SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-N02-L2-K"

from Top of Auto Switch CLKG CKQ CLKQ 50 Safety distance L1 (mm) CK CLK 40 Operational range 30 CKQ L1 20 L1 Dangerous range 10 0 5000 10 15000 20 Welding current (A) 50 Safety distance L2 (mm) 40 30 L2 L2 Operational range 20 10 0 5000 10 15000 20 Welding current (A) D-X 439 CK1 Series Related Products Please contact SMC for detailed dimensions, specifications and lead times.

Model K VCKL0604-02F H KFN-06-X2 K VCKL0806-02F H KFN-08-X2 K VCKL1075-02F H L Union nut C3604BD + Ni plated 1 1 set unit KFN-10-X2 K VCKL1008-02F H K VCKL1209-02F H KFN-12-X2 K VCKL-02F H K VCKL0604-02F H KFS-06 K VCKL0806-02F H KFS-08 K VCKL1075-02F H M Sleeve Nylon 1 1 set unit KFS-10 K VCKL1008-02F H VNA VNB K VCKL1209-02F H KFS-12 SGC SGH N Gasket VCKK-4-1 Nylon 1 10 set unit VNC VNH

[Bottom mounting] B Pin hole L2 Pin hole D-X B = (0.045 + L2 x 0.0016) [mm] 437 MGP Series High Precision Ball Bushing/MGPA Plate Displacement Amount (Reference Values) Load from lateral direction Displacement MGPA12 MGPA32, 40 0.8 0.4 Plate displacement amount [mm] Plate displacement amount [mm] MGPA12-250 MGPA -400 32 40 0.7 0.35 0.6 0.3 MGPA -300 32 40 MGPA12-150 MGPA12-100 MGPA12-75

Nil D Standard type (1.0 W DC) 2 position double (Double solenoid specifications) Coil voltage (1) High pressure type (1.0 MPa, 1.0 W DC) [Applicable to metal seal only] K 5 6 24 VDC N Y R Negative COM 12 VDC (1) Low wattage type (0.5 W DC) Note) Light/Surge voltage suppressor is built-in. (2) External pilot specifications Note 1) Except double (latching) type.

Terminal SymName Specifications bols Main circuit power input terminals L1, L2 Single-phase 200 V to 230 V, +10% to -15% (50/60 Hz) L3*1 None 1.

Model K VCKL0604-02F H KFN-06-X2 K VCKL0806-02F H KFN-08-X2 K VCKL1075-02F H L Union nut C3604BD + Ni plated 1 1 set unit KFN-10-X2 K VCKL1008-02F H K VCKL1209-02F H KFN-12-X2 K VCKL-02F H K VCKL0604-02F H KFS-06 K VCKL0806-02F H KFS-08 K VCKL1075-02F H M Sleeve Nylon 1 1 set unit KFS-10 K VCKL1008-02F H K VCKL1209-02F H KFS-12 N Gasket VCKK-4-1 Nylon 1 10 set unit 23 Troubleshooting (Valve

Maximum load current: 80 mA Internal voltage drop: 1.5 V or less -23No.PF-OMY0002 PFMC7###-##-L3/L4#-### PNP type Maximum load current: 80 mA Internal voltage drop: 1.5 V or less L3: Analogue output: 1 to 5 V or 0 to 10 V Output impedance: 1 k L4: Analogue output: 4 to 20 mA Maximum load impedance: 600 Minimum load impedance: 50 PFMC7###-##-L2#-### PNP + External input type Maximum load

LVC DIN terminal: D Conduit terminal: T Cable 6 to 12 LVA F S Q 27.5 34 F (Q) LVH LVD LVQ LQ R C U 25 LVN C (44) R E R TI/ TIL G1/2 E PA G1/2 A H D (S) B B A H D 2-P Port size 2-P Port size PAX 2-M Thread depth N 2-M Thread depth N PB L L K K N.C.

K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R Q R Q R S Q R S 83 22 23 45 44 43 58 40.5 46.5 99 43 66 13.5 28 64 31

= 31 x n + 14 L L1 L2 1955 Power Valve: 3 Position Valve Series VEX3 Realize a variety of circuits using simple components.

(width across flats) Applicable tubing (mm) Effective area (mm2) Connection Weight (g) L4 d L2 L3 M A L1 Model thread R I.D.

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 70 87 104 121 138 155 172 189 206 223 240 257 274 291 308 325 342 359 376 393 410 427 L1 L2 (MP) L2 (AP) 195.5 212.5 229.5 246.5 263.5 280.5 297.5 314.5 331.5 348.5 365.5 382.5 399.5 416.5 433.5 450.5 467.5 484.5 501.5 518.5 535.5 552.5 215.5 232.5 249.5 266.5 283.5 300.5 317.5 334.5 351.5 368.5 385.5 402.5 419.5 436.5 453.5 470.5

element Drain cock D side Outlet for check Control unit n: Stations L Stations Formula 20n + 21 20n + 176 20n + 232.5 4 101 5 121 6 141 7 161 8 181 9 201 10 221 11 241 12 261 13 281 14 301 15 321 16 341 17 361 18 381 19 401 20 421 21 441 22 461 23 481 24 501 3 81 236 256 276 296 316 336 356 376 396 416 436 456 476 496 516 536 556 576 596 616 636 656 292.5 L1 L2 (MP) L2 (AP) 312.5 332.5

Cylinder: MXJ6-10 Cushion: Rubber stopper Mounting: Horizontal wall mounting Average speed: Va = 100 mm/s Load mass: W = 0.1 kg L2 = 40 mm L3 = 50 mm Model to be used Type of cushion Mounting orientation Average speed Va (mm/s) Load mass W (kg) Overhang (mm) MXU MXS L2 MXQ L3+A3 MXF Load Mass 2 MXW V = 1.4 Va Correction factor (Reference value) V = 1.4 x 100 = 140 Find the collision

VN K Conduit terminal: T LVC LVA F (Q) 34 LVH LVD LVQ 25 U LQ R C LVN G1/2 TI/ TIL E B A H D 2-P Port size (S) PA 2-M Thread depth N PAX L PB K N.C.

W W Mey Mep We We L3 A3 L2 A2 Note) Static moment : Moment by gravity Kinetic moment : Moment by stopper collision Max.allowable load:W max.

XMC Exterior dimensions C D L1 L2 Fn Fc C (Fc) (KF Flange) (CF Flange) J H B A G A Unit:mm Model A B C D Fn Fc G H J P.C.D L1 L2 XMC-16 40 110 38 1 30 34 17 40 26 P.C.D 27 6x4.4 XMC-25 50 120 48 1 40 26 39 28 XMC-40 65 171 66 2 55 70 41 63 36 P.C.D. 58.7 6x6.6 C D L1 L2 Fn Fd Fc C (Fc) (KF Flange) (K Flange) (CF Flange) H J K B A G A Unit:mm Model A B C D Fn Fc Fd G H J K P.C.D L1 L2 XMC-

17 18.5 17 26.5 10 23 K 25.0 35.2 1 2 KRL10-04S 37 63 28 38 22 Connection thread (With seal) 1 4 3 8 KRL12-02S KRL12-03S 35.5 37 M 17 24 39.7 50.2 17 28.5 1 2 KRL12-04S 20.9 39.5 65 12 22 H Reference dimensions after R thread installation.

Note 2) Assembly of a bracket and set nuts (90-AR30 and 90-AR40, 90-AR25(K) to 90-AR40(K)) Including 2 mounting screws for the 90-AR50(K) and 90-AR60(K). Note 3) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of 0.2 MPa or more. Note 4) : For thread type: NPT.

Brown Brown Load Load Switch 1 Switch 1 Blue Blue Brown Brown Switch 2 Switch 2 Blue Blue Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V Example: Load impedance is 3 k. Leakage current from switch is 1 mA. Power supply Residual Load voltage at ON = voltage voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Example: Power supply is 24 VDC.