Pressure Range: 0 to 5 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: Orifice shipped with the Product, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: Orifice shipped with the Product, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: Orifice shipped with the Product, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: None, Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: Orifice shipped with the Product, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: Orifice shipped with the Product, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

Pressure Range: 0 to 5 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

Pressure Range: 0 to 5 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms) Yes 0.2% F.S. 1 digit Push Push Push Push Push Push Finish setting Adjust to set-value with buttons.

[mm] Overhang: L2 [mm] Overhang: L2 [mm] Overhang: L2 [mm] 160 160 L2 120 120 80 80 40 40 Horizontal mounting Wall mounting 0 0 0 0.44 0.88 0.32 1.76 2.2 0 0.44 0.88 0.32 1.76 2.2 0.0 0.88 1.76 2.64 3.53 4.4 0.0 0.88 1.76 2.64 3.53 4.4 Work load [lb] Work load [lb] Work load [lb] Work load [lb] 200 200 200 200 Overhang: L3 [mm] Overhang: L3 [mm] Overhang: L3 [mm] Overhang: L3 [mm] L3 160

NARM 2500 05 A 02 G1 Optimal for central pressure control. Accessory Regulator for manifold Pressure easily set using the new handle. One-touch lock system.

VE 3 Bleed port Model (Made to Order) Pressure range Note) Indication unit Connection thread VY1 Note Model MPa G43-2-01 to 02-X2 G43-4-01 to 02-X2 G43-6-01-X2 G43-7-01 to 02-X2 G43-10-01 to 02-X2 G43-2-01 to 02-X3 G43-4-01 to 02-X3 G43-6-01-X3 G43-7-01 to 02-X3 G43-10-01 to 02-X3 G43-2-01 to 02-X4 G43-4-01 to 02-X4 G43-6-01-X4 G43-7-01 to 02-X4 G43-10-01 to 02-X4 0 to 0.2 0 to 0.4 0 to 0.6

Output 1 Output 2 A B C Dimensions D3 D2 L5 M2 IN L3 L2 L4 OUT IN D1 M1 M1 Applicable tube dia. d L1 Metric Size Weight (g) Model d D1 D2 L3 L2 D3 L1 L4 L5 M1 M2 VR1211F-23 3.2 11.4 8.4 52 6.2 25.7 36.1 17.5 12.7 12.9 26.4 14.8 VR1211F-04 4 12.8 10.4 56 26.6 38.5 21.9 15.7 15.8 30.4 6.8 VR1211F-06 6 12.8 12.8 53.2 28.8 41.9 25.2 16.8 16.8 25.0 Inch Size Weight (g) Model d D1 D2 L3 L2 D3 L1