It is intended as an overview and not as an all inclusive description. 1) Rotate the adjustment wheel counterclockwise (DECR) completely to relieve spring force. Then gradually open the valve at inlet side to supply gas to the regulator. 2) Close the valves on the inlet and outlet side and hold for at least 10 minutes.
The N.C. type is recommended. *6 Refer to the chemical data on page 29 for chemical resistance of the bowl. *7 A bowl guard is provided as standard equipment (polycarbonate). *8 A bowl guard is provided as standard equipment (nylon). *9 The combination of float type auto drain C and D is not available. *10 Without a valve function The mounting screws are the same as the thread of e. *11
Besides, the overall length is longer than the cylinder with air cushion as follows, because the bumpers are attached to the both sides of the piston: 32, 40: +6 mm, 50, 63: +8 mm, 80, 100: +10 mm.
Besides, the overall length is longer than the cylinder with air cushion as follows, because the bumpers are attached to the both sides of the piston: 32, 40: +6 mm, 50, 63: +8 mm, 80, 100: +10 mm.
Give adequate confirmation, and then determine a model, just because the compatibility list shows the general case. 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 101 102 103 104 105 106 107 108 109 Pa Vacuum piping direction: if the system uses a vacuum pump, we ask that you install the vacuum pump
There are no mechanical moving parts as in the case of refrigeration equipment.
9/16 21/32 21/32 11/32 11/32 9/32 9/32 10-FB3 10-FB2 10-FB4 10-FB1 10-FLB1 (Short) 10-FLB2 10-FLB2 (Short) 10-FLB1 21 Page 5 Distributed by Power Aire, Inc.
0 90 Vacuum pressure reached 80 kPa Vacuum pressure in tank [kPa] 80 Vacuum pressure [kPa] 66 kPa 70 60 53 kPa 50 40 kPa 40 26 kPa 30 20 13 kPa 10 0 Suction flow rate [L/min (ANR)] 10 0 20 30 40 50 60 70 80 90 100 1 10 Time to reach vacuum [s] 1 0 2 3 4 5 6 7 8 9 10 11 12 Vacuum Break Flow Rate Characteristics*1 (Representative value) *1 Silencer exhaust specification The graph shows the
As a guideline, unit should be replaced after approximately 10 years of use (10 hours/day operation). Replace it when the color of the dew point indicator turns white or pink, even if it is within the period.
Note 3) Not used for 10 and 12. 15-16-9 10 Series ASR/ASQ Flow Characteristics Pressure Valve: Series ASR (Inlet pressure: 0.5 MPa) ASR430F ASR530F ASR630F 20 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Effective area mm2 Effective area mm2 Effective area mm2 400 6 12 1000 15 300 4 8 500 10 200 500 4 2 5 100 10 5 0 10 5 0 10 5 0 Number of needle rotations Number of needle
to 40 39.5 31.5 6 6 29 5.5 10 38 5 8 20 3.5 6.5 M6 x 1.0 7 18 10 5 M4 x 0.7 10 to 60 44 34 8 8 36 5.5 16 47 7 10 25.5 5.4 9 M6 x 1.0 7 19.5 10 6 M5 x 0.8 10 to 60 47.5 37.5 10 10 40 5.5 20 52 8 10 28 5.4 9 M6 x 1.0 7 23 10 49.5 7 M6 x 1.0 10 to 50, 75, 100 54 42 12 12 45 8.5 25 60 4.5 10 12 34 5.5 9 M6 x 1.0 7 26 10 57 10 M8 x 1.25 10 to 50, 75, 100 60.5 48.5 13 16 52 8.5 28 69 5 14
10 39.5 51 55 133 48.5 10 36 Inch sizes H Applicable tubing O.D.
(mm) TLM0201 2 x 1 2 1 TLM0302 3 x 2 3 2 TLM0425 4 x 2.5 4 2.5 TLM0403 4 x 3 4 3 TLM0604 6 x 4 6 4 TLM0806 8 x 6 8 6 TLM1075 10 x 7.5 10 7.5 TLM1008 10 x 8 10 8 TLM1209 12 x 9 12 9 TLM1210 12 x 10 12 10 TLM1916 19 x 16 19 16 TLM2522 25 x 22 25 22 TLM1613 16 x 13 16 13 Length per roll Color Translucent Translucent Symbol N N R BU B N N N 10 m Red (Translucent) 20 m Blue (Translucent) Roll
Lead wire with connector for copying ZS-40-Y Connect up to 10 slave units 10 LFE0 Series For the flow switch precautions, refer to the Operation Manual on the SMC website.
In the case of MVGQM50-40 st, an interface of 10 mm wide is installed inside of the MVGQ50-50 st, and thus the full length dimension of the body is the same as 50 st. 20, 30, 40, 50, 75, 100 125, 150, 175, 200 25 M L MVGQ M L 32, 40 25, 50, 75, 100, 125, 150, 175, 200 MVGQ 50, 63 10-16-9 10 Series MVGQ Weight (kg) Standard stroke (mm) Bearing type Bore size (mm) Model The allowable lateral
Note) One of Nil, F or N is entered as thread symbol.
This time is characterized as =0 exp(E/RT) where R is the ideal gas constant and 0=(approx.) 10-13sec. Residence time of water at 20C is 5.5 x 10-6sec, whereas at 150C is 2.8 x 10-8 sec, or 200 times shorter.
NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber ZP02 ZP04 ZP06 ZP08 ZP10 ZP13 ZP16 ZP20 ZP25 ZP32 ZP40 ZP50 ZP63 ZP80 ZP100 ZP125 5 7 8 2 2 4 4 7 9 11 2 4 5 7 10 4 6 8 10 5 5 10 10 7 9 9 10 13 10 8 13 11 13 11 10 11 16 20 25 32 12 14 9 9 13 15 19 25 33 13 15 20 26 35 14 17 20 24 30 15 18 21 26 33 14 14 13 20 18 12 13 11 17
V 10 T = t x = 7.7 x = 77 (s). V 10 T = t x = 2.4 x = 24 (s). V 10 10 10 100 10 100 10 1012 Booster Regulator VBA Series VBA43A VBA11A Pulsation/Pulsation is decreased with a tank. If the outlet capacity is undersized, pulsation may occur.