1E to 3E) Refrigerant Coefficient of ozone depletion-Zero Model Air flow capacity Outlet air pressure dew point Rated inlet condition l/min(ANR) 50Hz 60Hz 100 200 310 500 740 1200 1650 310 500 740 110 220 350 570 810 1300 1820 350 570 810 IDF1E IDF2E IDF3E IDF4E IDF6E IDF8E IDF11E IDU3E IDU4E IDU6E Inlet air of normal temperature 35C Saturation 0.7MPa 10C
Double acting, single rod w/XB13, XC8, XC9, XC10 or XC11; Double acting double rod w/XC10; XB13 capable of low speeds range of 5 to 50 mm/sec; XC8 option has adjustable stroke in the extend direction; XC9 option has adjustable stroke in the retract direction; XC10 is dual stroke with 4 positions (double rod type); XC11 is dual stroke with 3 positions (single rod type); Bore sizes (mm): 20
Double acting, single rod w/XB13, XC8, XC9, XC10 or XC11; Double acting double rod w/XC10; XB13 capable of low speeds range of 5 to 50 mm/sec; XC8 option has adjustable stroke in the extend direction; XC9 option has adjustable stroke in the retract direction; XC10 is dual stroke with 4 positions (double rod type); XC11 is dual stroke with 3 positions (single rod type); Bore sizes (mm): 20
Double acting, single rod w/XB13, XC8, XC9, XC10 or XC11; Double acting double rod w/XC10; XB13 capable of low speeds range of 5 to 50 mm/sec; XC8 option has adjustable stroke in the extend direction; XC9 option has adjustable stroke in the retract direction; XC10 is dual stroke with 4 positions (double rod type); XC11 is dual stroke with 3 positions (single rod type); Bore sizes (mm): 20
L3 (1) Model Port size Max. 1 4 1 2 120 150 AS800 AS900 74 93 204 262 192 250 80 94 1 1 , 2 Note 1) L3: Reference dimensions Note 1) L3: Reference dimensions 655
Gateway (GW) Unit IP65 compliant Specifications EX500-GDN1 Model EX500-GAB1-X1 EX500-GPR1A EX500-GMJ1 Applicable PLC/ Communication protocol Rockwell Automation PLC PROFIBUS-DP (EN50170) DeviceNet Release 2.0 CC-LINK Ver. 1.10 9.6/19.2/45.45/93.75/ 187.5/500 kbit/sec 1.5/3/6/12 Mbit/sec Communication speed 125/250/500 kbit/sec 156/625 kbit/sec 2.5/5/10 Mbit/sec 57.6/115.2/ 230.4 kbit/sec
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series IDUS Series IDUS Inlet air temperature C Model IDUS3E IDUS4E IDUS6E 500 310 55 740 Air flow capacity l/mim(ANR) 295 (300) 475 (430) 703 (640) 60 160 275 225 55 Power consumption W 165 (189) 230 (275) 280 (295) 60 ( ): Previous model IDU3D/4D/6D
CN1IF(CONT) 18 - (LEC)(LEC) 5.4 CN2PC/TB (LEC)(LEC-T1-3*G*)(LEC-W2) CN2SWOFF(LEC)(LEC) (LEC-T1-3*G*)(LEC-W2) (1) CN2 (3m) (2) (USB) 120.3 120.3 mm mm 200 200 mm/s mm/s USB (A-miniB type) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 () 9.
Insulation resistance 50 M or more at 500 VDC (between lead wire and case) 1500 VAC for 1 min. Note 1) (between lead wire and case) 1000 VAC for 1 min.
CAT.EX30-1 A Stainless Steel Heat Exchanger Type Air Dryer Series IDUS Series IDUS Inlet air temperature C Model IDUS3E IDUS4E IDUS6E 500 310 55 740 Air flow capacity l/mim(ANR) 295 (300) 475 (430) 703 (640) 60 160 275 225 55 Power consumption W 165 (189) 230 (275) 280 (295) 60 ( ): Previous model IDU3D/4D/6D Series IDFS Series IDFS Inlet air temperature C Model IDFS6E IDFS8E IDFS11E 740
In addition, 3 of the wiring types are available with IP65 enclosures. 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQ5100--04 VQ5101--04 IP65 compatible Enclosure Individual wiring type
500 400 300 250 KS KX 1500 1200 1200 1000 1000 6 12 14 20 22 Starting Torque Nm x 10-3 An ambient atmosphere that causes rust is non permissible.
Stainless Steel Heat Exchanger Type Air Dryer Series IDUS Series IDUS Inlet air temperature C Model IDUS3E IDUS4E IDUS6E 500 310 55 740 Air flow capacity l/mim(ANR) 295 (300) 475 (430) 703 (640) 60 160 275 225 55 Power consumption W 165 (189) 230 (275) 280 (295) 60 ( ): Previous model IDU3D/4D/6D Series IDFS Series IDFS Inlet air temperature C Model IDFS6E IDFS8E IDFS11E 740 35 1200 1650
Bore sizes: 10, 15, 25 mm; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1200 mm (25 bore); Minimum operating pressure: 0.2 MPa (29 psi); Speed: 50 ~ 500 mm/sec.
Bore sizes: 10, 15, 25 mm; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1200 mm (25 bore); Minimum operating pressure: 0.2 MPa (29 psi); Speed: 50 ~ 500 mm/sec.
Tank model VBA2100-03 VBA2200-03 VBA4100-04 VBA4200-04 VBA2100-03 VBA2200-03 VBA4100-04 VBA4200-04 394 Rc 3/8 VBAT20 VBAT20S 305 206 674 180 200 100 400 Rc 1/2 430 Rc 1/2 444 Rc 3/8 VBAT38 VBAT38S 355 256 824 205 250 150 500 Rc 3/4 480 Rc 1/2 14-9-9
VDC Mega) Insulation resistance 10 to 500 Hz, 1.5 mm or 98 m/s2 amplitude in X, Y, Z directions for 2 hours each Vibration resistance 980 m/s2 in X, Y, Z directions 3 times each (Non energized) Impact resistance Temperature characteristics 2%F.S. or less (Based on 25C: Operating temperature range) Standard Compliant with CE Marking and UL/CSA (UL508) standards Wetted material Fitting: C3602