HRS090 AND LARGER CAPACITIES. Dual Channel Chiller for Lasers. 315.00000 lb. O88.
HRS090 AND LARGER CAPACITIES. Dual Channel Chiller for Lasers. 380.00000 lb. O88.
HRS090 AND LARGER CAPACITIES. Dual Channel Chiller for Lasers. 260.00000 lb. O88.
HRS090 AND LARGER CAPACITIES. Dual Channel Chiller for Lasers. 260.00000 lb. O88.
HRS090 AND LARGER CAPACITIES. Thermo Chiller. 255.00000 lb. O88.
Cooling Capacity: 150 (15.7kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: MW (M + W)
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: M (Applicable to DI Water Piping)
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: 150 (15.7kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AMW (A + M + W)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: M (Applicable to DI Water Piping), High Pressure Pump: T1 (Inverter Pump Mounted)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T1 (Inverter Pump Mounted)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T1 (Inverter Pump Mounted), Feet: None, Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T1 (Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping), High Pressure Pump: T1 (Inverter Pump Mounted)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping), High Pressure Pump: T2 (High Pressure Inverter Pump Mounted)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: M (Applicable to DI Water Piping), High Pressure Pump: T2 (High Pressure Inverter Pump Mounted)
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: A (w/Caster Adjuster-foot)
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)