In addition, it can relay output as an alarm contact output when an alarm is generated. Alarm Alarm code Alarm description Operation status Main reason AL0 Memory error Stop There is an abnormality with the memory data in the controller due to a high level of noise. AL1 Controller error Stop There is an abnormality with the data in the controller due to a high level of noise.

When ordering nuts as spare parts, size 4 and 5 are as shown below.

Single flat Single flat D D D D D D D D C Single flat Single flat (mm) 15 9 18 20 10 20 30 13 22 40 15 30 10 8 14 Size C D Note ) Dimensions and tolerance of the shaft and single flat (a parallel keyway for size 40) are the same as the standard.

Cannot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 3.

Do not install in Zone 0 (as defined in IEC 60079-101:2008) or Zone 20 (as defined in IEC 60079-10-2:2009) Zone 0 area classification: An area in which an explosive gas atmosphere is present continuously or for long periods or frequently.

The displayed value to the sensor input can be set as required. (Voltage input: 1 to 5 V/Current input: 4 to 20 mA) Pressure switch/Flow switch can be displayed. B A is displayed for 1 V (or 4 mA). B is displayed for 5 V (or 20 mA). The range can be set as required.

Do not use in an environment with temperature cycles. Consult SMC if switches are used where there are temperature cycles other than normal temperature changes, as they may be adversely affected internally. 4. Do not use in an environment where there is excessive impact shock.

Do not use in an environment with temperature cycles. Consult SMC if switches are used where there are temperature cycles other than normal temperature changes, as they may be adversely affected internally. 4. Do not use in an environment where there is excessive impact shock.

Do not use in an environment with temperature cycles. Consult SMC if switches are used where there are temperature cycles other than normal temperature changes, as they may be adversely affected internally. 4. Do not use in an environment where there is excessive impact shock.

Since the dimensions of mounting style is the same as pages 6-4-13 to 6-4-20, refer to those pages.

Bore size/Stroke (mm) 6 10, 20, 30, 40, 50 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Adjuster option Nil Without adjuster Functional option AS Extension end adjuster AT Retraction end adjuster Nil Standard A Both ends adjuster P Note) Axial piping CS Extension

Main applications Cotton Stainless steel 304 20 to 100 0.5, 1, 5, 10, 20, 50, 75, 100 0.2 MPa 0.1 MPa Polypropylene Polypropylene 0 to 60 0.5, 1, 5, 10, 20, 50, 75, 100 Glass fiber Stainless steel 316 1, 5, 10, 20 0 to 400 Note) Size for all is 65 x L250. Different lengths are available as a special order up to 750 mm, only for cotton and polypropylene. Elements Part No.

by the following formula: = 10 x mg = 20 x mg mg F = x a 2 x 10 x Workpiece weight 20 x Workpiece weight Even in cases where the coefficient of friction is greater than = 0.2, for reasons of safety, select a gripping force which is at least 10 to 20 times greater than the workpiece weight, as recommended by SMC.

Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room (1 l/min flow rate).

mA D side EVS Note 1) Combining valve VFR31 (single) and release valve spacer makes it possible to use this as an air release valve.

Actuator effective torque S x Ta (S is 10 times or more) ( ) If the mass of the clamp itself in the drawing below is considered in the calculations, it should be regarded as an inertial load. ( ) If the mass of the lever itself in the drawing below is considered in the calculations, it should be regarded as an inertial load.

Equipped with an auto switch (mountable on both sides) Magnet included as standard.

Lightning surge countermeasures should be applied directly to system components as necessary. 2. The pressure sensors do not have an explosion proof rating. Never use pressure sensors in the presence of flammable or explosive gases. 20 mm or more Sheath Piping Connection Caution Insulator Cut the air tubing vertically.