Grinding fluid (Grinding machines) Fiber element Polypropylene 10 Grinding fluid (Oilstone) Fiber element Polypropylene 10 Lubricating oil Fiber element Polypropylene 50 Cooling water Fiber element Polypropylene 10 Cleaning water Fiber element Polypropylene 10 Developing fluid Fiber element Cotton 50 Lacquer Fiber element Cotton 10 Nitrogen gas Fiber element Cotton 10 Carbon dioxide Fiber

200 10 125 15 15 + 55(n-2)/2 n = 2, 4, 6, 8 20 20 + 55(n-2)/2 n = 2, 4, 6, 8 20 20 20 + 55(n-2)/2 n = 2, 4, 6, 8 25 25 + 55(n-2)/2 n = 2, 4, 6, 8 10 100 35 100 + 100(n-2) n = 2, 3, 4, 5 35 + 30(n-2) n = 2, 3, 4, 5 10 55 35 55 + 55(n-2) n = 2, 3, 4, 5 35 + 30(n-2) n = 2, 3, 4, 5 10 10 + 40(n-2)/2 n = 2, 4, 6, 8 10 10 + 40(n-2)/2 n = 2, 4, 6, 8 10 10 + 30(n-2)/2 n = 2, 4, 6, 8 15 10 + 45(n

10 28.4 (Mounting holes) 3.5 25 2.5 5 5 10 22 16.4 10 3.2 222 4 (Mounting holes) Manual override (Non-locking) M3 0.5 (Pilot port) M3 0.5 (Pilot port) A B 11 17.5 1(Bleed port) 1.5 A B 1.5 1.5 5-M3 0.5 (Piping port) 33 36 Manual override (Non-locking) B P R R 7 7 36 2 35 7 13.5 28.5 15 A 21 R2 P R1 13 1(Bleed port) 11 10 4 15 10 10 5-M5 0.8 (Piping port) 14 14 15 (Bracket) 2 Position double

Add an asterisk () at the beginning of electro-pneumatic regulator part numbers to be mounted.

to 40 39.5 31.5 6 6 29 5.5 10 38 5 8 20 3.5 6.5 M6 x 1.0 7 18 10 5 M4 x 0.7 10 to 60 44 34 8 8 36 5.5 16 47 7 10 25.5 5.4 9 M6 x 1.0 7 19.5 10 6 M5 x 0.8 10 to 60 47.5 37.5 10 10 40 5.5 20 52 8 10 28 5.4 9 M6 x 1.0 7 23 10 49.5 7 M6 x 1.0 10 to 50, 75, 100 54 42 12 12 45 8.5 25 60 4.5 10 12 34 5.5 9 M6 x 1.0 7 26 10 57 10 M8 x 1.25 10 to 50, 75, 100 60.5 48.5 13 16 52 8.5 28 69 5 14

0 10 20 30 40 50 60 50 60 40 30 20 10 0 10 20 30 Atmospheric pressure dew point ( C) 14-19-10 7 Membrane Air Dryer Series IDG Calculation of inlet air flow rate Q1, and confirmation of compressed air supply capacity.

Description Material Q'ty VFR VVQ5000-80A-1 Gasket HNBR 10 Type VVQ5000-80A-2 Gasket HNBR 10 Option VQ7 A For 1 station Note) Spare parts consist of sets containing 10 pcs. each.

UPPER AND LOWER LIMIT ARISES -9-2 FIG. 10-1 MOISTURE AIR DIAGRAM -10-3 vi Contents Table List Page No.

M2 M3 m2 m3 16 20 25 32 40 50 63 16 20 25 32 40 50 63 6.0 3.0 1.0 18 7 2.1 10 5.2 1.7 26 10.4 3 15 9.0 2.4 38 15 4.5 MY1MW 30 15 5.0 57 23 6.6 59 24 8.0 84 33 10 115 38 15 120 48 14 140 60 19 180 72 21 6.0 3.0 2.0 18 7 2.1 10 5.0 3.0 25 10 3 15 8.5 5.0 35 14 4.2 30 14 10 49 21 6 MY1CW MY1B 60 23 20 68 30 8.2 115 35 35 93 42 11.5 MY1H 150 50 50 130 60 16 The above values are the maximum allowable

Install an earth leakage breaker Note) suitable to each model for the power supply. Maintain voltage fluctuation within 10% of the rated voltage. Note) Select an earth leakage breaker with a sensitivity current of 30 mA. As regards rated current, refer to Applicable earth leakage breaker capacity on page 3.

Standard Stroke Model Standard stroke (mm) 10, 20, 30, 40, 50 MXQ6 10, 20, 30, 40, 50, 75 MXQ8 10, 20, 30, 40, 50, 75, 100 MXQ12 10, 20, 30, 40, 50, 75, 100, 125 MXQ16 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ20 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ25 8-5-9 10 Series MXQ Theoretical Output IN OUT The dual rod ensures an output twice that of existing cylinders.

Option L . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 SPECIFICATIONS . 10-1 10.3 MOUNT THE HEAVY DUTY AUTO DRAIN . 10-2 10.4 MAINTENANCE . 10-2 Chapter 11 Option R .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 EARTH LEAKAGE BREAKER SPECIFICATION . 11-1 11.3 CONNECTION OF POWER SUPPLY . 11-2 Chapter 12 Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR

0 0 4.5 0 2 9.5 8 ML2B 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 8.5 7.5 6 5 2.5 3 9 4.5 6.5 14 12.5 1.5 2 8 3.5 5.5 13 11.5 12 10 9.5 7.5 6 6.5 4.5 8 10 17.5 16 4 4.5 12.5 6 8 15.5 14 13.5 12.5 11 10 7.5 8 14 9.5 11.5 19 17.5 6.5 7 13 8.5 10.5 18 16.5 D-A9 and D-A9V cannot be mounted on 50.

When in the locked state, do not apply a load accompanied by an impact shock, strong vibration or turning force, etc. Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 2. Consider stopping accuracy and the amount of over-run when an intermediate stop is performed.

When in the locked state, do not apply a load accompanied by an impact shock, strong vibration or turning force, etc. Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 2. Consider stopping accuracy and the amount of over-run when an intermediate stop is performed.

[C] 5 10 15 20 25 30 35 Circulating fluid temperature [C] HRS090-W-20/40 (50 Hz) HRS090-W-20/40 (60 Hz) 14 12 12 10 Facility water temperature 32C Facility water temperature 32C Cooling capacity [kW] Cooling capacity [kW] 10 8 8 6 Facility water temperature 40C Facility water temperature 40C 6 4 4 2 2 0 0 5 10 15 20 25 30 35 Circulating fluid temperature [C] 5 10 15 20 25 30 35 Circulating

If the tank lid is opened after the supply of circulating fluid, the circulating fluid may spill out depending on the condition of the external piping. 10. If an external tank is used, the circulating fluid may spill out from the internal tank lid depending on where the external tank is installed. Confirm that the internal tank has no leakage if using an external tank. 11.

2 pcs. 10 10 25 to 5 20 15 5 1 pc. 10 10 25 CXTl25 5 15 10 10 2 pcs. 10 15 20 CXTl 32 40 5 15 10 5 1 pc. 10 10 20 (mm) D-F7lW D-J79W D-F9BAL D-F7NT D-F79F Auto switch model D-A7l D-A8l D-A73C D-A80C D-A7lH D-A80H D-F7l D-J79 D-F7lV D-J79C Applicable model D-F7lWV D-A79W D-F7LF Number of mountings 2 pcs. 5 10 15 15 20 20 25 CXTl 32 40 1 pc. 5 5 10 15 15 20 25 3.8-10 Platform Cylinder Series

For a 10 orifice (VXS23/Port size 1/4), P 0.05 MPa The optimum size for a pressure differential of P 0.2 MPa and a flow of 50 L/min will be the VXS23 (10 orifice, port size 3/8). 500 400 VXS26 25 Cv = 12 300 VXS25 20 Cv = 9.2 200 VXS24 15 Cv = 5.3 Flow rate Q [L/min] 100 VXS23 Port size 3/8 10 Cv = 2.8 VXS23 Port size 1/4 10 Cv = 2.4 50 40 30 25 20 10 0.01 0.02 0.03 0.04 0.05 0.1 0.2 0.3