Series NCJ2 miniature cylinders available in spring return, spring extend, or double acting all offer stainless steel tubing and stainless steel rods. Available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Basic, foot, front flange and double rear clevis mounting options. Auto-switch capable. Other features include non-rotating, double rod, rubber bumpers and a stainless
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 5", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Magnet: Built-in Magnet, Series: Standard, Head Cover Type: Double End Boss-cut, Bore Size: 32mm, Stroke: 200mm, Action: Single Acting, Spring Return, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: Band Mounting
Motor: 2-Phase Stepping Motor, Thread Lead: 2mm, Stroke: 200mm, Origin Switch: Yes (Cable Length 0.3m), Brake: No, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Number: 2 pcs.
Motor: 2-Phase Stepping Motor, Thread Lead: 2mm, Stroke: 200mm, Origin Switch: Yes (Cable Length 0.3m), Brake: No, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Number: 3 pcs.
Motor: 2-Phase Stepping Motor, Thread Lead: 2mm, Stroke: 200mm, Origin Switch: Yes (Cable Length 0.3m), Brake: No, Auto Switch: M9BL--Solid State, Gen. Purpose, 2 Wire, Horizontal, 3M, Number: 2 pcs.
Motor: 5-Phase Stepping Motor, Thread Lead: 5mm, Stroke: 200mm, Origin Switch: Yes (Cable Length 0.3m), Brake: No, Auto Switch: M9BL--Solid State, Gen. Purpose, 2 Wire, Horizontal, 3M, Number: 2 pcs.
Motor: 2-Phase Stepping Motor, Ball Screw Lead: 6mm, Stroke: 200mm, Home Position Switch: Yes (Cable Length 0.3m), Brake: None, Auto Switch: M9NL--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 3M, Number: 2 pcs.
Motor: 5-Phase Stepping Motor, Ball Screw Lead: 12mm, Stroke: 200mm, Home Position Switch: Yes (Cable Length 0.3m), Brake: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Number: 2 pcs.
Motor: 2-Phase Stepping Motor, Ball Screw Lead: 6mm, Stroke: 200mm, Home Position Switch: Yes (Cable Length 0.3m), Brake: None, Auto Switch: M9PL--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 3M, Number: 1 pc.