CDU Double Acting, Single Rod D-A9, D-A9V D-M9, D-F9W D-M9V, D-F9WV Bore size (mm) B W A W W B B A A 6 10 16 20 25 32 3.5 4.5 17.5 6.5 0.5 3.5 13.5 17.5 2.5(5) 7.5 0.5 16.5 2.5 3.5 7.5 12.5 16.5 1.5(1) 8 0.5 20 1.5 4 8 16 20 2(0.5) 10 2 24 0 6 10 20 24 4(1.5) 11 3.5 26.5 1.5 7 11 22.5 26.5 5.5(3) 12.5 4.5 27.5 2.5 8.5 12.5 23.5 27.5 6.5(4) Note 1) Figures in the table above are used as a
A A Solid state auto switch D-M9B, D-M9N Reed auto switch D-A93 (mm) (mm) Stroke (mm) 20 41 29 47 35 Stroke (mm) 20 45 25 51 31 Auto switch operating range Auto switch operating range 15 40.5 20.5 Model Model 25 50.5 30.5 30 59 39 10 35 15 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 A B A B A B A B A B A B 11-/22-MXP10 11-/22-MXP10 11-/22-MXP12 11-/22-MXP12 3 5 11-/22-
IDX-OM-W014-C / Series IDU3E-10(-C,K,L,M,R,S,T) IDU3E-20(-C,K,L,M,R,T) IDU4E-10(-C,K,L,M,R,S,T) IDU4E-20(-C,K,L,M,R,T) IDU6E-10(-C,K,L,M,R,S,T) IDU6E-20(-C,K,L,M,R,T) IDU3E-23(-C,K,L,R,T,V) IDU4E-23(-C,K,L,R,T,V) IDU6E-23(-C,K,L,R,T,V) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 * 1) JIS B8370 *2 ) *1) ISO 4414
40A) R Rc N NPT F G 1 Seals and washers are included. r Fluid and ambient temperatures Symbol B 40 to 60C t With/without silencer Port size 06 10 14 Nil Without V V V S With V y Pilot port size Nil 1/4 1 1/8 1 2 (OUT) Port size: 14 only Select Nil for 06 and 10.
series 10 11 Relief type Vacuum suction type M9BW R Z 60 16 A R 2 J D C 10 B M9BW R Z 60 16 A R 2 J D C 21 B Bore size (mm) Number of auto switches Built-in magnet Cylinder stroke (mm) Nil Type of auto switch Nil No Nil S n 2 pcs. 1 pc. n pcs.
(Equivalent lead (8)Cable length * [m] (7)Cable type (9)Driver type Power supply Without cable Nil Without cable Nil Compatible drivers voltage [V] Standard cable 3 3 S R Nil Without driver Robotic cable (Flexible cable) 5 5 200 to 230 200 to 230 M2 LECYM2-V A 10 U2 LECYU2-V C 20 * The length of the motor and encoder cables are the same.
4 (A) 4 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) How to Order Manifold Base 2 position double 2 position double (B) 2 (A) 4 (B) 2 (A) 4 Same manifolds as series SYJ3000 are prepared. 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) SS5YJA3 Fill the same as SS5YJ3 3 position closed center 3 position closed center (B) 2 (A) 4 (B) 2 (A) 4 Instruct by specifying the valves and blanking plate assembly to be mounted on the
(mm) (mm) Stroke 5 10 15 20 25 30 40 50 75 100 Y 12.5 15 15 20 20 15 17.5 17.5 25 30 Q 20 20 20 20 30 E 68 68 70.5 68 70.5 68 70.5 75.5 80.5 83 11-10-15 16 Refer to page 11-11-1 concerning further information on specifications of the auto switch single body.
cable 6.8 to 9.6) Auto Switch Proper Mounting Positions (mm) Solid state auto switch Reed auto switch D-G5/K59 D-G5W/K59W D-G59F/G5BA D-G5NT A 10 8 15 19.5 D-H7 D-H7W/H7C D-H7NF/H7BA D-M9(V) D-M9W(V) D-M9A(V) D-C7/C80 D-C73C/C80C Bore size (mm) D-A9(V) D-B5/B64 D-A3/A44 D-G39/K39 D-B59W A 8 6 13 17.5 A 8.5 6.5 13.5 18 A 11.5 9.5 16 21 A 8 6 13 17.5 A 18 16 23 27.5 B 17 19 18 23.5 A 13.5
side of A port Nil 1 8 01 Rc VFN Nil Rc G NPT NPTF C4 4 cassette P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 F N T Same side of A port S C6 6 cassette Valve stations Type S42 (Solenoids on the same side of A port) 01 1 station 20 20 stations P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 Common SUP/Individual EXH How to Order Type 21: Body ported (A port top ported) Applicable solenoid valve
D-F9W 12 A B W 16, 20, 25 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com W A B 32, 40 D-A9 D-M9 D-F9W Auto switch model D-F9BAL Symbol A B W A B W A B W Standard Stroke 12 16 20 25 32 40 5.5 6 2.5 0.5 1 1.5 4.5 4 7.5 9.5 9 11.5 5.5 6 10 11 12 16 14.5 15 11.5 9.5
OYTOT MSA 1010.02 Yes '/f t2) Yes MBA 10't r.02 11 Yes 't"et t ' l Z YE MAA 4210.02 t6 Y5 v." 11) v.' t2\ t " t2:l t ' l a STATX)flS 2 3 a 5 6 7 I t t0 -1 nm) 5 .
5 V, 12 V 24 V IC circuit Diagnostic indication (2-color display) Grommet 12 V 5 V, 12 V 2-wire Water resistant (2-color display) 4-wire (NPN) IC circuit With diagnostic output (2-color display) Solid state switches marked with a "" are produced upon receipt of order.
10 A IDU3E-10, IDU4E-10 IDU6E-10 30 mA IDF4E-20, IDF6E-20 IDF8E-20, IDF11E-20 Type 200 V 5 A IDU3E-20, IDU4E-20 IDU6E-20 S Option symbol IDF1E-10 to 11E-10, IDU3E-10 to IDU6E-10 With power cord connection The option allows the connection of a power cord to a terminal block.
4 x M2.5 x 0.45 thread depth 2.5 12.5 K Bottom view of MXQ6-30 13223 6.5 20 16 13 3.5 0.3 19.2 20 Z ZZ G (NN 1) x H H 10.5 5.5 10.5 5.5 A B 3H9( ) depth 2.5 +0.025 0 3.2 3.2 6.3 7 7 12 1 A B NN x M4 x 0.7 thread depth 8 4 3H9 ( ) depth 2.5 +0.025 0 HA GA A-A B-B (mm) Model F 22 25 21 26 27 N 4 4 6 6 6 G 6 13 11 21 H 23 26 28 28 NN 2 2 3 3 3 GA 13 13 29 39 49 HA 16 26 20 28 28 I 9 9 9 16
Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V 24 V 12 V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) Diagnostic indication (2-color indication) IC circuit 5 V, 12 V 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since
Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V 24 V 12 V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) Diagnostic indication (2-color indication) IC circuit 5 V, 12 V 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since
A or less 24 VDCj 10pA or less 1.5 V or less (10mA: 0.8 V of less) 24 VOCj 1opA or less R e d : O N 1 mS or less solid state switch 3 Wirc lC circuit 28 VDC l5OmA 0.8 V or less 2 V or less (10mA: 0.8 V or less) 24 VDC: 10pA or less 24 VDC] 10llA or less ON: red light emilUng diode ON: red lighl milling diode 1 mS or less ftlo$I{ildl Smies CIA Reed Type Internal Circuit D-A59W.
20 20 20 20 20 20 20 9.5 9.5 9.5 11.5 D-F7, F7V D-J79, J79C D-F7W, F7WV D-J79W D-F7BAL, F7BAVL D-F7NTL, F79F D-F7W D-J79W D-F7BAL D-F79F D-F9BAL 6 6 6 6.5 Number of auto switch D-F7LF D-A9 D-F9 D-A79W 7.5 7.5 8 D-F7LF 7.5 D-F9, F9V D-F9W, F9WV D-F9BAL 1 pc. 2 pcs. 20 20 20 20 25 25 20 20 5.5 5.5 5.5 6.5 The operating ranges are provided as guidelines including hystereses and are not guaranteed
IDX-OM-W094 / Series IDFA60-23-A,C,L,R,T,V IDFA70-23-A,C,L,R,T,V IDFA80-23-A,C,L,R,T,V IDFA90-23-A,C,L,R,T,V URLhttp://www.smcworld.com/ English instruction manual can be downloaded from our URLhttp://www.smcworld.com/ SMC ISO4414 *1) JIS B8370 *2) *1) ISO4414Pneumatic fluid power Recommendations for the application of equipment to transmission and control systems. *2) JIS B8370 URLhttp: