3 kPa)1 l/min (ANR) or less (at P2 = 0.4 MPa)0.6 l/min (ANR) or less (at P2 = 0.2 MPa)1.4 l/min (ANR) or less (at P2 = 0.6 MPa)1/4?5 to 60C (No freezing)?5 to 50C (No freezing)Bleed type0.5
Port Connections P1 = 1/4 Main In/Out NPT Ports P2 = 3/8 Main In/Out NPT Ports 1 Liter Liquid Canister Pressure Range: 29.92 Hg-125 PSI 1/2 Liter Liquid Canister COAST PNEUMATICS, INC. :: 8055 E. CRYSTAL DR :: ANAHEIM CA 92807 :: PHONE: 714.921.2255 :: FAX: 714.921.9955 :: WWW.COASTPNEUMATICS.COM
As a guide, adjust P2, so that it could be W + P2A = P0a.
Example) Lead wire length 2000 mm Electrical entry When ordering cylinder with valve CVQM32-30-M9B-5MOZ SY100-30-4A-20 M-type plug connector with lead wire (Lead wire length 300 mm) M MO M-type plug connector without connector 5 Series CVQM Dimensions 32 to 63 EXH 2 x P2 F SUP P1 S S Q 2 x HB through Manual button 2 x HA through V W 2 x 2 x OA effective length RA KA 2 x N through Y EB (KB
= 0.5 MPa 1(P) 2(B) 9.0 12.8 11.8 13.1 4(A) 5(R1) 21.3 21.4 14.4 13.1 Effective area at exhaust side (mm2) P2 = 0.5 MPa 2(B) 3(R2) 18.2 14.9 14.8 12.2 Note 1) Set the pressure within operating pressure range of solenoid valve.
Clausings factor 8 Exhaust Time (Low/Medium Vacuum) K The time (t) required to exhaust a chamber at low vacuum with volume V (L), from pressure P1 to P2, using a pump with pumping speed S (L/sec) is t=2.3(V/S)log(P1/P2). In high vacuum, this is subject to the ultimate pressure limit imposed by outgassing and leakage as characterized above.
Clausings factor 8 Exhaust Time (Low/Medium Vacuum) K The time (t) required to exhaust a chamber at low vacuum with volume V (L), from pressure P1 to P2, using a pump with pumping speed S (L/sec) is t=2.3(V/S)log(P1/P2). In high vacuum, this is subject to the ultimate pressure limit imposed by outgassing and leakage as characterized above.
Set pressure Inlet pressure P1: 0.5 MPa Outlet pressure P2: 0.1 MPa Fluid: Water Model: SRF30 0.5 Inlet pressure 0.45 Piping Caution 0.4 Pressure (MPa) 0.35 0.3 1. Connecting tubes with special tools. Refer to the pamphlet: High-Purity Fluoropolymer Fittings Hyper Fittings/LQ1,2 Series Work Procedure Instructions (M-E05-1) for tube connection and special tools. 2.
As a guide, adjust P2, so that it could be W + P2A = P0a.
Weight (kg) 4.5 2.5 1.1 0.7 Note 1) Outlet pressure range: P2 is 90% of P1 or less. Note 2) Air consumption differs depending on the set pressure. Due to the construction, the pressure gap between inlet and outlet cannot be set within 0.03 MPa, even if the knob is set at the maximum. Accessory (Option)/Part No. Part no.
CYLINDER, P2, 63MM CKZN SLIM LINE CLAMP CYL, 3.63660 lb
CYLINDER, P2, 63MM CKZN SLIM LINE CLAMP CYL, 4.05900 lb
SLIM LINE CLAMP CYLINDER, P2, 63MM CKZN SLIM LINE CLAMP CYL, .64480 lb
IBV1 Series SMC Corporation 1.Index 1Table of contents P1 2Specifications P2 3Features P2 4External dimensions drawing P3 5How to mount a nozzle P4 6Relationship between Upstream Piping and Peak Pressure P5 7Safety Instructions P6~10 1 2.
Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) 400 Effective area mm2 Effective area mm2 Effective area mm2 6 12 1000 15 300 8 4 500 10 200 500 4 2 5 100 10 5 0 10 5 0 10 5 0 Number of needle rotations Number of needle rotations Number of needle rotations Pressure Characteristics (ASR) ASR430F, ASR530F ASR630F 0.4 0.4 Set pressure 0.3 MPa Set pressure 0.3 MPa 0.3 0.3 P2
S1 S2 Preset pressure OFF OFF P1 ON OFF P2 OFF ON P3 ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to 0MPa. 1.12-16
= 0.5 MPa Effective area at supply side (mm2) S at P1 = 0.7 MPa, P2 = 0.5 MPa Note 3) 5.1 1.9 PA 5.8 2.1 PB Note 3) 12.6 4.5 AEA 12.6 4.5 BEB 1-5-80
= 0.5 MPa 31 Effective area at exhaust side (mm 2) S at P2 = 0.5 MPa Note 1) Maximum operating pressure of solenoid valve is 0.9 MPa.
Note 4) Interface regulator is only capable of regulating the P port pressure. 0.06 1.9 2.1 4.5 4.5 P A P B A EA B EB Effective area at supply side (mm2) (3) S at P1 = 0.7 MPa, P2 = 0.5 MPa Effective area at exhaust side (mm2) (3) S at P2 = 0.5 MPa How to Order Solenoid Assembly Non plug-in type C DXT170 5 L Flow Characteristics {1(P) 4(A)} Conditions: Inlet pressure setting 0.7 MPa
(inch) Connection thread UNF NPT H (Width across flats) Min. port size D1 Note) D2 L1 P2 A Weight (g) Model L2 M P1 L3 1 8 1 8 5 32 3 16 KQ2ZD01-34S KQ2ZD03-34S KQ2ZD05-34S KQ2ZD07-34S KQ2ZD07-35S KQ2ZD07-36S KQ2ZD09-35S KQ2ZD09-36S KQ2ZD09-37S KQ2ZD11-35S KQ2ZD11-36S KQ2ZD11-37S KQ2ZD13-36S KQ2ZD13-37S 14.29 14.29 14.29 9.6 10.4 11.4 37 37 37 37.5 38.5 40.5 45 45.5 47.5 52 52.5 54 60.5