A 35.5 44.5 52.5 76.5 79.5 83 A 37 46 54 78 81 84.5 B 5.5 12 16 38 43 40.5 A 41 50 58 82 85 88.5 B 9.5 16 20 42 47 44.5 A 38 47 55 79 82 85.5 B 6.5 13 17 39 44 41.5 B 7 13.5 17.5 39.5 44.5 42 A 43.5 52.5 60.5 84.5 87.5 91 B 12 18.5 22.5 44.5 49.5 47 B 4.5 10.5 14.5 36.5 41.5 39 CE1 CE1 12 20 32 40 50 63 CE2 ML2B Note) Adjust the auto switch after confirming the operating conditions in the
B A B A B A B C D Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.
Select an air filter with a filtration size of 5 m or smaller. 2. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause a malfunction of pneumatic equipment such as valves.
Use a cylinder with a built-in cushion mechanism. When a driven object is stopped, ensure the impact force of the object being transferred to the floating joint is prevented by using a cylinder with a built-in cushion mechanism (rubber cushion or air cushion). To stop the cylinder at the intermediate position, use an external shock absorbing mechanism such as a shock absorber.
11.5 46.5 D-F7V D-J79C D-F7 D-J79 D-A9 D-A9V D-F9W D-F9WV D-M9V D-M9 D-A79W D-A72 D-A73 D-A80 D-F9BAL D-P5DWL D-P5DWSC Model A 8.5 43.5 A 11 46 A 13 48 B CKQ CLKQ B B B B B B A 14 49 B B A 14 49 B A 14 49 B A 7 42 A 10 45 A 11.5 46.5 A 11 46 19 or more 17 or more 33 or more 27 or more 28 or more 27 or more 22 or more 30 or more 22 or more 17 or more 54 or more 52 or more Auto Switch Mounting
YES When positioning at the outside of the allowable range, do you have any problem in doing a trial once again? How to manually change from an unlocked state to a locked state To change from an unlocked state to a locked state: Unlike the procedure for manually disengaging the lock, never rotate the pin by striking it, as it could bend or damage the pin.
Nil N Assembled as a unit Spacer only Spacers are used to fix the stroke adjustment unit at an intermediate stroke position. Spacers are shipped in 2 piece sets.
HS Auto switch 36 12 24.5 SMC SMC A 33 B Auto switch 49.5 A B G 1/2 (applicable cable O.D. 6.8 to 11.5) Proper auto switch mounting positions (mm) D-H7 D-H7C D-H7W D-H7BAL D-C7 D-C8 D-C73C D-C80C D-G39 D-K39 D-A33, D-A34 D-A44 D-B5 D-B6 D-G5NTL D-H7F D-B59W Bore size (mm) A A B A A A A B A B B B B B 20 14 10 8.5 12 10.5 14 9 15 13 12 6.5 8.5 12 7 25 14.5 12.5 9.5 9 11 14.5 9.5 12.5 15.5 11.5
Use caution when handling a cylinder, which is running at a high speed and a high frequency, because the surface of the cylinder tube could get hot enough to burn you. 3. Do not use the air cylinder as an air-hydro cylinder. The use of turbine oil as a fluid for an air cylinder may result in oil leakage. 4. The oil stuck to the cylinder is grease. 5.
Proper Mounting Position (Detection at Stroke End) and Mounting Height 32, 40, 50, 63 D-M9/D-M9W/D-A9 D-M9V/D-M9WV/D-A9V Hs B W A A A B (mm) D-A9V D-A9 D-M9 D-M9W D-M9V D-M9WV A B A B Bore size (mm) W Hs A B W A B Hs 32 40 50 63 12 [17] 9 1 12 [17] 9 29 8 [13] 5 3 (0.5) 8 [13] 5 27 16 11.5 1.5 16 11.5 32.5 12 7.5 5.5 (3) 12 7.5 30.5 14 <19> 14.5 4.5 14 <19> 14.5 42 10 <15> 10.5 8.5 (6)
Contact SMC if hysteresis causes an operational problem. Connection To connect a switch unit to a contact protection box, connect the lead wire from the side of the contact protection box marked SWITCH to the lead wire coming out of the switch unit.
D-B5/B64 D-G5/K59 D-G5W/K59W (A set of band and screw) BA-02 BA-01 (A set of band and screw) BA-32 (A set of band and screw) BA-04 (A set of band and screw) BA-05 (A set of band and screw) BA-06 (A set of band and screw) BA-08 (A set of band and screw) BA-10 (A set of band and screw) Note) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform,
Some fluids can deteriorate a seal or an O-ring, and have an affect on the filter function, causing leakage. The wetted parts of the pressure gauge is made of brass. Check the compatibility with fluid in use. EB ES 1. Failure to observe the procedure will likely cause fluid leakage or removal of a cover, which may lead to an unexpected accident.
Heavy duty scraper Lube-retainer Lube-retainer Fingers synchronized by a rack and pinion mechanism A large amount of gripping force is provided through the use of a double piston mechanism, while maintaining a compact design. Double-end type oil-impregnated resin bearings are used for all shafts. An auto switch can be mounted at 4 locations.
m (kg) When an actuator is operated under conditions that exceed the lines in the graphs above, be sure to use a regenerative absorption unit.
Applicable air preparation equipment VHS20 VHS30 VHS40 VHS40-06 VHS50 Y200-A Y300-A Y400-A Y500-A Y600-A AC20-A AC25-A, AC30-A AC40-A AC40-06-A AC50, AC55 Note), AC60 Note) Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A Note) VHS50 can be connected to AC55 and AC60.
-tn rommet Termina DIN Connector NWsFR3 -10 t Series NVFR3000 Manifold valve a Individual wiring for each valve a Port size Non plug-in type See 'How to Order Manifold Assemblies," pg. 46 Manifold S ifieations a Base mounted VPe Wiring soecitiPort size I'Jo. of Statioos Applicable solenoid valve A,B port P,EA,EB A,B Plug-in type NW5FB3.O1T With terminal blocks Side, Bottom % NPTF 2-10 NVFR3OOO-OF