> [F 2] [F 1] OUT1(2729) 1[-], [F 3] <> [F 3] [F 3] -30No.PS-OML0002CN-G [F 4] <> [F 4] 1000 100 [F 4] [MPa]/[kPa(ZSE)]/[kgf/cm 2]/[bar]/[psi]/[inHg] ([kgf/cm 2]/[bar]/[psi]/[inHg] 26[F 0] -31No.PS-OML0002CN-G [F 5] <> [F 5] [F 5] -32No.PS-OML0002CN-G OUT1 AP1 (OUT1AP1 1AP2) OUT1 OUT1 OUT1 A1L A1H (A1L 1AP2) OUT2 P_1 H_1(n_1 H_1)AP2 (OUT2AP2 1 ) OUT2 OUT2OUT1OUT2

Note 4) Except valves. 581 A 5 Port Solenoid Valve/Plug-in Unit 10-SQ1000 Kit (D-sub connector) F Directional Control Valves Air Grippers Modular F. R.

CKGA80, 100/CKPA80, 100/With Magnetic Field Resistant Auto Switch (Rod Mounting Type) 1 P3DWASC CK G A 80 Y Built-in standard magnet type with magnetic field resistant auto switch 100 Built-in strong magnet type with magnetic field resistant auto switch 100 P79WSE CK P A 80 Y Built-in standard magnet Number of auto switches Nil S 2 pcs. 1 pc.

Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.

Bore size System Average speed [mm/s] MB, CA2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 500 mm 40 50 63 80 100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal A 1000 900 800 700 600 500 400 300 200 100 0 B 1000 900 800 700 600 500 400 300 200 100 0 C Bore size System Average speed [mm/s] CS1/CS2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 300 mm 125 140 160

Round Type Low Pressure Hydraulic Cylinder Series CHM 20, 25, 32, 40 3.5MPa How to Order CHM 25 100 L L With Auto Switch CHDM 25 100 C73 With auto switch (built-in magnet) Number of auto switches Nil S n 2 pcs. 1 pc. "n" pcs.

N.O. 1 (P) 3 (R) 1 (P) 3 (R) a c e d a c e d (A) (A) 2 2 g g 3 (R) 1 (P) 3 (R) 1 (P) b b f f Component parts Replacement parts Note Zinc die-casted No.

0] [F] 2 2 [-] [F 0] 27 ISE40A MPa ""M ZSE40A(F) kPa ISE40A P ZSE40A(F) psi [[F 1] OUT1 28 ONOFF ISE40A0.500 MPa ZSE40A-50.7 kPa ZSE40AF50.0 kPa ISE40A0.050 MPa ZSE40A5.1 kPa ZSE40AF5.0 kPa ON OFF [F 2] OUT2 31 [F 1]OUT1 OUT1 -25No.PS-OMM0006CN-E [F 3] 33 2.5 ms [F 4] 34 [F 5] / 36 [F 6] 38 0 [F11] 39 1000 [F80] 40 OFF [F81] 41 OFF [F90] 42 OFF [F97] 44 OFF [F98] 46 [

SY11 A 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0 0.22 100 kPA to 0.6 Large flow 0 to 0.7 N.C. SY13(A): 15 SY14(A): 26 (14) SY13(A): 13 SY14(A): 24 (12) (1) SY12 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0.6 0.14 100 kPA to 0 Standard 0 to 0.7 N.O. (1) SY12 A 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0.6 100 kPA to 0 0.22 Large flow 0 to 0.7 N.O.

Connection Port CRBU2W10 CRBU2W15 CRBU2W20 CRBU2W30 90 CRBU2W40 90 Vane type Model (size) 180 270 90 180 270 90 180 270 90 180 270 180 270 Rotating angle Single vane Double vane Volume (cm3) 1.2 1.5 2.9 3.7 6.1 7.9 15 20.2 25 31.5 41 1(0.6) 1.5(1.0) 4.8(3.5) 11.3(8.5) Side ported M5 x 0.8 Port size Axial ported M5 x 0.8 M3 x 0.5 90 100 90 100 90 100 90 100 90 100 Rotating angle Volume (cm

(Note: Reed auto switches for 100 VAC and 100 VDC are not within the specification.

A F FKM EPR 32 to 50 come in valve element assembly 4 material Pilot solenoid valve SF4--23 (Refer to the table below.)

(Station 1) Light/surge voltage suppressor Side A: Orange Side B: Green (7.5) 43.5 Internal pilot manifold L: Dimensions n: Stations External pilot manifold L: Dimensions n: Stations L n 2 98 87.5 70 14 L n 2 110.5 100 80.5 15 3 110.5 100 80.5 15 4 123 112.5 91 16 5 135.5 125 101.5 17 6 135.5 125 112 12 7 148 137.5 122.5 13 8 160.5 150 133 14 9 173 162.5 143.5 15 10 185.5 175 154 16 3 123

20 10 0 100 Suction flow [L/min(ANR)] Air consumption [L/min(ANR)] Vacuum pressure Vacuum pressure [kPa] Vacuum pressure [kPa] 80 60 Suction flow 40 20 Air consumption 0 0 10 20 30 40 Supply pressure [MPa] Suction flow [L/min(ANR)] ZHP-10 ZHP-10 (Supply pressure: 0.35 MPa) 100 90 80 70 60 50 40 30 20 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6 100 90 80 70 60 50 40 30 20 10 0 100 Suction flow [L/min(

22 80 120 189 C F E Breathing port M5 x 0.8 J Integral ttings/LQ1 4 x 7 Mounting hole 1/8 (Rc, NPT) Pilot port A H D B G Model A B C D E LVR20-V07(06) 40 40 49.3 68 20.1 LVR40-V11(10) 82.5 82.5 89 115 33 LVR40-V13(12) 82.5 82.5 89 115 33 LVR50-V19 100 100 117.5 135 45 Breathing port M5 x 0.8 IN Model F G H J LVR20-V07(06) 8 27 56 77 LVR40-V11(10) 14 64.5 100 140.5 LVR40-V13(12) 14 64.5 100

100 200 1 0.5 30 0.5 0.8 Provide requisite conditions for selection.

Basic Rc(PT)P Rc(PT)P GA H2 NN NN GB H1 MM I ND D NB NE C Effective Thread E E NF N JC 10 10 N JD A K F NA S+Stroke F H B WH ZZ+Stroke (mm) Stroke range (mm) 200 to 700 200 to 700 200 to 1000 200 to 1000 Bore (mm) 20 25 32 40 Eff. thread length 15.5 19.5 19.5 21 H1 5 6 6 8 H 44 48 51 54.5 GB 47.5 49.5 51.5 51.5 GA 53.5 56.5 55 56 F 16 16 19 21 E 14.5 18 18 20.5 D 10 12 12 16 C 40.5 45.5 51.5

4/5 Port Air Operated Valve SYJA3000 Series How to Order Bracket With bracket F Nil Without bracket *Refer to page 1475 for the details of the brackets.

120 140 0 1 3 24 32 36 63.5 75.5 88 to 1000 to 1000 to 1000 Front flange type (F) 4-FD FY B FT FX (mm) FZ Stroke range Bore size (mm) B FT FD FX FY FZ 40 50 63 12 16 16 80 100 112 58 61 75 100 125 138 9 9 12 74 78 100 to 1000 to 1000 to 1000 Rear flange type (G) 4-FD FY B FX FT ZZ + Stroke FZ (mm) Stroke range Bore size (mm) B FT FD FX FY FZ ZZ 40 50 63 12 16 16 80 100 112 58 61 75 100 125