View A PE L1 L2 L3 power supply cable Fig. 3-9 Wiring of power supply cable * Connect an over current protection to the power cable connected to the equipment to avoid hazard. 3.3 Installation HRL Series 3-16 HRX-OM-W060 Chapter 3 Transport and Setting Up 3.3.4 Contact input/output communicatin wiring Be sure to lock out and tag out the breaker of the facility power supply (the users machine
View A L1 L2 L3 PE Inlet of the power supply cable Mount for cable tie Note: Prepare a cable tie. Fasten the power cable to the mount on the base with the cable tie.
A control valve with cylinder speed control function and rapid air supply function Meter-out control ASS500 52.0 1/2, 3/4 55.0 580 ASS600 80.0 3/4, 1 90.0 950 ASS110 2.4 1/8 5.4 97 Meter-in control ASS310 16.5 1/4, 3/8 23.0 220 Specifications Air Fluid 0.7 MPa Max. operating pressure AS 5 to 60C (No freezing) Ambient and fluid temperature 0.1 to 0.5 MPa Set pressure ASP How to Order ASN 02
How to Order B LG1 02 1 Cable length 02 03 04 05 2m 3m 4m 5m Nonstandard Motor Cables Cables for connecting nonstandard motors and drivers. Cable lengths other than those shown below should be arranged by the customer.
PA03 02: LEC-MR-RB-032 03: LEC-MR-RB-12 Set this parameter to enable the absolute position detection system. For details, refer to "LECSN-T Operation Manual, Chapter 12.
Rc NPT G Nil N F OUT(2) 1 IN(1) Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Symbol 01 02 03 04 06 Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Orifice size Please consult with SMC regarding other voltages.
Nil N F Rc NPT G OUT 1 IN Port size Symbol 01 02 03 04 06 Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Voltage 1 2 3 4 36 100VAC 200VAC 110VAC 220VAC 230VAC Orifice size Consult SMC regarding other voltages.
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: L2 (IO-Link/Switch: 1 output + 2 outputs), Lead Wire: N (None)
Sensor Range: 6 [For Positive Pressure (0~5MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: L2 (IO-Link/Switch: 1 output + 2 outputs)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type])
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)
Mounting Method: 0 (1/4 Thread Connection), Load Capacity: 0 (Standard), Port Size: 02 (Rc(PT) 1/4), Indicator Light: L2 (Neon Lamp/220VAC), Pressure Display: P (MPa and psi)
Mounting Method: 0 (1/4 Thread Connection), Load Capacity: 0 (Standard), Port Size: 02 (Rc(PT) 1/4), Indicator Light: L2 (Neon Lamp/220VAC)
Power supply Single phase 200V AC (A type) or Single phase 100V AC (A1 type) MC NFB Servomotor HC-PQ C P U V W L1 U V Servo amp MR-CA or SM L2 E W MR-CA1 The cable length between the controller and servo amp is 2m or less. 24VDC Z CN1 EMG Note 7) Shuts off with alarm signal when servo ON is turned OFF.
(mm) Mounting screw L2 H2 D W1 H1 P L1 W2 W3 Model (Nominal x Length) 6 3.25 72.5 4.5 5.5 6 6.5 6.5 10 5 7.5 8 12 12 8 10 11 12 12 17 21 23 25 25 6 4 2.2 2.8 2.8 3.2 3.2 2 x 6 2.6 x 8 2.6 x 8 3 x 8 3 x 8 TM-04 TM-06 TM-08 TM-10 TM-12 7.5 9.5 91.5 5.5 77.5 6 7.5 77.5 6 15 9 93 12.5 6.5 4.5 16.3 8.8 14.3 7.5 12 12 10 8 9.8 How to Use 2.
. ## Description 00 Set to the test operation mode. 01 Station number 1 02 Station number 2 03 Station number 3 : : : : 62 Station number 62 63 Station number 63 64 Station number 64 Note 2. $$$ indicates numbers from 0 to 255, and the number indicates the executing point table number. 3. indicates the warning/alarm No. 4. Requires set up software(MR Configurator2TM) . -11- 3.
. ## Description 00 Set to the test operation mode. 01 Station number 1 02 Station number 2 03 Station number 3 : : : : 62 Station number 62 63 Station number 63 64 Station number 64 Note 2. $$$ indicates numbers from 0 to 255, and the number indicates the executing point table number. 3. indicates the warning/alarm No. 4. Requires set up software(MR Configurator2TM) . -11- 3.
(Tightening torque: 1.0 Nm) Terminal width 9.9mm PE L3 L2 L1 24 23 6 5 22 21 Remote operation Error signal Ground RUN signal Power supply (to be connected to the user's equipment) IDF190D/240D Series 3.2Installation 3-5 IDX-OM-Y002 Chapter 3 Transportation and installation 4) Mount the front panel back. [Remote control] Voltage of AC200V is present on the terminal block.
Sensor Range: 7 [For Positive Pressure (0~10MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: L2 (IO-Link/Switch: 1 output + 2 outputs), Lead Wire: N (None)