(mm) mm Flow rate coefficient Max. system pressure (MPa) (1) Port size Weight (g) Cv Water Air Model AC DC AC DC AC DC Effective area (mm2) 34 10 1.9 600 10 VXZ2232-02 0.7 0.6 0.7 0.6 0.7 0.6 1 4 1 4 10 43 2.4 600 10 VXZ2232-03 0.7 0.6 0.7 0.6 0.7 0.6 3 8 3 8 . 0.7 VXZ2242-04 0 1.5 15 95 5.3 850 15 0.7 0.6 0.7 0.6 0.6 1 2 1 2 165 20 9.2 1,370 20 VXZ2352-06 0.7 0.6 0.7 0.6 0.7 0.6 3 4 3 4
Applicable dryer Capacity Model Inlet voltage Outlet voltage A B C D E F Weight (kg) 200, 220 230, 240 VAC (50 Hz) 200 to 260 VAC (60 Hz) 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase Single turn IDF-TR500-2 IDF1E-10 to 8E-10 IDU3E-10, 4E-10 500 VA 118 140 150 70 112 142 6 IDF-TR500-3, 4 C VOLUTAGE SELECTOR FUSE B OUT PUT IN PUT E D 4-F A Input cord 2 m Transformer part no.
Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to
/8 NPT1/8 75, 100 56.5 39.5 10 to 50 50.5 30.5 50 10.5 10.5 G1/4 60.5 40.5 10.5 10.5 64 62 53.4 Rc1/4 NPT1/4 NPT1/4 Rc1/4 NPT1/4 NPT1/4 G1/4 75, 100 60.5 40.5 HA NN NN OA Bore size (mm) 32 40 50 V W HB IA IB J KA KB L M N OB RA RB S U Z , TN, TF , TN, TF 38 10 5 60 58.5 4.5 28 19.8 7 34 5.5 9 7 58.5 31.5 10 M5 x 0.8 10-32UNF M6 x 1.0 1/4-20UNC 14 46 10 5 69 67.5 5 33 23.3 7 40 5.5 9 7 66
COM 10 LZR 9 6 LB B phase pulse detector (Differential line driver) LG 3 7 LBR Control common SD Plate 34 LG Control common 10 m or less Note 5) 33 OP Z phase pulse detector (Open collector) 1 P15R Plate SD 10 m or less 2 m or less Note 4) CN1 EMG Emergency stop 42 SON 15 Servo ON CN6 Note 4) RES 19 Reset 3 MO1 PC 17 Proportion control Analog monitor 1 10 VDC 1 LG TL 18 External torque limit
Example) M5 x 75l (MK2B) MK232/40 10 2 ML2B 6 Moment of inertia (kgm2) C J G5-S 4 MK220/25 CV 2 Mounting bolt 10 3 MVGQ 6 CC 4 Flat washer Operating range RB 2 Note) Be sure to use a flat washer to mount cylinders via through-holes. 10 4 J Model C D 75 85 80 90 90 100 80 90 105 135 105 135 Mounting bolt M5 x 75l M5 x 85l M5 X 80l M5 x 90l M5 x 90l M5 x 100l M5 x 80l M5 x 90l M6 x 105l M6
/min. (28 LPM) RECOMMENDED FILTRATION 5 micron Model Number Description V-800-10-W/K 0-10" Hg Vacuum regulator with adjusting knob V-800-10-W/S 0-10" Hg Vacuum regulator with 1/4" adjusting shaft V-800-10-W/OS 0-10" Hg Vacuum regulator with slotted adjusting shaft V-800-30-W/K 0-30" Hg Vacuum regulator with adjusting knob V-800-30-W/S 0-30" Hg Vacuum regulator with 1/4" adjusting shaft V-
CY1H25 (Nm) 64 56 50 40 30 50 40 M1 1.5 10 13 M2 2.5 16 16 M3 1.5 10 13 M1 28 56 64 M2 26 85 96 M3 28 56 64 Model CY1H25 CY1HT25 CY1HT32 Model CY1H10 CY1H15 CY1H20 30 28 26 20 20 CY1H20 CY1H15 16 13 Moment Nm Moment Nm 10 10 2 2.5 3 4 5 3 4 5 CY1H10 M3 2 CY1H10 1.5 1 1 0.5 0.5 70 100 300 500 100 300 500 1000 1000 70 M1 M2 Piston speed mm/s Piston speed mm/s Graph (3) Graph (2) Moment generated
Overcurrent protector 10 A 14 A Current consumption 5 A (100 V) to 2.5 A (240 V) 9 A (100 V) to 4 A (240 V) 10 A (100 V) to 4 A (240 V) 8 A (200 V) Power consumption 440 W*1 850 W*1 900 W*2 1500 W*2 Alarm Refer to Alarm.
L1 0 10 30 20 Transfer load m (kg) 300 L2 200 Mer m 100 L2 0 10 30 20 Mer Transfer load m (kg) m 300 a = 500 a = 1000 200 a = 2000 L3 100 m Mey a 0 10 30 20 Transfer load m (kg) Refer to page 145 for deflection data. 92 Standard Motor/Horizontal Mount Specification Series LJ1S30 Dimensions/LJ1S303SC Scale: 10% 8H10 depth 10 4-M8 x 1.25 thread depth 10 120 4-M12 x 1.75 thread depth 15 20
Applicable shaft types: S, W E3 = LL LL E1 = Key L1 = X = L3 = (mm) (mm) Key dimensions 4 x 4 x 20 4 x 4 x 20 5 x 5 x 25 LL 3 4 5 Size 20 30 40 X 8 to 18 10 to 20 L1 {10 (18 X)} to (X 2) {10 (20 X)} to (X 2) Size 10 15 L3max X-2 X-2 11-8-15 16 Series CRQ2 (Size: 10, 15, 20, 30, 40) Simple Specials: -XA31 to -XA46: Shaft Pattern Sequencing II Shaft shape pattern is dealt with simple
10 10 10 10 10 58 70 87 NN 2 2 2 2 3 4 5 6 7 H 45 45 45 55 35 35 35 38 44 G 15 15 15 15 15 19 37 41 19 N 4 4 4 4 6 6 6 8 8 HA 35 35 35 35 35 70 70 76 88 NA 2 2 2 2 2 2 4 4 4 FF 40 40 40 50 35 60 70 70 80 GA 25 25 25 35 50 54 107 155 195 KA 169 223 275 13-/22-MXS20L-10 13-/22-MXS20L-20 13-/22-MXS20L-30 13-/22-MXS20L-40 13-/22-MXS20L-50 13-/22-MXS20L-75 13-/22-MXS20L-100 13-/22-MXS20L-125
/Y7PV D-Y7WV 10 + 30 n = 2, 4, 6, 8 (n 2) 2 100 + 30 n = 4, 8, 12, 16 (n 4) (n 4) (n 4) 2 90 + 30 n = 4, 8, 12, 16 2 95 + 30 n = 4, 8, 12, 16 n 2 2 (Different sides, Same side), 1 115 130 20 120 125 n D-Y7BAL 20 + 45 n = 2, 4, 6, 8 (n 2) 2 (n 4) (n 4) (n 4) (n 4) 2 115 + 45 n = 4, 8, 12, 16 120 + 45 n = 4, 8, 12, 16 125 + 45 n = 4, 8, 12, 16 130 + 45 n = 4, 8, 12, 16 2 2 2 6-9-8
-/21-CM2R20 10-/21-CM2R25 10-/21-CM2R32 10-/21-CM2R40 11-/22-CM2R20 11-/22-CM2R25 11-/22-CM2R32 11-/22-CM2R40 25, 50, 75, 100, 125, 150 Relief type Vacuum suction type 1/8 25, 50, 75,100, 125, 150, 200 1/4 Not available 25, 50, 75, 100, 125, 150, 200, 250, 300 Non-lube Double acting, single rod Available Available 25, 50, 75, 100, 125, 150 1/8 25,50,75,100,125,150,200 1/4 25,50,75,100,125,150,200,250,300
Cooling Capacity HRSH100-A-20/40HRSH100-W-20/4014 16 Ambient temperature 32C Facility water temperature 32C 14 12 Cooling capacity [kW] Cooling capacity [kW] 10.5 10 11.5 12 10 Ambient temperature 43C 8 8 Facility water temperature 40C 6 6 Ambient temperature 45C 4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH150
Flow Rate and Effective Area JIS symbol AS1001F AS2001F AS3001F AS2051F AS4001F Model Metric sizes 10, 12 8 6 6 8 6 12 10 3.2, 4, 6 4 Tubing O.D. 1/8, 5/32 3/16, 1/4 3/8 5/16 3/16, 1/4 1/4 3/16 1/4, 5/16 1/2 Inch sizes 3/8 5/32 Flow rate l/min (ANR) {Nl/min} 920 660 230 420 1390 290 460 1050 100 130 Controlled (Free) Effective area mm flow 14 10 3.5 6.5 21 4.5 7 16 2 1.5 1l/min=0.035SCFM
Load weight Allowable moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
35 to 100 75 to 200 75 to 300 5 to 30 5 to 30 5 to 50 5 to 50 Bore (mm) 12 16 20 25 RR CZ CX CW CU CT CD 6 6 9 10 10 12 16 20 5 6.5 8 10 14 15 18 20 7 10 12 14 4 4 5 5 5 5 8 10 * Refer to P.2.3-18 for detail of the rod end nut and mounting brackets.
4 Cushion valve Top width across flats 4 10 13 30 3 x Rc3/8 (Piping port) 14 10 Width across flats 100 43 10 27 3 x Rc3/8 (Piping port) 77.5 45 45 M24 x 1.5 44 112 30 Max. 65 Max. 65 50 52 R24 Hole: 18 +0.027 0 Width across flats 24 4 x M6 Thread depth 12 28 +0.5 +0.1 Shaft: 18 0.050 0.093 61 129 + Stroke 110 85 259 + Stroke Please contact SMC for details of the CKGA/CKPA series. 442 Related
Ambient and fluid temperature (C) Response time (ms) (1) 10 to 50 (No freezing. Refer to page 4-18-4.) 15 or less Applicable for vacuum use 100 kPa Max. operating frequency (Hz) 15 Flow Characteristics Refer to the table below.